Air Circuit Breakers

BCH Electric Limited is committed to achieve a leadership position in the electrical switchgear, control gear and automation industry by creating a technical and marketing advantage to consistently meet and exceed customer expectations.

bchindia
Download Presentation

Air Circuit Breakers

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WelcometoBCH ELECTRIC LIMITED www.bchindia.com

  2. Air Circuit Breakers The unique “Double Break” main contact system ensures extremely fast interruption of short circuit currents and substantially reduces main contact wear. The internally symmetrical “Double Break” structure allow reverse power connection. This is the only ACB with this facility in India Very fast interruption by Double Break system

  3. No extra arc space required, vertical stacking permitted No extra arc space The TemPower2 ACB dissipates all arc energy within its unique “Double Break” arc chamber. This internal energy dissipation  allows the clearance distance between  the ACB  and  nearby earthed metal to be zero  minimizing switchboard height and costs. Releases

  4. TemPower2 provides positive protection for electric power systems. The TemPower2 series comes equipped with  RMS sensing over-current releases (OCR) offering a wide range of protection functions and capabilities.

  5. * L-Characteristic general feeder circuits protection * R- Characteristics general feeder circuits protection * Generator  protection Protection features Standard * Long time delay * Short time delay * Instantaneous (Optional) * Ground fault * Reverse Power trip * N-phase protection * Earth leakage * Two channel pre trip * Advance LCD display * Contact temperature monitoring * Communication protocol TemPower2 Air Circuit Breakers Double Break System : Two Steps ahead

  6. TOLL FREE : 1800-103-9262 Fax : 91 11 23715249 CORPORATE OFFICE :  1105,New Delhi House,27,Barakhamba Road, New Delhi - 110 001 91 11 23316029 / 3610 / 6539, marketing@bchindia.com  CONTACT US :- Thank You www.bchindia.com