Kanin bir komponetinin alinip, geri kalaninin hastaya veya don?re geri verilmesi islemidir. Sitaferez, kanin h?cresel elemanlarinin ayrilip, geri kalaninin hastaya veya don?re geri verilme islemidir.Plazmaferez, plazmanin ayristirma islemidir.. AFEREZ. . AFEREZ TEKNIKLERI. I. MANUEL Y?NTEMTam kanPlazmaferezII. OTOMATIK Y?NTEMLER1. Sentrifugasyona) Devamli akim b) Intermitan (aralikli akim) 2. Filtrasyon3. Adsorbsiyon.

iden
Download Presentation

DONOR AFEREZI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. DONOR AFEREZI

    2. Kanin bir komponetinin alinip, geri kalaninin hastaya veya donöre geri verilmesi islemidir. Sitaferez, kanin hücresel elemanlarinin ayrilip, geri kalaninin hastaya veya donöre geri verilme islemidir. Plazmaferez, plazmanin ayristirma islemidir.

    3. AFEREZ TEKNIKLERI I. MANUEL YÖNTEM Tam kan Plazmaferez II. OTOMATIK YÖNTEMLER 1. Sentrifugasyon a) Devamli akim b) Intermitan (aralikli akim) 2. Filtrasyon 3. Adsorbsiyon

    4. Aferez prensip Tam Kan (ven)

    5. SANTRIFÜJ TEKNIGI • Santrifüj tekniginde hücreler birbirlerinden özgül agirliklarina göre ayrilirlar:En içten disa dogru: Plazma Trombositler Mononükleer hücreler Granülositler Eritrositler seklinde siralanir Bu yöntem özellikle sitaferez islemleri için uygundur.

    6. Aferez metot Santrifüj yöntemi ile hücreler dansite gradientine göre periferik kandan elde edilir Eritrositler daha yogundur ve dibe gider MNH’ler daha az yogundur ve ortada bulunur (PLT’lerin tam altindadir)

    7. Özgül agirlik Plazma 1.025-1.029 Platelet 1.040 Lenfosit 1.070 MNH-Kök Hücre Granulosit 1.087-1.092 Eritrosit 1.093-1.096

    8. FILTRASYON TEKNIGI Filtrasyon tekniginde delikli bir membrandan geçirilen hücreler ve plazma, membrandaki porlarin çaplarina göre birbirlerinden ayrilirlar. Kan komponentleri birbirlerinden büyüklüklerine (boyutlarina) göre ayrilirlar.

    9. ADSORBSIYON TEKNIGI Daha çok immünoadsorbsiyon islemleri için kullanilan bir uygulamadir. Bioaktif membranlar kullanilarak istenilen elamanlar plazmadan ayrilir.

    10. 1. Sitaferez a) Lökaferez - Periferik kök hücre aferezi - Lenfositaferez - Granülositaferez b) Trombositaferez c) Eritrositaferez d) Fotoferez 2. Plazmaferez Plazma degisimi Plazma filtrasyonu 3. LDL aferezi

    11. I. Terapötik Aferez (hastaya tedavi amaçli) Sitaferez Komponent degisimi Plazma immünomodülatör tedavi II. Donör aferezi (Saglikli vericiden kan komponenti toplanmasi) Plazmaferez Trombositaferez Granülositaferez III. Periferik kök hücre aferezi Otolog Allojeneik

    12. Total kan hacmi hesaplamasi (TKH) Gilcher’in 5’ler kurali

    13. Aferez islemlerinde kullanilan hacim hesaplamalari Total plazma hacmi (TPH)= (1-Htc) X TKH Total eritrosit hacmi (TEH)= Htc X TKH Islem sirasindaki Htc= (TEH-ekstrakorporeal EH) / TKH X100 en az %25 olmalidir.

    14. Kan ve Komponentlerinin Hacimleri (70 kg’lik bir sahista ortalama...) Total kan volümü = 5000 ml Total eritrosit volümü = 2250 ml Total plazma volümü = 2750 ml Total lokosit volümü = 10 ml Total trombosit volümü = 7 ml

    15. Antikoagulasyon ACD (9:1 – 14:1) Bu oran sunlara göre ayarlanir KCFT Platelet sayisi Replasman sivilarina göre Heparin 0.5 – 2.0 u/ml

    16. Kim aferez vericisi olabilir? Yas: 17. – 71. yas (düzenli donor) 17. – 61. yas (ilk kez donor) Vucut agirligi: En az 50 kg Hemoglobin/Htk: =12.5 gr/dL and = 38% Donasyon sikligi: RBC için 56 gün Saglik durumu: Saglikli görünümde ve kendini iyi hissediyor. Tarama: Donasyon zamaninda bir çok sorudan olusan donor degerlendirmesini geçmek zorunda: Eger donor Donor beklemek zorunda Dis muayenesi olmussa: Viziteden 3 gün sonra Nezle, grip veya bogaz agrisi: tam iyilesecek Kulak deldirme/ vücut dövme : 6 ay

    17. Iki islem arasindaki süre 48 saatden az olmamak kaydiyla haftada 2 ve yilda 24’den fazla verici olmamalidirlar. Aspirin kullanan donörlerden 3 gün süre ile trombosit alinmaz. Donör trombosit sayimi en az 150.000/mm3 olmalidir.

    18. Donasyon Sikligi Tam kan veya aferez RBC: 56 gün Çift doz aferez RBC: 112 gün Platelet: 2 gün, haftada 2’yi ve yilda 24 kez geçmemeli Plazma: 28 gün Erkekler yilda 4, kadinlar 3 kez Tam Kan verebilir

    21. Tarama testleri; ABO, Rh tayini, alloantikorlar Transfüzyonla geçen hastaliklarla ilgili testler yapilmalidir HBsAg, anti-HBc-IgM, Anti-HCV, anti-HIV, sifilis. Tek bir verici için testlerin 30 günlük araliklarla tekrarlanmasi önerilmektedir. Gözle görülür eritrosit kontaminasyonu varsa Htc tayini yapilmalidir. Eger 2 ml’den fazla eritrosit içeriyorsa uygunluk testleri yapilmalidir.

    22. Donör Trombosit Aferezi: Nasil, hangi cihazla yapmaliyim? Sayin baskanlar, degerli meslektaslarim, degerli aferez çalisanlari Sizlere donor trombositaferezinden bahsedecegim Good afternoon, ladies and gentlemen. Today, I am gonna talk about donor Trombosit apheresis.Sayin baskanlar, degerli meslektaslarim, degerli aferez çalisanlari Sizlere donor trombositaferezinden bahsedecegim Good afternoon, ladies and gentlemen. Today, I am gonna talk about donor Trombosit apheresis.

