ABP – Hadron Sources & Linacs

ABP – Hadron Sources & Linacs. R Scrivens ABP Group Meeting 19/06/2013. Personnel. REX ISOLDE. Excellent performance, with 15 new isotopes delivered including the lightest so far – 6He – and polarized 8Li. Pear shaped nucleus discovered.

abra
Download Presentation

ABP – Hadron Sources & Linacs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ABP – Hadron Sources & Linacs R Scrivens ABP Group Meeting 19/06/2013

  2. Personnel

  3. REX ISOLDE • Excellent performance, with 15 new isotopes delivered including the lightest so far – 6He – and polarized 8Li. • Pear shaped nucleus discovered. • Study underway for an EBIS charge breeder with a higher electron current and voltage. Includes tests on a BNL high current gun design in Brookhaven. L. P. Gaffney, P. A. Butler, M. Scheck, A. B. Hayes, F. Wenander, et al, Nature.

  4. REX ISOLDE - future • Repair work and some tests for different EBIS cathodes. • HIE-ISOLDE is under construction, meaning no beam to “REX” until 2015! • TSR – Study is being made to bring this Heidelberg Storage ring to CERN (to be installed after HIE-ISOLDE).

  5. Linac4 - source • New source and extraction system was installed at the 3MeV test-stand. • Once recoupled to the DESY designed plasma generator, H- could be extracted at 45keV for the first time. • So new extraction system and pulsed HT shown to work even for very high electron currents.

  6. Linac4 - source • Cesiation of the new source to be commissioned at the test stand. • Second source to be made operational in the Linac4 tunnel.

  7. Linac4 – Beam Commissioning • Beam though the RFQ on 13/03/2013. • Validation of RFQ, diagnostics and chopping. 3 MeV beam slit-SEMgridemittance measurement First beam through the RFQ: 10mA H- accelerated at first shot Chopped beam Beam chopper tests Beam deflection on wire-scanner

  8. Linac4 – Beam Commissioning • Drift Tube LinacPermenantQuadrupoles up to 25 T/m – All now delivered to CERN. • Moveable test bench for beam measurements at 50 and 100 MeV has been defined. Includes emittance measurement with multiple profiles.

  9. Linac4 – Overall Planning

  10. Linac2+3 • Linac2 worked like a Swiss Watch. • Both Linacs serving p->Pb LHC run, L3 for Pb NA61. • Linac3 startup was very difficult, a lot of controls renovation lessons learned. • Linac3 has been tested with argon, NAr~6e9 / pulse ~ 10xNPb. • A lot of information e.g. neutrons produced in Linac3, Ar plasma aggressive in the source.

  11. Linac2+3 • Both Linacs now in LS1. Restart planning to be done. • Linac2 • New access system. • A lot of critical controls being renovated. • Instrumentation being changed for Linac4 versions. • New source controls to be implemented. • Restart of source in April 2014. • Linac3 • New stripper. • Low energy emittance measurement. • Restart beam in 2014 for a long Ar injector setup and physics run (into 2015).

  12. Its been a good year, and the last 6 months in particular have seen a lot of highlights -> thanks to great spirit and determination. • The low energy machines have produced new beams and new physics, and there are plenty of facilities to create. • Ion for BioLEIR • H- / p+ source for ELENA