1 / 29

Revenue accuracy in an advanced power quality analysis meter

Revenue accuracy in an advanced power quality analysis meter. PowerLogic ™ ION7550/ION7650. ION7550/ION7650 meters are part of a complete PowerStruxure solution. Integrate with StruxureWare Power Monitoring software Help engineering and management personnel meet operational goals:

Download Presentation

Revenue accuracy in an advanced power quality analysis meter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Revenue accuracy in an advanced power quality analysis meter PowerLogic™ ION7550/ION7650

  2. ION7550/ION7650 meters are part of a complete PowerStruxure solution • Integrate with StruxureWare Power Monitoring software • Help engineering and management personnel meet operational goals: • Improve efficiency and cut energy-related costs • Assure reliability and reduce downtime • Optimize equipment utilization and reduce the cost of operations More on PowerStruxure at the end of the presentation….

  3. ION7550/ION7650 meters help enable PowerStruxure solutions with… • Unmatched functionality • Advanced power quality analysis • Revenue accuracy • Multiple communications options • Web compatibility • Control capabilities • Trending and forecasting • Disturbance direction detection • Choice of display options • Integral, high-visibility backlit LCD with adjustable contrast • Separately-mounted, color touch screen backlit LCD with wide viewing angle Integrate with your existing wholesale settlement system, use StruxureWare Power Monitoring software, or share operations data with existing SCADA systems Customize metering or analysis functions without any hard-wiring

  4. Revenue metering accuracy in a Class A power quality meter! • Meets IEC and ANSI accuracy measurement standards • IEC 62053-22 Class 0.2S • ANSI C12.20 0.2, Class 10 & 20 • Measures according to IEC 61000-4-30 Class A Edition 2 (power quality parameters) • Measures flicker (IEC 61000-4-15) • Monitors power quality compliance (EN50160 – ION7650 only) • Multi-user, multi-level security provides read-access rights to administrative rights for up to 16 designated users

  5. Choice of high-visibility display options • The ION7550/ION7650 meter’s intuitive, integral display features a high visibility 87 x 112 mm backlit LCD with adjustable contrast • The 86 x 115 mm color, remote-mounted LCD is touch screen operated and communicates to the meter via serial or Ethernet • Languages include English, French, and Spanish; User-configurable IEC or IEEE notations; 12/24 hour clock support in multiple date/time formats.

  6. Gateway functionality • Can act as a gateway when the Ethernet port and/or modem options are present • Modbus Master allows front panel display of real-time parameters from any downstream Modbus devices. EtherGate ModemGate Telephone line Ethernet Serial Serial • EtherGate: access via Ethernet port and ModbusTCP to daisy-chained Modbus devices connected to the meter’s serial ports • ModemGate: access from telephone network to devices connected to the meter’s serial ports

  7. Modular, flexible ION architecture • Use StruxureWare Power Monitoring software to leverage the meters modular, flexible ION architecture for extensive customization • Uses simple “building block” approach • Uniquely addresses advanced monitoring and control applications • Adapts to changing needs, avoiding obsolescence

  8. Front panel features High visibility display screen Softkeys Navigation buttons PROG/SELECT buttons Operational LEDs ANSI optical port

  9. Rear connection features Voltage/Current Inputs Analog Outputs Analog Inputs Digital Inputs Ground Terminal Power Supply Form A Digital Outputs Form C Digital Outputs Digital Inputs

  10. Communications features RS-232 RS-485 Ethernet 10BASE-T/100BASE-TX ANSI type 2optical port (front panel) Modem (if equipped) Fiber (100BASE-FX)

  11. List of features

  12. List of features

  13. Validate power quality with the energy contract Verify reliable equipment operation Improve response to power quality-related issues Allocate energy costs to departments or processes Reduce peak demand surcharges, power factor penalties Participate in load curtailment programs Identify billing discrepancies Augment energy rate negotiations Enhance substation automation Leverage existing infrastructure Integrate with other utility metering systems Metering Applications