    23. Trombositler ne is yapar? Trombositler nasil elde edilir? Trombositlerin asil fonksiyonu : Kanamayi durdurmak ve/veya önlemek Trombosit toplarken iki farkli metot kullanilir: Tek verici trombositleri (SDP= single donor PLT) Otomatik toplama (aferez) yöntemiyle elde edilir Rastgele vericiden alinan trombositler (RDP= random donor PLT) Gönüllü tam kan bagislarindan elde edilir What are Trombosits? How do we collect Trombosits? The primary role of Trombosits is to prevent/control/stop bleeding. There are two different ways to obtain Trombosit concentrate: one is single donor Trombosits (SDPs) which are obtained by automated collection methods. another is random donor Trombosits (RDPs) which are extracted from a community volunteer whole blood donation. What are Trombosits? How do we collect Trombosits? The primary role of Trombosits is to prevent/control/stop bleeding. There are two different ways to obtain Trombosit concentrate: one is single donor Trombosits (SDPs) which are obtained by automated collection methods. another is random donor Trombosits (RDPs) which are extracted from a community volunteer whole blood donation.

    24. Aferez sistemleri ile hazirlanmis trombosit konsantraleri tek bir donörden elde edilir. Buna “single donör trombosit konsantresi” veya “aferez trombosit konsantresi” denir.

    25. AFEREZ TROMBOSITI : Kimlerden Hazirlanir ? Rastgele trombosit aferezi= Toplumdaki vericilerden hazirlanir Aile üyesinden trombosit aferezi= Hastalarin biyolojik aile üyelerinden hazirlanir RDP’ ne yetersiz yanit veren hastalar için kullanilir HLA uyumlu trombosit aferezi= HLA uyumlu vericilerden hazirlanir 4/4 yada ¾ antijen uyumu tercih edilir Sadece trombosit refrakterliginde kullanilir Apheresis Trombosit Preparations: Apheresis Trombosits are obtained from single donors. 1) Random apheresis Trombosits (RAP's) are collected from community donors. 2) Family donor matched Trombosits are collected from a patient's biologic family member. They are used primarily for patients with poor response to RDPs. 3) HLA matched Trombosits are collected from a donor with whom a recipient’s HLA type has been matched. The more desirable matches are 4 in 4 or 3 in 4 antigens. They are considered only for patients who are refractory to RDPs.Apheresis Trombosit Preparations: Apheresis Trombosits are obtained from single donors. 1) Random apheresis Trombosits (RAP's) are collected from community donors. 2) Family donor matched Trombosits are collected from a patient's biologic family member. They are used primarily for patients with poor response to RDPs. 3) HLA matched Trombosits are collected from a donor with whom a recipient’s HLA type has been matched. The more desirable matches are 4 in 4 or 3 in 4 antigens. They are considered only for patients who are refractory to RDPs.

    27. Aferez Trombositi: Niçin tercih edilir? Alloimmunizasyonu önlemek için= Örnek: kök hücre nakli alicilari Trombosit refrakter hastalarin tedavisi için= HLA/Trombosit spesifik antikorlari bulunan hastalar HLA/Trombosit antijen uygun PLT Yönlendirilmis bagis için: Örnek: neonatal trombositopeni Anneden bebege PLT Why are Trombositpheresis Products Requested? They are requested To prevent alloimmunization (e.g., bone marrow transplantation). For refractory patients, HLA/Trombosit antigen matched Trombosit are used for patients with specific HLA/Trombosit antibodies. 3) For directed donations, e.g., mother to baby for neonatal thrombocytopenia (NTP).Why are Trombositpheresis Products Requested? They are requested To prevent alloimmunization (e.g., bone marrow transplantation). For refractory patients, HLA/Trombosit antigen matched Trombosit are used for patients with specific HLA/Trombosit antibodies. 3) For directed donations, e.g., mother to baby for neonatal thrombocytopenia (NTP).

    28. Donör Trombositaferezi: Cihazlar Devamli akim santrifuj Baxter/Fenwal (CS-3000 Plus, Amicus…) Gambro/Cobe (Spectra, Trima …) Fresenius (AS104, AS204, Com.Tec…) Aralikli akim santrifuj Haemonetics (LN-8150 MCS, LN-9000 MCS, MCS Plus, PCS-2…) When we look at the equipment and Technique Current apheresis instruments use continuous flow centrifugation systems like COBEinstruments (Spectra, Trima), Baxter/ Fenwal (CS3000 Plus, Amicus), Fresenius (AS104, AS204, Com.Tec), or intermittent flow centrifugation systems Haemonetics equipments (MCS/MCS Plus, PCS-2) When we look at the equipment and Technique Current apheresis instruments use continuous flow centrifugation systems like COBEinstruments (Spectra, Trima), Baxter/ Fenwal (CS3000 Plus, Amicus), Fresenius (AS104, AS204, Com.Tec), or intermittent flow centrifugation systems Haemonetics equipments (MCS/MCS Plus, PCS-2)

    30. Aferez trombosit avantajlari Ekonomik kan ürünü kullanimi Nispeten daha fazla miktarda seçilmis ürün toplama Daha sik donasyon olasiligi Laboratuarda diger kan ürünleri ayirimina gereksinim olmamasi Çok fazla sayida donore maruziyetinin önlenmesi Hastalik bulasma riskinde azalma HLA alloimmünizasyon riskinde azalma Daha önce alloimmünize olmus hastalarda etkili tedavi Lökosit azaltilmasi Ilave filtrasyon islemine gerek olmamasi Depolama öncesi lökosit azaltilmasi Tekrarlayan FNHTR önlemesi Filtrasyon basarisizligini önlemesi Filtrasyonla olabilen hücre kaybini önlemesi

    31. Aferez trombosit süspansiyonlari 1) HLA immünizasyonu nedeniyle random donör trombosit süspansiyonlarina yanitsiz olan hastalarda HLA veya cross-match uygun aferez trombosit süspansiyonlari önerilmektedir. 2) Yogun trombosit transfüzyonuna gereksinim duyulan hasta gruplarinda Fazla sayida donöre maruziyeti önlemek için Transfüzyon ile bulasan hastaliklardan korumak için yaygin olarak HLA uygun olmayan aferez trombosit süspansiyonlari kullanilmaktadir.

    32. Aferez trombosit ENDIKASYONU 1) HLA immünizasyonu nedeniyle random donör trombosit süspansiyonlarina yanitsiz olan hastalarda HLA veya cross-match uygun aferez trombosit süspansiyonlari önerilmektedir. 2) Yogun trombosit transfüzyonuna gereksinim duyulan hasta gruplarinda Fazla sayida donöre maruziyeti önlemek için Transfüzyon ile bulasan hastaliklardan korumak için yaygin olarak HLA uygun olmayan aferez trombosit süspansiyonlari kullanilmaktadir.

