1 / 17

Eric Miller August 3 rd , 2010 Dr. Camberato & Dr. Nielsen

Variability of Maize Canopy Reflectance within Field-Length Strips Fertilized With Low to High Rates of Nitrogen. Eric Miller August 3 rd , 2010 Dr. Camberato & Dr. Nielsen. http://www.agry.purdue.edu/intranet/images/logos/Grey-logo.jpg.

marva
Download Presentation

Eric Miller August 3 rd , 2010 Dr. Camberato & Dr. Nielsen

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Variability of Maize Canopy Reflectance within Field-Length Strips Fertilized With Low to High Rates of Nitrogen Eric Miller August 3rd, 2010 Dr. Camberato & Dr. Nielsen http://www.agry.purdue.edu/intranet/images/logos/Grey-logo.jpg http://www.agry.purdue.edu/intranet/images/logos/Purdue-logo.jpg

  2. Research objective • Do “Virtual Reference Strips” occur in under-fertilized corn?

  3. Virtual Reference Strip • OptRx calibration process • 1/3 – 1/2 estimated total N consumed • Suggested pre-plant N rates: • 67 - 90 kg N ha-1 Corn following Soybean • 90 - 112 kg N ha-1 Corn following Corn

  4. Virtual Reference scan consists of driving for five minutes over the tallest, greenest plants in the field • Vegetative Index Reference Value

  5. Project Description • 2006 - 2009 • 6 Purdue Agricultural Centers • 32 site years 2006, 2007, 2008 and 2009: 19 CS and 13 CC • Plots range in size from 120 m – 550 m in length • Starter + sidedress with 28% UAN at six rates from 0 – 286 kg N ha-1 • Crop Circle ACS-210 were run 14 – 25 days after N application • Single hybrid/near-isoline was planted 2006 - 2008

  6. Relative CI well correlated with rel. yieldover 23 site-years 2006: ACRE, DPAC, NEPAC, PPAC, SEPAC (all C/S) 2007: ACRE, DPAC, NEPAC (C/S and C/C) 2008: ACRE, DPAC, NEPAC, PPAC, SEPAC, TPAC (C/S and C/C) * Normalized to values of highest N rate in each rep

  7. Sensor Measurements • 2 ACS-210 sensors • 4 mph, 40,000 hz, 38,400 baud rate • Recording data every 18 cm • Partitioned data into 30 and 60 sec runs • Approx. 3,500 30-sec runs/305 m

  8. Few 30 sec. runs of CI equal to RefCI C/S rotation, sidedressed with 90 kg N/ha, V9-V10 sensor readings Optimum N rate, kg/ha 232 204 225 167 190 169

  9. Throckmorton Purdue Ag Center • 305 m long plots, 12 rows, 76 cm wide • V-stage: V10 • Sensor Data Collected: July 8th • Hybrid: Pioneer Brand ‘33F88’ • Population Density: 81,500 plants ha-1 • Dominant Soil: Throckmorton- Fine-silty, mixed, superactive, mesic Mollic Oxyaquic Hapludalfs • Precipitation during growing season: 25 cm • Planted: May 24th Previous Crop: Soybean • Fertilized: June 24th

  10. Yield Response

  11. Avg. CI = 4.77 30 second runs = 53 meters of row With 114 kg N ha-1(68% of optimum N rate) 17% ≥ CI 4.77 Frequency, % Starter only (14% of optimum N rate) 2% ≥ CI 4.77

  12. Location of CI = RefCI 114 kg N ha-1 24 kg N ha-1 77 131 130 77 84 67

  13. Davis Purdue Ag Center • 365 m long plots, 12 rows, 76 cm wide • V-stage: V10 • Sensor Data Collected: July 9th • Hybrid: Pioneer Brand ‘33F88’ • Population Density: 81,500 plants/ha • Dominant Soils: Blount- Fine, illitic, mesic Aeric Epiaqualfs Pewamo- Fine, mixed, active, mesic Typic Argiaquolls • Precipitation during growing season: 37 cm • Planted: May 26th Previous Crop: Soybean • Fertilized: June 15th

  14. Yield Response

  15. Avg. CI = 4.00 30 second runs = 53 meters of row Frequency, % 54% of optimum N rate 38% ≥ CI 4.00 34 % of optimum N rate 16% ≥ CI 4.00

  16. Conclusions • Few areas of a field fertilized with 50-70% of the optimum N requirement had CI equal to or greater than the reference CI. • Areas with CI ≥ ref. CI were small, generally less than 200 m and 2 minutes in length. • Could we have found these areas without previously running the sensors? • Would these areas identified in 2009 continue to be ≥ ref. CI?

  17. Questions?

More Related