1 / 13

Vacancy clusters in self-ion implanted Germanium studied with PALS

Vacancy clusters in self-ion implanted Germanium studied with PALS . Ryan Weed Centre for Antimatter-Matter Studies. Beamline overview. Beamline overview. detector. Source. Sample station. Transport coils. Trap. Pals analysis. PALS analysis. Motivation.

dallon
Download Presentation

Vacancy clusters in self-ion implanted Germanium studied with PALS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vacancy clusters in self-ion implanted Germanium studied with PALS Ryan Weed Centre for Antimatter-Matter Studies

  2. Beamline overview

  3. Beamline overview detector Source Sample station Transport coils Trap

  4. Pals analysis

  5. PALS analysis

  6. Motivation • Germanium is a good candidate to replace Silicon in CMOS devices • 3-4 times higher mobility (determines device speed)

  7. Motivation • Implantation induced defects effect electrical activation • Dopant-defect relationship not well understood in Ge • Diffusion mechanisms dissimilar to Si • Positrons well suited to study evolution of vacancy type defects under thermal treatment

  8. Ion implantation • 800 keVGe+ implantation • Fluence between 3x1012 and 3x1014 cm-2 • Vacancy and interstitials damage distribution simulated in SRIM

  9. RBS results

  10. RBS results As-implanted Annealed • High fluence sample ‘amorphized’ by ion implantation • No damage detected in low fluence sample • SPEG of amorphous region complete at 400 C anneal

  11. PALS results • Vacancy clusters formed in both samples • Cluster size expected in magicnumbers (N=6,10,14) • Clusters dissolve at 500 C in both samples

  12. Variable energy PAls • 2,10,18keV positron energies performed on 400 C annealed samples • Similar lifetime distribution for amorphous and sub-amorphous implants • Intensity distributions differ • Mobility differences or SPEG effect

  13. Thanks CAMS – James Sullivan, Steve Buckman, Michael Went, Jason Roberts EME – Simon Ruffell Technical Staff - Steve Battison, Ross Tranter, Colin Dedman, Graeme Cornish PPC10 organizers for help in financing my attendance