    33. Aferez vs. Random trombosit süspansiyonlari Alloimmünizasyon sikligi Uzun dönem trombosit destegi gereken hastalarda transfüzyon sikligi Etkinlik Bakimindan anlamli farklilik göstermemektedir.

    34. Aferez trombositi: Özellikler If we look at characteristics of Donor Trombositapheresis Product: 1) They are available in one or more different sizes. 2) Each unit must contain at least 3x10e11 Trombosits in 200-700 mL (90%) according to AABB. 3)Leukocyte must be less than <5 x10e6 according to USA standards and <1x10e6 according to european standards. 4) pH must be 6.8-7.4 ( at least more than > 6.2 at 5 days) (90%) 5) They are stored at temperature between +20-24?C for 5 days and agitated continuously in appropriate equipment during storage 6)They are stored for 5 days. However, some studies report that if product culture is negative on days 1-3, shelf-life of products can be extended to 7 days. SDPs must be stored in plastic bags which must be gas permeable to ensure oxygen availability for Trombosits. Trombosit survival time is normal when Trombosits are stored at 22?C or above but is reduced after storage at lower temperatures. The storage duration is primarily determined by relatively high risk of bacterial growth at room temperature. Currently, IN USA, Trombosit storage is limited to 5 days due to the potential bacterial growth over time. Some studies (European) reported that if the culture of Trombosit product is negative on 1-3 days of storage, culture-negative Trombosits’ shelf life can be extended to 7 days. So, the number of outdates is reduced.If we look at characteristics of Donor Trombositapheresis Product: 1) They are available in one or more different sizes. 2) Each unit must contain at least 3x10e11 Trombosits in 200-700 mL (90%) according to AABB. 3)Leukocyte must be less than <5 x10e6 according to USA standards and <1x10e6 according to european standards. 4) pH must be 6.8-7.4 ( at least more than > 6.2 at 5 days) (90%) 5) They are stored at temperature between +20-24?C for 5 days and agitated continuously in appropriate equipment during storage 6)They are stored for 5 days. However, some studies report that if product culture is negative on days 1-3, shelf-life of products can be extended to 7 days. SDPs must be stored in plastic bags which must be gas permeable to ensure oxygen availability for Trombosits. Trombosit survival time is normal when Trombosits are stored at 22?C or above but is reduced after storage at lower temperatures. The storage duration is primarily determined by relatively high risk of bacterial growth at room temperature. Currently, IN USA, Trombosit storage is limited to 5 days due to the potential bacterial growth over time. Some studies (European) reported that if the culture of Trombosit product is negative on 1-3 days of storage, culture-negative Trombosits’ shelf life can be extended to 7 days. So, the number of outdates is reduced.

    35. Ürün pH depolama süresince 6.8 - 7.4 arasinda olmalidir Trombositlerin yeterli miktarda plazma ile süspanse edildigini ve uygun isida saklandigini gösterir pH degeri = 6 (FDA) pH degeri = 6.2 (AABB) pH degeri =6.8 (Avrupa) pH’ i etkileyen en önemli faktör : ürün hacmi ve trombosit sayisidir PLT fazla ve plazma az ise pH ? pH ?= PLT sekil degisikligi ve canliligi ? Donor trombositaferezi ürünü: pH When we look at the pH: During storage product pH must remain between 6.8 - 7.4. Lets look at the pH requirements at the end of the storage period. FDA requires no less than 6.0 AABB requires more than 6.2 Europe requires more than 6.8 As a result, component volume and the number of Trombosits in the component are the most important measures affecting Trombosit product pH. (pH may decrease during storage of Trombosit components with a high Trombosit concentraion pH is an indicator to demonstrate Trombosits are resuspended in adequate amount of plasma and stored at an optimal temperature. pH of Trombosit components decreases during storage owing to cell metabolism. When oxygen availability is limited, glycolysis ensues and lactic acid production increases. Therefore, the increased production of lactic acid in the course of glycolysis result in (lead to=cause) a decrease in pH. Trombosits naturally exist in an environment with a pH value of 7.4. If sufficient oxygen is not available, pH decreases. As the pH decreases to between 6.8 and 6.2, Trombosits gradually lose their discoid appearance and become spherical. This transformation is reversible with no loss of viability, but pH decreases to 6.0 and below an irreversible transformation takes place. The resulting Trombosits are not suitable for transfusion.) When we look at the pH: During storage product pH must remain between 6.8 - 7.4. Lets look at the pH requirements at the end of the storage period. FDA requires no less than 6.0 AABB requires more than 6.2 Europe requires more than 6.8 As a result, component volume and the number of Trombosits in the component are the most important measures affecting Trombosit product pH. (pH may decrease during storage of Trombosit components with a high Trombosit concentraion pH is an indicator to demonstrate Trombosits are resuspended in adequate amount of plasma and stored at an optimal temperature. pH of Trombosit components decreases during storage owing to cell metabolism. When oxygen availability is limited, glycolysis ensues and lactic acid production increases. Therefore, the increased production of lactic acid in the course of glycolysis result in (lead to=cause) a decrease in pH. Trombosits naturally exist in an environment with a pH value of 7.4. If sufficient oxygen is not available, pH decreases. As the pH decreases to between 6.8 and 6.2, Trombosits gradually lose their discoid appearance and become spherical. This transformation is reversible with no loss of viability, but pH decreases to 6.0 and below an irreversible transformation takes place. The resulting Trombosits are not suitable for transfusion.)

    36. Aferez platelet : Bakteriyel Tespit ~1/1000 PLT unit bakteri içerir Yilda ~100 PLT alicisi kontaminasyon nedeniyle ölür Bakteri tespit yöntemleri : Görsel PLT Swirling inspeksiyonu Spesifisite oldukça düsük, sensitivite % 50-75 Mikroskopik inceleme Spesifisite > %99.0, sensitivite % 80-100 pH ve glukoz ölçümü Bakteriyel Kültür Iki ticari sistem var CO2 olusumunu tespit eder (BioMerieux BacT/ALERT) O2 tüketimini tespit eder (Pall BDS) Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).

    37. Aferez platelet : Bakteriyel Tespit 1) Görsel PLT Swirling inspeksiyonu PLT morfolojisi PLT canliligini gösterir Diskoid PLT’ler; viabilitesi daha iyidir Swirling düsük Ph’da bakteriyel metabolizma sonucu azalir PLT’ler 10e7-10e8 CFU/mL bakteri varliginda “swirl” kaybederler. Ancak, 5 günlükten daha fazla PLT’ler “swirl” olmadigi bildirilmektedir. Bu yüzden bakteri tespiti için bu yaklasimin spesifitesi oldukça düsüktür Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).