  14. Validate power quality • Analyse power quality, including harmonics, disturbances • Sag/swell monitoring: report on disturbance magnitude and duration • Analyse disturbances to determine direction relative to meter • Power quality results comply with EN50160 standard (ION7650 option) • Certified to IEC61000-4-30 Class A Edition 2 (ION7650) • Compare monthly results with energy contract to determine compliance

  15. Verify reliable equipment operation • Optimize configuration of power distribution equipment • Compare load characteristics to confirm correct connections, proper operation • Audit real-time and historical data • Reveal relationships between equipment and other system factors • Evaluate, document risks

  16. Improve response to power quality-related issues • Collect data from key points across substations or facilities • Display power quality-related conditions, alert personnel to issues • Track disturbances, isolate problem sources • Confirm the proper operation of equipment such as transient voltage surge suppressors • Eliminate manual labor involved in tracking UPS capacities and operations

  17. Allocate energy costs to departments or processes • Track energy costs to cost centers, identify demand control opportunities, check energy consumption patterns, verify bills • Track system-wide power factor, demand peaks, penalty tariff structures • Revenue-class certified • MV-90 support and multi-year scheduling with hourly activity profiles

  18. Reduce peak demand surcharges, power factor penalties • Avoid penalties with automated: • Load shedding Peak shaving • Scheduling Capacitor bank control • Measure block, rolling block and predicted demand • Measure on any instantaneous value; records peak and minimum

  19. Participate in load curtailment programs • Evaluate feasibility of program participation: deliver load profiles, forecast and analyse costs • Determine where, quantity of load reduction in response to curtailment requests • Automatically shed loads, start up generators to coordinate curtailment strategies

  20. Identify billing discrepancies • Use collected energy data to compare and reconcile with supplier energy data • Validate compliance with energy contract terms • Identify and reconcile penalty charges (i.e. large peak demand surcharge for increased power draws) • Capture all event information to validate charges

  21. Augment energy rate negotiations • Make informed procurement decisions, manage multiple supply agreements • Collect detailed energy consumption data, energy-relevant information • Study historical load profile data, forecast energy needs, analyze alternate utility rate structures • Perform “what-if” analyses to identify the most favorable tariffs

  22. Enhance substation automation • Improve process yields and extend equipment life • Analog and digital I/O enables systems monitoring and control • Set alarms to warn of pending problems • Base maintenance schedules on operating history • Log events and alarms for all critical conditions • IEC 61850 protocol support to ease integration with SCADA

  23. Leverage existing infrastructure • Assess overall efficiency, reliability of electrical system • Determine capacity of electric network, run at peak efficiency • Displays, trends, and continuously updates historical data - up to four parameters simultaneously • Integrates with on-site generation; use to implement load shedding

  24. Integrate with other utility metering systems • Collect, scale, and log water, air, gas, electricity, and steam readings from connected meters or transducers • Deliver this information to head-end systems

  25. Maximize the efficiency and reliability of your power network PowerSTruxure solutions

  26. PowerStruxure solutions deliver real-time, relevant, and actionable information precisely when and where you need it

  27. PowerStruxure exceeds traditional power management • PowerStruxure is an extensive, advanced family of electrical distribution solutions that combine: • Power monitoring and control software • Systems designed to help you stay on top of real-time conditions, isolate problems, study trends, control loads and generators • Communication devices and protocols • At the heart of our PowerStruxure solution, they link the software with your power network hardware • World-class hardware • A wide, deep range of products that includes intelligent metering devices, switchgear, circuit breakers, protection relays, power factor correction equipment

  28. A PowerStruxure solution can help you... • Lower operations costs • Automated, accurate billing data acquisition lowers administrative costs and eliminates errors while making the data available to regulators, service providers, and end users. • Improve network reliability • Sophisticated power quality monitoring and reporting provide the information needed to validate compliance, improve system stability, and minimize unplanned downtime. • Streamline business planning • Detailed information on loading, capacity, stress, and more, remove the guesswork so you can more efficiently coordinate demand-side management programs and optimize capacity planning.

  29. Visit us on the web for more information www.schneider-electric.com

More Related