1 / 31

Outline of Presentation : Motivation: Acoustic Doppler Velocimeter (ADV) Field O bservations

Dual Use of a Sediment Mixing Tank for Calibrating Acoustic Backscatter and Direct Doppler Measurement of Settling Velocity (and Related Field Motivation and Observations) Grace Cartwright, Carl Friedrichs , and Paul Panetta. Outline of Presentation :

kyna
Download Presentation

Outline of Presentation : Motivation: Acoustic Doppler Velocimeter (ADV) Field O bservations

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dual Use of a Sediment Mixing Tank for Calibrating Acoustic Backscatter and Direct Doppler Measurement of Settling Velocity (and Related Field Motivation and Observations)Grace Cartwright, Carl Friedrichs, and Paul Panetta • Outline of Presentation: • Motivation: Acoustic Doppler Velocimeter (ADV) Field Observations • Sediment Mixing Tank: Acoustic Backscatter Calibrations • Sediment Mixing Tank: Doppler Settling Measurements • Independent field-based test of ADV-measured settling velocity

  2. Motivation: Determine fundamental controls on sediment settling velocity and bed erodibility in muddy estuaries (X-rays courtesy of L. Schaffner) Study site: York River Estuary, VA Physical-biological gradient found along the York estuary : -- In the middle to upper York River estuary, macrobenthos are seasonally overwhelmed by the floc-rich estuarine turbidity maximum, and sediment layering is often preserved. (e.g., Clay Bank – “Intermediate Site”) -- In the lower York and neighboring Chesapeake Bay, layering is generally destroyed by bioturbation, and abundant macrobenthos pelletize the mud as they feed (e.g., Gloucester Point – “Biological Site”) -- Acoustic Doppler Velocimeter (ADV) tripods provide long-term observations within a strong physical-biological gradient.

  3. Observations provided by a Sontek 5 MHz Acoustic Doppler Velocimeter (ADV) Sensing volume ~ 35 cmab ADV after retrieval ADV at deployment (Photos by C. Cartwright) • -- ADVs often provide quality long-term data sets despite extensive biofouling. • -- ADVs can provide continual long-term estimates of: • 3-D velocity (u,v,w) in ~ 1 cm3 sampling volume including ~ Hz turbulent fluctuations (u’,v’,w’) • Suspended mass concentration (c) from acoustic backscatter including turbulent fluctuations (c’) • Turbulent Reynolds Shear Stress, τ = ρ*<u’w’> • Sediment Settling Velocity, ws = <w’c’>/c • Elevation of seabed relative to tripod

  4. Significant scatter in suspended solids vs. acoustic backscatter relationship because of variations in suspended particle size, particle density, and response of individual ADVs • Concentration • Calibration Curves • In-situ pump samples • analyzed for total • suspended solids • Concentrations • used to calibrate • acoustic backscatter • from deployed tripods • All observations • utilize Sontek • 5 MHz ADV • “Ocean” Model (Cartwright et al., 2009)

  5. Lower Concentration Period at Biological(Gloucester Point) site (ADV height ~ 35 cm) Current (cm/sec) ~ 40 cm/s ~ 50 mg/l TSS (mg/liter) ~ 4 cm change Bed elev (cm) Days since December 4, 2006 (Cartwright et al. 2009)

  6. Assume: (Fugate & Friedrichs, 2003) Upwards turbulent sediment flux Downwards gravitational settling = <w'C'> = ws <C> w' = vertical turbulent velocity, C' = turbulent concentration fluctuation < > = burst average, ws = sediment settling velocity, <C> = burst-average TSS Biological site (GP) ADV Data: <w'C'> (mm/s)(mg/liter) Slope = ws = <w’C’>/<C> = 1.5 mm/s <C> (mg/liter) -- Insensitive to ADV calibration for C , 50% change in calibration = 10% change in ws. (Cartwright et al. 2009)

  7. Higher Concentration Period at Intermediate(Clay Bank) site (ADV height ~ 35 cm) ~ 40 cm/s Current (cm/sec) ~ 100 mg/l TSS (mg/liter) ~ 20 cm change Bed elev (cm) Days since February 27, 2007 (Cartwright et al. 2009)

  8. Higher Concentration Period at Intermediate(Clay Bank) site (ADV height ~ 35 cm) ws = 0.77 mm/s ws = 0.55 mm/s ws = 0.20 mm/s Current (cm/sec) Current (cm/sec) <w'C'> vs. <C> <w'C'> vs. <C> <w'C'> vs. <C> TSS (mg/liter) ws = 0.80 mm/s Bed elev (cm) <w’C’> vs. <C> Days since February 27, 2007 (Cartwright et al. 2009)

  9. Seasonal Variability in sediment settling velocity (ws ) and erodibility (e) is observed at the Intermediate Site. 3- day Mean Wsfrom fits to <w’C'> = ws<C> using ADVs 2 1.5 Biological site Ws ~ 1.5 mm/s Ws(mm/s) 1.0 Intermediate site Ws varies from ~ 0.5 mm/s to ~ 1 mm/s 0.5 0 3-day mean of erodibility (e) using ADVs and Gust erosion chambers 6 5 4 Intermediate site ε varies from ~ 3 kg/m2/Pa (Regime 1) to ~ 1 kg/m2/Pa (Regime 2) 3 ε (kg/m2/Pa) 2 Biological site Generally < 1 kg/m2/Pa 1 Cartwright et al., 2009