    38. Aferez platelet : Bakteriyel Tespit Bakteriyel üreme pH düsüsüne neden olur ve bunun sonucu olarak PLT’ler diskoid yapiyi kaybederler; Görsel inspeksiyon (swirling için) bakteriyel kontaminasyonu tespiti için yaklasik %50-75 sensitiviteye sahiptir. Fakat bu yaklasim pH’in en az 6.2 oldugunu gösterir Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).

    39. Aferez platelet : Bakteriyel Tespit 2) Mikroskopik inceleme: Gram boyasi boyanmis örneklerin mikroskopik incelemesi pahali olmayan bir yöntemdir. Nisbeten duyarsiz (özellikle taze komponentte) 1-5 günlük günlük PLT’ler yapilan bir çalismada %80 sensitivite ve %99.96 spesifisite bildirilmistir 4-5 günlük PLT’ler, sensitivite %100, spesifisite ise %99.3 bildirilmistir Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).

    40. Aferez platelet : Bakteriyel Tespit 3) pH ve glukoz ölçümü: Bakteri nedeniyle Ph’da düsüs ve glukoz tüketimi bakteriyel kontaminasyon için kullanilmaktadir. Fakat esik degerleri hakkinda konsensus yoktur Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).

    41. Aferez platelet : Bakteriyel Tespit 4) Bakteriyel Kültür: Bakteriyel çagalmayi tespit etmek için gelistirilmis mevcut 2 ticari sistem vardir Bu sistemlerden biri bakterilerin CO2 olusumuna dayanarak bakteriyel üremeyi gösterir Digeri ise bakterilerin O2 tüketimine dayanarak bakteriyel üremeyi gösterir Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).Bacterial Detection of platelet Products: Approximately 1 in 1,000 platelet units contains bacteria (baktiriya), and nearly 100 platelet recipients die from receiving contaminated units per year in the US. There are several methods to detect bacterial contamination. 1) Visual inspection for PLT Swirling: The morphology of PLTs is predictive of their viability. Discoid PLTs, which have better viability. Swirling is diminished at a lower pH, which can be a consequence of bacterial metabolism. PLTs loose their”swirl” at 10e7-10e8 CFU/mL bacteria levels (Wagner SJ Transfusion 1996). However, up to 20% of 5-day-old PLTs have been reported not to swirl, so the specificity of this approach to detection of bacteria is quite low (Bertolini F Transfusion 1994) Bacterial growth can cause a drop in pH and, as a result, platelets lost of the discoid form; Visual inspection (for maintenance of swirling) has a sensitivity of approximately 50-75% for detecting bacterial contamination. But, this approach does offer the additional benefit to verify that the pH is at least 6.2. (;checking for maintenance of swirling has a sensitivity of approximately 50-75% for detecting bacterial contamination but does offer the additional benefit of verifying that the pH is at least 6.2.) 2) Microscopic examination: Microscopic examination of samples treated with Gram’s stain is an inexpensive method that is relatively insensitive, particularly for fresher components. One study found 80% sensitivity and 99.96% specificity in platelets aged 1-5 days. In 4-5-day –old PLTs, the sensitivity improved to 100%, with a specificity of 99.3% (Yomtovian R Transfusion 1993). 3) Measure pH and glucose : The drop in pH and the consumption of glucose due to bacteria can be used for bacterial contamination . But there is no concensus about their treshold level. 4) Bacterial Culture: There are Two commercial systems to detect bacterial growth; one detects the growth of bacteria by their generation of CO2, and the other detects growth by their consumption of O2 (Brecher ME Transfusion 2002, McDonald CP, Vox sang 2002).

    42. Trombosit ürününü etkileyen faktörler nelerdir? Islem için kullanilan makine Islem öncesi trombosit sayisi Islem öncesi Hb seviyesi Toplam kan hacmi Donör vücut agirligi Donör cinsiyeti Islem süresi Lets look at somethings that affects Trombosit yield. Trombosit yield is affected by ……… Apheresis instruments used, Pre (pri)-donation Trombosit count, Pre-donation Hb level, Total blood volume, Donor weight, Donor gender and Procedure duration. There is wide variation in the number of Trombosits obtained from Trombositapheresis donations. Variability may stem (come=spring=result) from differences in apheresis instruments used, in donor Trombosit counts and in collection parameters (20-24).Lets look at somethings that affects Trombosit yield. Trombosit yield is affected by ……… Apheresis instruments used, Pre (pri)-donation Trombosit count, Pre-donation Hb level, Total blood volume, Donor weight, Donor gender and Procedure duration. There is wide variation in the number of Trombosits obtained from Trombositapheresis donations. Variability may stem (come=spring=result) from differences in apheresis instruments used, in donor Trombosit counts and in collection parameters (20-24).

    43. Donor trombositaferez ürünü belirleyicileri: Oniki Aferez Sistemi On this slide; you can see examples of how different instrument affects Trombosit yield. Depending on the method and instruments used each procedure gave a Trombosit yield from 2.4 to 7.1 x1011 Trombosit.On this slide; you can see examples of how different instrument affects Trombosit yield. Depending on the method and instruments used each procedure gave a Trombosit yield from 2.4 to 7.1 x1011 Trombosit.

    44. Trombosit ürünü: Yedi makinanin karsilastirilmasi The following chart (Figure, table, slide) shows Comparison of seven instruments in terms of Trombosit yield The highest Trombosit yield which was 5.6 x1011 was obtained by Cobe Spectra V4 and the lowest Trombosit yield which was 3.6 x 1011 was obtained by MCS+ (Trombosit yields varied 3.6-5.6 x 10e11).The following chart (Figure, table, slide) shows Comparison of seven instruments in terms of Trombosit yield The highest Trombosit yield which was 5.6 x1011 was obtained by Cobe Spectra V4 and the lowest Trombosit yield which was 3.6 x 1011 was obtained by MCS+ (Trombosit yields varied 3.6-5.6 x 10e11).

    45. When we look at comparison of instruments with respect to Trombosit Yield in Fixed 90 Minute Duration: Amicus and Spectra Turbo were complied best with the target. When we look at comparison of instruments with respect to Trombosit Yield in Fixed 90 Minute Duration: Amicus and Spectra Turbo were complied best with the target.

