1 / 23

Technical update

Technical update. Service meeting Codroipo 13/14-06-05. IDROWALL Range. NEW. Wall fan-coil. Range from 1,3 up to 2,5 kW. Index. COMPARISON OLD NEW REATURES ACCESSORIES ELECTRONIC FUNCTIONS MASTER SLAVE. IDROWALL. IDROWALL. 4 models. 3 models.

jaguar
Download Presentation

Technical update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Technical update Service meeting Codroipo 13/14-06-05

  2. IDROWALL Range NEW Wall fan-coil Range from 1,3 up to 2,5 kW

  3. Index • COMPARISON OLD NEW • REATURES • ACCESSORIES • ELECTRONIC • FUNCTIONS • MASTER SLAVE

  4. IDROWALL IDROWALL 4 models 3 models Cooling capacity 1,02 ÷ 3,4 Cooling capacity 1,32 ÷ 2,48 Features External valve in the frame Work with water temperature till 55°C Features 2 Versions: - With inside valve - Without valve Work with water temperature till 70°C Microtech electrical board Carel electrical board master-slave function Dimensions Models 10-20-30: 800x280x200 mm Models 40: 950x280x155 mm Dimensions Models 22-33-44: 950x280x155 mm Accessories Remote control Wall control panel Wall recessed box with valve Wall recessed box with electronic 3 way valve Accessories New infrared remote control New wall control panel New wall recessed box Comparison OLD - NEW NEW OLD

  5. Comparison OLD-NEW • Cooling power Acqua: 7/12°C Aria: 27°C B.S. 19°C B.U. • 3 modelli

  6. Comparison OLD-NEW • Thermal power Acqua: 70/60°C Aria: 20°C B.S. Acqua: 45°C / portata come in raffredd. Aria: 20°C B.S. • 3 modelli

  7. Features – application field t °C = inlet water temperature U.R.% = ambient air relative humidity

  8. features – Version with electrovalve. Air vent valve easely accessible Water discharge valve on the coil

  9. NEW Supplyed loose accessories KPCM – new control board with 11 keys

  10. Accessori forniti separatamente KTCM – LCD infra-red remote control NEW

  11. Supplyed loose accessories • KVDF – wall recessed box for the predisposition of the system side piping before the installation,completed of : • Quick connection with ball valve • Flexible connection piping NEW

  12. Electrical board Lay-Out Valve Fan Serial Flap ST1 ST2 Hall Riceiver

  13. Clamps • Idrowall 22 - 44 • SCR = remote On-Off • KPCM = control board • C = aux contact • EIR = remote summer winter • SIC = remote safety • ECO = energy save • Serial connection • Available soon KPCM Idrowall 10 - 40 SCR = remote On-Off KPAN = control board CKRP = aux contact RS 485 = serial connection VI = on – off valve

  14. Dip-Swiches configurayion

  15. NEW OLD Allarmi

  16. Funzioni • Regulation functions : • Full auto • Cool • Heat • Fan • Dry • confort functions: • Orienting/Swing (selection of the deflector position: swingin or fixed ) • Auto Fan / Fan speed (manual or authomatic ventilation) • Sleep (night climatization function) • Too cool (summer block for temperature over 18°C ) • Hot start (winter consent of minimum temperature [32; 36; 40 °C] )

  17. Functions • Advanced functions: • Security control(il possible to subordinate the unit running to a remote control, clean contact. For example is possible to interrupt the running if a window is open with a control positioned in the window itself .) • Economy (‘’save energy’’ function. You can enable it from a DIP switch positioned in the electrical board and activate it with a clean contact in alternative of the function ‘security control’) • On/Off remote control(allows the switching on and off of the unit from a remote switch ,clean contact) • Lock function(conditioning bounded for Hotel rooms) [Full auto; Free vent ; auto mode if not SEI] New New New

  18. Funzioni • Le funzioni avanzate: • Continuous ventilation(when the temperature set-point is reached the ventilation is forced to the lower speed) • Timer(allows 1 daily ciclic programmed switching on/off of the unit) • Probe in / Probe out(the ambient tmeperature can be felt by an inside probe (PROBE IN) or by a probe fixed in the unit (PROBE OUT)). • Memory(after a black-out ,the unit will restart in the way that had immediatly before the supply black out). New

  19. FUNZIONI • Periodical ventilation • activ in cool/dry heat • Not active with probe in • super-periodic ventilation at the start of the full-auto function (shorted after the remotation of the inside probe) • Is possible to read and change the parameters through the KPCM • The infrared remote control has to be configured at the first start up New New New New

  20. Configurazione telecomando • Page 9 of the user manual

  21. CONTROLLO A FILO o TELECOMANDO New Till a max N° of 5 slave units Master - SlaveFunction MASTER SLAVE SLAVE SLAVE MAIN FEATURES • “broadcasting”logic:the units are all working in the same zone making exactly the same functions set in the MASTER • In the sign of continuity:easy electric connection between the control board of the single unit • More flexible:new for IDROWALL

  22. Master-Slave Function

  23. Master-Slave function • Master-Slave net with remote control: connect the electrical heater (rpower 1,2 Kohm 0,5W) • The electronic board self-configures itself as master for the presence of the panel or of the electrical heater in the first unit Con pannellino si può scegliere Probe in/out • Diagnostic on Slave only with the LED • Inlets Slave ECO, EIR, Lock Func., are disactivated • SCR Master: blocks all the chain • SCR Slave: Blocks only the specific unit • SIC:Blocks only the specific unit New New