  10. Seasonal Variability in sediment settling velocity (ws ) and erodibility (e) is observed at the Intermediate Site. 3- day Mean Wsfrom fits to <w’C'> = ws<C> using ADVs 2 1.5 Biological site Ws ~ 1.5 mm/s Ws(mm/s) 1.0 Intermediate site Ws varies from ~ 0.5 mm/s to ~ 1 mm/s 0.5 Questions: -- Are these ADV-based estimates of sediment concentration and settling velocity accurate and reliable? -- Can controlled lab experiments provide insight? 0 3-day mean of erodibility (e) using ADVs and Gust erosion chambers 6 5 4 Intermediate site ε varies from ~ 3 kg/m2/Pa (Regime 1) to ~ 1 kg/m2/Pa (Regime 2) 3 ε (kg/m2/Pa) 2 Biological site Generally < 1 kg/m2/Pa 1 Cartwright et al., 2009

  11. Dual Use of a Sediment Mixing Tank for Calibrating Acoustic Backscatter and Direct Doppler Measurement of Settling Velocity (and Related Field Motivation and Observations)Grace Cartwright, Carl Friedrichs, and Paul Panetta • Outline of Presentation: • Motivation: Acoustic Doppler Velocimeter (ADV) Field Observations • Sediment Mixing Tank: Acoustic Backscatter Calibrations • Sediment Mixing Tank: Doppler Settling Measurements • Independent field-based test of ADV-measured settling velocity

  12. (a) VIMS Sediment Mixing Tank, with suspended sampling tubes highlighted, (b) example placement of ADV in chamber, with pump circulation outlets highlighted (Photos by C. Cartwright) Acrylic portion of tank is 32 cm x 32 cm x 1.5 m, with bottom 0.5 m tapering in toward the 44 liter/minute pump inlet. Flow is returned 25 cm below the top of the tank through 4 circulation outlets. Sediment concentration is sampled at 1 m/s through sampling tubes.

  13. Lab calibration with quartz sand: -- Commercially available, predominantly quartz sand was divided into size classes using sieves with mesh diameters of 63, 75, 90, 106, 125, and 150 microns. Example of 63 micron component Example of 125 micron component (Photos by C. Cartwright)

  14. Sediment Mixing Tank: Acoustic Backscatter Calibrations (With ADV mounted mid-chamber) • Quartz Sand Only calibrations (For each phi size) • A successive series of sand was added to the chamber • Acoustic backscatter collected for 10 minutes (10Hz) and averaged. • For each concentration a water sample was pulled from mid-chamber • Samples were dried and weighed for suspended mass concentration. • Mixed Sediment and Mud Only calibrations (For three sites) • (This section of experiment part of Newbill, 2010) • Analysis methodology similar to Sand Only calibrations • Did calibrations with natural muddy sediment collected from 3 sites • Claybank (CB) Channel (~1 % sand) • Claybank (CB) Shoal (~20 % sand) • Ferry Point ( FP) Shoal (~10% sand) • Repeated calibrations with Mud Only portions <63 microns • Claybank (CB) Shoal • Ferry Point ( FP) Shoal Sampling Tubes (Photo by C. Cartwright)

  15. Sediment Mixing Tank: Acoustic Backscatter Calibrations (With ADV mounted mid-chamber) • Quartz Sand Only calibrations (For each phi size) • A successive series of sand was added to the chamber • Acoustic backscatter collected for 10 minutes (10Hz) and averaged. • For each concentration a water sample was pulled from mid-chamber • Samples were dried and weighed for suspended mass concentration. • Mixed Sediment and Mud Only calibrations (For three sites) • (This section of experiment also part of Newbill, 2010) • Analysis methodology similar to Sand Only calibrations • Did calibrations with natural muddy sediment collected from 3 sites • Claybank (CB) Channel (~1 % sand) • Claybank (CB) Shoal (~20 % sand) • Ferry Point ( FP) Shoal (~10% sand) • Repeated calibrations with Mud Only portions <63 microns • Claybank (CB) Shoal • Ferry Point ( FP) Shoal Sampling Tubes (Photo by C. Cartwright)

  16. Mixed Mud & Sand Sediment Mass Concentration (log10 mg/liter) Mud only Solid Lines Sand Only ADV Backscatter (counts) -- ADV backscatter systematically increases with concentration for any one sediment type. -- For quartz sand, ADV backscatter systematically increases with sand grain diameter. -- Natural mud responds less strongly than sand, but response is site specific. -- Mud + Sand is also site specific and doesn’t respond as a sum or average of the two.