    46. Aferez trombosit ürünü belirleyicileri: Hb seviyesi Donor Hb’i trombosit ürününün önceden belirlenmesinde önemlidir Ters iliski vardir Düsük hb düzeyinde daha yüksek trombosit ürünü alinir Düsük hb düzeyi yüksek plazma volümüyle iliskilidir Now, Lets look at Hb level and Trombosit yield association: Donor Hb is another variable predictive of Trombosit yield but in inverse fashion: lower Hb corresponds to higher Trombosit yield. Perhaps low Hb concentraion is associated with higher plasma volume processed.Now, Lets look at Hb level and Trombosit yield association: Donor Hb is another variable predictive of Trombosit yield but in inverse fashion: lower Hb corresponds to higher Trombosit yield. Perhaps low Hb concentraion is associated with higher plasma volume processed.

    47. Aferez trombosit ürünü belirleyicileri: Cinsiyet Trombosit ürününde anlamli bir fark yoktur Kadinlarda daha yüksek trombosit ürününe egilim oldugu görülmüstür Yüksek trombosit sayisi temelde ; Uzun islem süresi Ileri derece demir yetersizligi Hormonal etkilesim If we look at Trombosit yield and gender association: There is no significant differences in Trombosit yields between female and male. Some studies revealed that Women tend to have higher Trombosit yield. Reason could be high baseline Trombosit count combined with long procedure time, higher prevalence of iron deficiency among women and Hormonal influence. It is possible that hormonal influence also plays a role because an increase has been observed in Trombosit count in mid-menstrual cycle and decrease at the beginning of the cycle (Rivera SG et al. Arc Med Research 2003;34:120-123 and Lasky LC et al. Transfusion 1981;21:719-22, Kalis et al J Clin Apheresis 1987;3:320-234).If we look at Trombosit yield and gender association: There is no significant differences in Trombosit yields between female and male. Some studies revealed that Women tend to have higher Trombosit yield. Reason could be high baseline Trombosit count combined with long procedure time, higher prevalence of iron deficiency among women and Hormonal influence. It is possible that hormonal influence also plays a role because an increase has been observed in Trombosit count in mid-menstrual cycle and decrease at the beginning of the cycle (Rivera SG et al. Arc Med Research 2003;34:120-123 and Lasky LC et al. Transfusion 1981;21:719-22, Kalis et al J Clin Apheresis 1987;3:320-234).

    48. Aferez trombosit ürünü belirleyicileri: Islem öncesi Trombosit sayisi Elde edilen yüksek ürünün %’si ve trombosit ürününün temel belirleyicisidir Trombosit sayisinin islem öncesi daha fazla olmasi fazla trombosit ürünü eldesine sebep olur Yüksek seviyede trombosit ürünü düsük trombosit sayilarinda da elde edilebilir When we take a look at Predonation Trombosit count and Trombosit Yield association: Predonation Trombosit count is main predictor of Trombosit yield and % of high-yield product. Higher predonation Trombosit count (>220-270-300 x10e3) results in higher Trombosit yield. However, high Trombosit yield can be obtained even with low preprocedure Trombosit count.When we take a look at Predonation Trombosit count and Trombosit Yield association: Predonation Trombosit count is main predictor of Trombosit yield and % of high-yield product. Higher predonation Trombosit count (>220-270-300 x10e3) results in higher Trombosit yield. However, high Trombosit yield can be obtained even with low preprocedure Trombosit count.

    49. Aferez trombosit ürünü belirleyicileri: Islem öncesi Trombosit sayisi: Pre- Trombosit sayisi ile Trombosit ürünü baglantilidir Normal/düsük Trombosit degerli donörlerde islem süresi uzatilarak güvenli kan bagisi saglanabilir Trombosit sayisindaki azalma bagis sikligi ile daha çok iliskilidir You can see in this slide; If you look at the numbers in blue you can see Trombosit yield correlates with pre-donation Trombosit count. If you look at the numbers in red you can see donor with low/normal Trombosit can safely donate satisfactory PCs by extending the procedure time. But, There is a risk of decrease in Trombosit count if a person donate too frequently.You can see in this slide; If you look at the numbers in blue you can see Trombosit yield correlates with pre-donation Trombosit count. If you look at the numbers in red you can see donor with low/normal Trombosit can safely donate satisfactory PCs by extending the procedure time. But, There is a risk of decrease in Trombosit count if a person donate too frequently.

    50. Aferez trombositi: Çift veya daha fazla ünite Trombosit sayisi yüksek olan donörlerde (>250.000/uL) Iki yada üç üniteye karsilik gelen trombosit ürünü elde edilebilir Ürün torbasinda = 6.0 x1011 trombosit olmali (çift unite) Her bir ünite en az > 3 x 1011 trombosit içermeli Islem süresinde hafif uzama Trombosit kaybinda hafif artis Ciddi olmayan donor komplikasyonlarinda hafif artis Lets look at split apheresis Trombosits: Donors with high Trombosit counts are able to donate double or triple doses Trombosit during one donation. Yield in bag must be more than = 6.0 x1011 Trombosits Each unit must contain at least 3 x 1011 Trombosits But, Procedure time is Slightly longer compared to SU.Lets look at split apheresis Trombosits: Donors with high Trombosit counts are able to donate double or triple doses Trombosit during one donation. Yield in bag must be more than = 6.0 x1011 Trombosits Each unit must contain at least 3 x 1011 Trombosits But, Procedure time is Slightly longer compared to SU.

    51. Hangi cihaz ?: Iki ve daha fazla doz When we look at the studies related to split rates: Split rate varies between 5 and 85% depending on instruments used. Split rate is higher in new generation instruments as shown in this slide.When we look at the studies related to split rates: Split rate varies between 5 and 85% depending on instruments used. Split rate is higher in new generation instruments as shown in this slide.

    52. Hangi cihaz ?: Iki ve daha fazla doz When we take a look at the Split Rate in selected Apheresis Instruments: Trima and Amicus have a higher split rate compared to others.When we take a look at the Split Rate in selected Apheresis Instruments: Trima and Amicus have a higher split rate compared to others.

    53. Hangi cihaz ?: Islem süresi Islem süresinin kisa yada uzun olmasi ürün kadar önemlidir Yeni nesil aletlerde islem süresi daha kisadir DN de islem süresi daha kisadir Iki/üç ürün eldesinde islem süresi daha uzun If we look at procedure time: 2) In todays world, “doing more with less time” is important as much as yield when evaluating equipment. 3) new generation instruments have lower processing time compared to others. 4) SN would be expected to have longer PT. 5) Processing time plays a major role in determining CR. Processing time is that blood is being processed (did not include reinfusion or final pass return). If we look at procedure time: 2) In todays world, “doing more with less time” is important as much as yield when evaluating equipment. 3) new generation instruments have lower processing time compared to others. 4) SN would be expected to have longer PT. 5) Processing time plays a major role in determining CR. Processing time is that blood is being processed (did not include reinfusion or final pass return).

    54. Hangi cihaz ?: Islem süresi Aferez Sistemlerinin kiyaslanmasi Procedure time was 64 min for SU and 90 min for DU with Amicus and 77 min for SU and 87 min for DU with Spectra Turbo. So, you can see that we can do more with less time with todays equipments.Procedure time was 64 min for SU and 90 min for DU with Amicus and 77 min for SU and 87 min for DU with Spectra Turbo. So, you can see that we can do more with less time with todays equipments.

    55. Hangi cihaz ?: Toplama yeterliligi (CE) Daha az hacim isleyerek daha fazla ürün elde edilmesini ifade eder Toplanan trombosit ile hesaplanan trombositi karsilastirir: Trombosit ürünü x100/ {(pre+post Trombosit)/2 x (islenen hacim-antikoag hacmi)} Islenen kan volümü CE belirlenmesinde önemli rol oynar Fakat ters iliskilidir CE’nin belirlenmesine katkida bulunan bir diger faktörde üründeki PLT sayisi Yeni cihazlar daha yüksek CE’ne sahiptir CE compares collected amount of Trombosit with calculated. New generation instruments result in higher CE. Blood volume processed plays major role in CE but inverse fashion. For example Trima have to process significantly more whole blood to obtain Trombosit target, which results in a significantly lower CE (Burgstaler et al Transfusion 2004). Design of the collection chambers is another contributing factor in CE: The single stage channel is more efficient in Trombosit collection. This figure compares CE obtained from four Trombositpheresis systems. Amicus was significantly higher CE than all systems with 73%. CE compares collected amount of Trombosit with calculated. New generation instruments result in higher CE. Blood volume processed plays major role in CE but inverse fashion. For example Trima have to process significantly more whole blood to obtain Trombosit target, which results in a significantly lower CE (Burgstaler et al Transfusion 2004). Design of the collection chambers is another contributing factor in CE: The single stage channel is more efficient in Trombosit collection. This figure compares CE obtained from four Trombositpheresis systems. Amicus was significantly higher CE than all systems with 73%.

    56. Hangi cihaz ?: Toplama yeterliligi (CE) Tek vs. çift giris ile toplanmasi Lets look at CE in single vs double needle collections: CEs vary between 42 and 85%. New generation instruments are more efficient than other systems.Lets look at CE in single vs double needle collections: CEs vary between 42 and 85%. New generation instruments are more efficient than other systems.

    57. Hangi cihaz ?: Toplama Orani (CR) Sistemleri kiyaslamada daha pratik bir yöntemdir Es zamanli Trombosit ürünü ve islem süresi ile elde edilir CR= Trombosit ürünü / islem süresi CR’ da islem süresi önemli rol oynar CR is most practical way to compare apheresis systems. CR address Trombosit yield and processing time simultaneously. Processing time plays a major role in determining CR. This table compares CR of 4 systems: Amicus was significantly higher.CR is most practical way to compare apheresis systems. CR address Trombosit yield and processing time simultaneously. Processing time plays a major role in determining CR. This table compares CR of 4 systems: Amicus was significantly higher.

    58. Hangi cihaz ?: Toplama Orani (CR) Sekiz sistemin kiyaslanmasi The following figure shows eight systems comparison in terms of CR: Amicus-SN and DN had a significantly higher CR than all other systems. The following figure shows eight systems comparison in terms of CR: Amicus-SN and DN had a significantly higher CR than all other systems.

    59. Hangi cihaz?: Lokosit azaltilmasi Except for AS104, all other systems met the AABB and European standards.Except for AS104, all other systems met the AABB and European standards.

    60. Aferez ile Lökoredüksiyon Yeni kusak makinalar ile Avrupa / US standartlarinda lokosit azaltilmasi yapilabilmektedir: Laboratuar is yükü azalabilir Ürün kalite ve güvenligi artirabilir Depolama öncesi lökosit sayisi azaltilabilir HLA-alloimmunizasyon riski azalabilir Hastalik bulasma riski azalabilir FNHTR önlenebilir Filtre yetersizligi önlenebilir Filtre ile olusabilecek hücre kaybi önlenebilir Toplamda maliyet avantaji saglayabilir Lets take a look at leukoreduction: A) There is no significant differences between new generation machines. New machines complied with European and US leukoreduction guidelines. C) Leukoreduced apheresis products 1) reduce laboratory workload and 2) increase product quality and safety because of Leukoreduction prior to storage Reduce risk of HLA-alloimmunization (aloimyunizeysin) Reduce risk of disease transmission Prevent FNHTR No filter failure No loss of cells in filter 3) It has also Potential cost advantage. Lets take a look at leukoreduction: A) There is no significant differences between new generation machines. New machines complied with European and US leukoreduction guidelines. C) Leukoreduced apheresis products 1) reduce laboratory workload and 2) increase product quality and safety because of Leukoreduction prior to storage Reduce risk of HLA-alloimmunization (aloimyunizeysin) Reduce risk of disease transmission Prevent FNHTR No filter failure No loss of cells in filter 3) It has also Potential cost advantage.

    61. Hangi cihaz?: Islem sonrasi trombosit sayisi Trombosit sayisi %10-35 oraninda azalmakta Yeni nesil sistemler arasinda anlamli fark yoktur Islem sonrasi trombosit sayisi nadiren 90,000 alti Birkaç günde eski düzeyine ulasmakta Dört günde islem öncesi degere geri yükselmekte Kanama komplikasyonu çok nadir 1) There is no detailed data about effects of different apheresis procedures and split units on donor Trombosit counts. 2) In healthy donors,Trombosit count can drop 10-35% but there is No significant differences between new generation apheresis systems. 3) Rarely it can drop below 90.000 4) recovers in several days without bleeding complications. (Return to baseline was seen in 4 days and a rebound increase above the baseline was seen 8 to 11 days after the procedure (Lasky LC et al. Transfusion 1981;21:247-60)). 1) There is no detailed data about effects of different apheresis procedures and split units on donor Trombosit counts. 2) In healthy donors,Trombosit count can drop 10-35% but there is No significant differences between new generation apheresis systems. 3) Rarely it can drop below 90.000 4) recovers in several days without bleeding complications. (Return to baseline was seen in 4 days and a rebound increase above the baseline was seen 8 to 11 days after the procedure (Lasky LC et al. Transfusion 1981;21:247-60)).