  17. Dual Use of a Sediment Mixing Tank for Calibrating Acoustic Backscatter and Direct Doppler Measurement of Settling Velocity (and Related Field Motivation and Observations)Grace Cartwright, Carl Friedrichs, and Paul Panetta • Outline of Presentation: • Motivation: Acoustic Doppler Velocimeter (ADV) Field Observations • Sediment Mixing Tank: Acoustic Backscatter Calibrations • Sediment Mixing Tank: Doppler Settling Measurements • Independent field-based test of ADV-measured settling velocity

  18. Sediment Mixing Tank: Doppler Settling Measurements -- For each sand size, a grid of vertical velocity ADV measurements were collected with 10 min at each point cm/s (Photo by C. Cartwright) ADV mounted above Circulation outlets 2-D map of vertical Doppler velocity (+ = upward, - = downward) (Example for 125 micron case) -- Vertical velocity measurements are total velocity of sand + water, i.e., ws + <w>. -- Horizontally-integrated flow associated with water along, <w>, must add up to zero. -- So the spatially averaged sum of ws+ <w> must be the sediment settling velocity, ws. -- However, the spatial coverage of the tank by the ADV is incomplete.

  19. Map of vertical Doppler velocity (+ = upward, - = downward) (Example for 125 micron case) a) Measured flow cm/s -- Spatially averaged sum of ws+ <w> must be the sediment settling velocity, ws. -- However, the spatial coverage of the tank by the ADV is incomplete. -- Radially symmetry of tank can be used to extrapolate and interpolate flow before averaging to solve for settling velocity, ws. c) Interpolated flow b) Measured flow

  20. What independent “true” sand settling velocity can we compare Doppler measurements to? Answer: Rapid Sediment Analyzer (RSA) Balance connected to computer Sediment drop and start button Thermometer to measure water temp. Settling tube filled with water Computer records weight and settling time Metal plate connected to balance (~150 cm from sediment top) (Photo by C. Cartwright)

  21. Rapid Sediment Analyzer (RSA) Example output from 106 micron sieve Mean Ws = 1.310 ±0.063 cm/sec (Photo by C. Cartwright)

  22. Sediment Mixing Tank: Doppler Settling Measurements RSA Ws and Individual Flow Fit Ws comparison RSA Ws and Global Flow Fit Ws comparison Ws from individual Doppler velocity fits (cm/s) Ws from global Doppler velocity fits (cm/s) Ws from Rapid Sand Analyzer (cm/s) Ws from Rapid Sand Analyzer (cm/s) Global Flow Fit Use result from average of all best-fit slopes of velocity vs. radial distance for all sizes, since slope (i.e., spatial distribution of flow) is entirely due to water, not sand. Individual Flow Fit a) Regression of distance from center vs. <w> b) Circular fit of regression

  23. Dual Use of a Sediment Mixing Tank for Calibrating Acoustic Backscatter and Direct Doppler Measurement of Settling Velocity (and Related Field Motivation and Observations)Grace Cartwright, Carl Friedrichs, and Paul Panetta • Outline of Presentation: • Motivation: Acoustic Doppler Velocimeter (ADV) Field Observations • Sediment Mixing Tank: Acoustic Backscatter Calibrations • Sediment Mixing Tank: Doppler Settling Measurements • Independent field-based test of ADV-measured settling velocity

  24. This field method was the motivation – But it couldn’t be used in the mixing tank! (The spatial variation in concentration couldn’t be resolved in the tank) Assume: (Fugate & Friedrichs, 2003) Upwards turbulent sediment flux Downwards gravitational settling = <w'C'> = ws <C> w' = vertical turbulent velocity, C' = turbulent concentration fluctuation < > = burst average, ws = sediment settling velocity, <C> = burst-average TSS Biological site (GP) ADV Data: <w'C'> (mm/s)(mg/liter) Slope = ws = <w’C’>/<C> = 1.5 mm/s <C> (mg/liter)

  25. This field method was the motivation – But it couldn’t be used in the mixing tank! (The spatial variation in concentration couldn’t be resolved in the tank) Assume: (Fugate & Friedrichs, 2003) Upwards turbulent sediment flux Downwards gravitational settling = <w'C'> = ws <C> w' = vertical turbulent velocity, C' = turbulent concentration fluctuation < > = burst average, ws = sediment settling velocity, <C> = burst-average TSS Question: -- It there a reliable, independent measure of ws we can use in the field? Biological site (GP) ADV Data: <w'C'> (mm/s)(mg/liter) Slope = ws = <w’C’>/<C> = 1.5 mm/s <C> (mg/liter)

  26. Period of strongest flow Comparison of ADV measurements to camera measurements of from York River estuary from October 6th 2012 (just last week): Promising!

  27. Dual Use of a Sediment Mixing Tank for Calibrating Acoustic Backscatter and Direct Doppler Measurement of Settling Velocity (and Related Field Motivation and Observations)Grace Cartwright, Carl Friedrichs, and Paul Panetta • Outline of Presentation: • Motivation: Acoustic Doppler Velocimeter (ADV) Field Observations • Sediment Mixing Tank: Acoustic Backscatter Calibrations • Sediment Mixing Tank: Doppler Settling Measurements • Independent field-based test of ADV-measured settling velocity

More Related