    64. Hangi cihaz? Amicus vs Com.Tec Her iki cihaz ile toplanan hedef trombosit yeterli idi Her iki cihaz ile rehberlere uygun lökoreduksiyon yapilabildi Amicus’un avantaji, daha hizli hedef trombosit ürünü saglanmasi idi

    65. Donör Aferezi: Komplikasyonlar Nisbeten sik Sitrat toksitesi Akim hizinin ayarlanmasi yada kalsiyum uygulamasi ile kontrol edilebilir Islem öncesi rutin kalsiyum uygulamasi önerilmez Hematom yada damar yolu komplikasyonlari Nadir Allerji (Sitrat, set vs) Sellülit Tromboz Volüm durumunda degisiklik Lets take a look at complications: The most common adverse effects are related to citrate useed during the procedures. Fortunately, most citrate related symptoms can be controlled easily by adjusting the machine flow rates or administration of calcium. Authors do not recommend routine administration of oral calcium before apheresis Some authors recommend that donors with a prior history of significant citrate-related symptoms or with high risk of citrate effects (female donors receiving high citrate infusion rates) be given oral calcium 2gr, 30 min before apheresis (Bolon et al 2003) (NIH)Lets take a look at complications: The most common adverse effects are related to citrate useed during the procedures. Fortunately, most citrate related symptoms can be controlled easily by adjusting the machine flow rates or administration of calcium. Authors do not recommend routine administration of oral calcium before apheresis Some authors recommend that donors with a prior history of significant citrate-related symptoms or with high risk of citrate effects (female donors receiving high citrate infusion rates) be given oral calcium 2gr, 30 min before apheresis (Bolon et al 2003) (NIH)

    66. Donöre uzun dönem etkileri Hb, Trombosit ve WBC sayisinda anlamli degisiklik izlenmemekte Mutlak lenfosit sayisi azalabilir Immundisfonksiyona yol açtigi gösterilememis Demir eksikligi da az siklikla görülebilir Trombositaferez tekrarlamak güvenlidir Uzun dönemde önemli olmayan minimal degisiklik olabilir When we look at Long Term Effects of Trombositpheresis on Donors: There is no significant changes in Hb level, Trombosit count or WBC count Absolute lymphocyte counts can be low in, but there is no evidence of immune dysfunction. Iron deficiency is less frequent 4) Repeated Trombositpheresis is safe, with minimal change of long-term effects.When we look at Long Term Effects of Trombositpheresis on Donors: There is no significant changes in Hb level, Trombosit count or WBC count Absolute lymphocyte counts can be low in, but there is no evidence of immune dysfunction. Iron deficiency is less frequent 4) Repeated Trombositpheresis is safe, with minimal change of long-term effects.

    67. Trombositaferez: Ekonomik Uygulanabilirligi RDP’ ile maliyet olarak karsilastirilabilir: Gerekçesi; Yüksek tekrarlama orani Donör maruziyetinin azaltilmasi= Enfeksiyon riskinin azaltilmasi Lökoreduksiyon için ilave manuplasyonlara gerek olmamasi sayilabilir If we look at Economic Feasibility of SDPs: Although costs for SDP are still significantly higher than for RDPs, additional costs of SDPs may be justified by the high split rates obtained and the reduction in risk of infection due to Reduction of donor exposure 3) leukoreduced Trombosits units obtained (Do not require filtration and this contributes to reduced costs and laboratory workload). If we look at Economic Feasibility of SDPs: Although costs for SDP are still significantly higher than for RDPs, additional costs of SDPs may be justified by the high split rates obtained and the reduction in risk of infection due to Reduction of donor exposure 3) leukoreduced Trombosits units obtained (Do not require filtration and this contributes to reduced costs and laboratory workload).

    68. Sonuç Yeni nesil cihazlar yüksek performansa sahip: Trombosit ürünü, toplama kabiliyeti, toplama hizi, ayirma hizi, islem süresi ve donör rahatligi Avrupa/US kilavuzlarina uygun lökosit azaltilmasi Yüksek ayirma hizi, enfeksiyon riskinin azaltilmasi, lökoredüksiyon, maliyeti önemli ölçüde azaltabilir Trombositferez islemi güvenli Uzun dönem etkilerde minimal degisiklik mevcuttur As a conclusion: Newer machines have the best overall performance: in terms of Trombosit yield, collection efficiency, collection rate, split rate, procedure time and donor comfort They Comply with European / US leukoreduction guidelines Significantly higher costs compared to RDPs may be justified by High split rates, reduced risk of infection, Leukoreduction Repeated Trombositpheresis is safe – with minimal change in long-term effects Thank you very much for your attentionAs a conclusion: Newer machines have the best overall performance: in terms of Trombosit yield, collection efficiency, collection rate, split rate, procedure time and donor comfort They Comply with European / US leukoreduction guidelines Significantly higher costs compared to RDPs may be justified by High split rates, reduced risk of infection, Leukoreduction Repeated Trombositpheresis is safe – with minimal change in long-term effects Thank you very much for your attention

    70. Eritrosit aferezi

    71. Eritrosit aferezi Aferez ile 2 eritrosit süspansyonuna esit (2-RBC ) eritrosit toplanmasi 1997’den beri gerçeklestirilmektedir Islemin güvenli olduguna dair çok sayida literatür bulunmaktadir. Islem süresi ortalama 30 dakikadir (donör htc ve toplama hizina bagli) Islem hem otolog hem allojenik amaçli gerçeklestirilebilmekle beraber çogu allojenik amaçli yapilmaktadir. Bu islemlerin sayisi her yil % 40 oraninda artmaktadir.

    72. Eritrosit aferezi

    73. Çogu kan toplayicinin hedef kitlesi B, O ve Rh negatiflerdir. Post donasyon sonrasi süre 16 haftadir. 16 haftalik post donasyon süresi sonrasi bir yil içinde iki eritrosit süspansiyonu donasyonu kan toplayici veya donörler tarafindan kolayca yönetilebilir bir durumdur. Amerikali donör için yillik ortalama eritrosit donasyonu sayisi 1.4 dir. Eritrosit aferezi

    74. Bazi uzmanlar eritrosit donörlerinin % 10’na 2-RBCA islemi yapilirsa eritrosit ihtiyacinin giderilecegini iddia etmektedirler. Aferez kan toplama için yüksek okul ögrencilerini hedef olarak görmektedirler. Genç nüfusun bu otomatik teknolojiye ilgi duymasi Islemde artmis donör güvenligi. Eritrosit aferezi

    75. Yüksek okul ögrencilerinin %16 da vazovagal reaksiyonlar izlenmektedir. Agirlik ve ilk defa kan donörü olmak önemli risk faktörleridir. Aferez orta ve agir vazo vagal reaksiyon sikligini azaltir. % 2-5 sikliginda vazovagal reaksiyon, %0.08-0.34 sikliginda senkop görülmektedir. Izotonik solüsyonlarin kullanilmasi veya Uzun aferez islemi sirasinda saglanan sivi dengesi nedeni ile olabilir. Eritrosit toplanmasi islem üzerinde daha fazla kontrol imkani verir. Wiltbank KT et al. Transfusion 2002; 42: 678. Popovsky MA. Blood Therapy Med 2002; 2: 1-3 Eritrosit aferezi

    76. Wiltbank ve arkadaslarinin yaptigi bir çalismada aferez donörlerinde (2-RBCA veya RBC-plazma) manuel islemlerde orta dereceli reaksiyonlarin görülme sikligi 10.000 hastada %14.5, aferez islemlerinde %6.2 dir. Eritrosit aferezi

    77. Iki eritrosit süspansiyonun bir donörden toplanmasi ile (veya diger komponent kombinasyonlari) kan merkezleri donör öyküsü kan toplanmasi enfeksiyon hastaliklari testleri ve komponent hazirlanmasi ilgili yanlisliklarin olusma sansini azaltir. Daha az donör maruziyeti oldugu güvenli bir ürün saglar. Her iki yari ürün ayni kisiye transfüzyon yapilabilir. Manuel toplanan tam kanin eritrosit hacimleri degiskenlik gösterir. Bu donörlerin hematokriti ve hacimleri arasindaki farktan dolayidir. Eritrosit kitleleri arasindaki fark % 40 a kadar çikabilir. Popovsky MA. Blood Therapy Med 2002; 2: 1-3 Eritrosit aferezi

    78. MULTIKOMPONENT AFEREZI

    79. ABD de 1999 ve 2001 yillari arasinda eritrosit, trombosit ve plazma ihtiyaci sirasi ile % 12, %15 ve % 18 oraninda artmistir. Kan yoklugu nedeni ile cerrahi operasyonlarin % 13’ü ertelenmistir Multikomponent toplanmasi (MCC) aktive edilmeden bu sartlar zor kompanse edilebilir

    80. Donörlerin % 95 nin MCC programina geçirilebilecegi gösterilmistir. %15-20 MCC programina geçmeyi rededetmektedir. Berman KE. Transfusion Med Rev.2004;18:1-10

    81. Multipl aferez ürünlerinin toplanmasi, eritrosit de dahil giderek artmakta ve total aferezde zorunlu hale gelmektedir. Bu yolla donör kullanimi gelistirilmekte Kan transfüzyon maliyeti düsmektedir. Ayni anda trombosit ve plazma veya eritrosit süspansiyonu toplanmasi ürün kalitesi ve WBC kontaminasyonu yönünden trombosit ürününü etkilememektedir.

    82. Aferez öncesi trombosit sayisi 200-300x10³µL oldugunda; Islem süresi 60-90 dakika Toplanan trombosit miktari: 3-5x10¹¹ WBC kontaminasyonu: 0.1-0.5X106(% 95 MNH95) Council of Europe RecomendationN.(95)15 on the preparation use and quality assurance of blood components. 10th edition. 2003 version

    83. Plazma trombositlerle birlikte, 250 ml veya 600 ml (PTA, DPTA) kullanilan cell separatöre bagli olarak toplanabilir

    85. Double trombosit genellikle trombosit sayisi 290-300x10³µL, 70 kg. Trombositlerle birlikte eritrosit toplanabilir (ETA, Eritro-trombosit aferezi) Veya çift eritrosit ve trombosit toplanabilir (DETA, double eritro-trombosit aferezi)

    87. Her cihaz özelliklerine bagli olarak minumum 1Ü (en az 50 gr Hb) Veya 2Ü eritrosit ile birlikte trombosit toplayabilir (RBC, en az 110 gr Hb) Bu sekilde toplanan ürün(RBC) immünolojik yükü ve virolojik riski azaltacagi için bir alici için idealdir

    88. Hiçbir cihaz santrifugasyon ile lökositi azaltilmis eritrosit toplayamaz. Ancak cihazin üzerine takilan set yardimi ile lökosit arindirma islemi yapilabilinmektedir. Filtrasyon islemi immünmodülasyon ve non-hemolitik transfüzyon reaksiyonunu azaltmak için gerekebilir.

    89. MCA donasyon algoritmasi (San Martino Hastanesi Aferez Ünitesi)

    90. Manuel ve MCA yöntemi ile toplanan eritrositlerdeki degisiklikler

    91. O. Gün MRBC ARBC Glukoz yüksek düsük ATP yüksek düsük Serbest hb fark yok fark yok Hemoliz fark yok fark yok K+ salinimi düsük yüksek PH yüksek düsük 49. Gün Glukoz kullanimi düsük yüksek Laktat olusumu esit veya yüksek esit ATP düzeyi baslangiç %70 %43-60 Hemoliz hizi fark yok (<%0.6) fark yok (<%0.6) Serbest hb < 200 mgr/dL <200 mgr/dL Supernatan K+ düsük yüksek PH düsük (0.65-0.70/U) düsük (0.65-0.70 /U) Susanne M et al. 2007;47:687-696 Manuel ve MCA yöntemi ile toplanan eritrositlerdeki degisiklikler

    94. MCA ekonomik avantajlar

    96. MCA de donör güvenligi MCA, konvansiyonel donasyon kadar güvenlidir. Tibbi personel hastaya yakin Volüm replasmani yapilmasi kalsiyum ilavesi Motive edilmis donörler

    97. Hasta için avantajlar Viral maruziyetin azalmasi Kuru trombosit eldesi ile TRALI sikliginda azalma Hemolitik reaksiyon riskinde azalma Trombosit immün refrakterliginde gecikme Eritrosit immunizasyonunda gecikme

    98. MCA- Sonuç MCA, özellikle 2-RBCA önümüzdeki yillarda artacaktir. Donör teminine ait yaklasimlar kan temininde arz ve talep arasindaki büyüyen açigi karsilayamamaktadir. Donor maruziyetini azalttigi ve standart doz eritrosit süspansiyonu sundugu için; 2-RBCA transfüzyon klinisyenleri bu tür ürünlerin kullaniminda israr etmektedirler. Hemoglobin içeriginin ölçülerek uygun transfüzyon miktarinin hesaplandigi ve eritrosit süspansiyonu transfüzyonunun %30 azaldiginin gösterildigi çalisma gelecekte yeni yaklasimlara yol açabilir Arslan O et al. Transfusion 2004;44:485–488.

    99. Sitrat toksisitesi Islem yavaslatilarak veya Ca+2 verilerek asilabilir Hemoliz Hava embolisi Hipovolemi Platelet sayilarinda kalici düsüklük Donasyon sikligi ayarlanmalidir Hemostatik bozukluk