1 / 26

GENTLEsilence LUX 8000 B

GENTLEsilence LUX 8000 B. ... fascinating silence. KaVo GENTLEsilence 8000 fascinating silence. Noise creates stress and under long term impact it damages the human health. Especially during concentrated work like a dentist does.

wwynn
Download Presentation

GENTLEsilence LUX 8000 B

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GENTLEsilence LUX 8000 B GENTLEsilence LUX 8000 B ... fascinating silence

  2. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinating silence Noise creates stress and under long term impact it damages the human health. Especially during concentrated work like a dentist does. That‘s why it has always been a challenge for KaVo to reduce the noise level of KaVo turbine handpieces simultaneously to all the other high tech innovations: KaVo development of noise reduction: 1958 : KaVo Borden-Air 58 78 dB(A) 1970 : KaVo Super All-air 618 75 dB(A) 1977 : KaVo SUPERtorque 630 68 dB(A) 1989 : KaVo SUPERtorque 640 65 dB(A) 2001 : KaVo GENTLEforce 7000 62 dB(A) 2005 : KaVo GENTLEsilence 8000 57 dB(A)

  3. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinating silence Noise level = acoustic pressure + frequency Acoustic pressure (loudness) is measured in Decibel dB (A) and ranges in a progressive scale from 0 to 140 dB (A). The parameters of Decibel- measurement for turbine hand-pieces are well-defined in norm EN ISO 7785-1. (e.g.: measuring distance 45 cm) Only data, which are measured under this EN ISO- norm are objectively comparable. Threshold of pain

  4. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinating silence Acoustic pressure dB(A) Humans sense a reduction of the acoustic pressure by 8- 10 decibel as a bisection of the loudness SUPERtorque 640 65 dB(A) GENTLEsilence 8000 57 dB(A) present turbines

  5. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinating silence Noise level = acoustic pressure + frequency Frequency ( tone / sound ) is measured in Hertz (Hz) and describes the vibration frequency ( rise and fall of acoustic pressure ) per second. Human ears can sense sounds at frequencies from 16 – 16,000 Hz. We are sensing high frequency sounds as very unpleasant and even painful. Low frequency tones we sense as particularly loud.

  6. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinating silence In addition to the reduction of the acoustic pressure ( 57 dB(A) ) we also found a solution to eliminate the high- frequency peaks by using a new technology for fixing the ball bearings on the chuck pleasant to the ear – pleasant for the nerves Basic- frequency : 6 kHz

  7. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinating silence • By using a new technology of ball • bearings with a one-piece inner ring • an extremly well balanced turbine- • cartridge guarantees vibration- free • performance at only 57 dB(A) with a fascinatingly quiet sound- level • KaVo added values: • fascinatingly quiet sound level • vibration- free performance • long-term durability • Repair service by exchange of the • ball bearings is not possible.

  8. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinatingly quiet – amazing powerful GENTLEsilence cartridge- design with KaVo original ceramic ball- bearings guarantees longevity with excellent power output: 19 Watt at approx. 200.000 rpm( Idling speed: 360.000 rpm) This excellent power output already is available at an air pressure of only 2.6 bar / 37 psi.

  9. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000fascinatingly quiet – amazing powerful automatically regulated air pressure 2,6 bar: 19 Watt power output Even if the air pressure is lower, GENTLEsilence offers more power

  10. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000ingenious angle combination Patented KaVo angle combination creates more freedom of movement : head angle 100° and knee angle 19°

  11. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000ingenious angle combination Freedom of movement by perfect angle combination, coordinated design and smallest headsize unimpeded work – exact preparation – gentler treatment • Conventional turbine handpieces • Working space in molar area often too tight • Limitation due to contact with • anterior teeth GENTLEsilence 8000 Excellent working space due to perfect angle combination and smallest headsize.

  12. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000freedom of movement in the premium class GENTLEsilence head housing: smallest of its class

  13. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 freedom of movement with 19 mm FG-bur

  14. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 freedom of movement

  15. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Sensitivity for precision Sensitivity and tactile- feeling through KaVo Plasmatec- coating and optimized material : grip- sleeve made of stainless steel • improved grip - unique handling

  16. Basic-material Plasma GENTLEsilence steel sleeve GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Sensitivity for precision KaVo Plasmatec coating-process : PVD - Physical Vapor Deposition Through a light-arch at a temperature of approx. 10,000 0 C the basic material changes his physical aggregate state up to the 4th level – PLASMA. At a temperature of 250 0 – 300 0 C the plasma, which is mixed with inert gas, falls on the surface of the GENTLEsilence sheath. Metal-ceramic surface which is twice as hard as stainless steel

  17. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Sensitivity for precision Plasmatec coating-process :KaVo Hygiene Seal- coating After PVD-processing the metal-ceramic surface will be finished in a special-process with a second coating : KaVo Hygiene Seal-coating • The surface with human touch • improved grip • more sensitivity • enhanced hygiene

  18. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 automated optimal Integrated pressure-regulation-valve for automated adaption to the optimal air pressure ( 2.6 bar / 37 psi ) • optimum power usage and best longevity of the cartridge 2, 6 bar 37 psi

  19. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 clean and hygienic Anti-Suck-Back due to unique KaVo cartridge-design which prevents contaminated particles and dirt to enter the head housing. GENTLEsilence 8000 Conventional cartridges Over-pressure build-up during runing-out time of cartridge - no chance to enter Low-pressure build-up with suck- back effect during runing-out time of cartridge

  20. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 reliable clean Exchangeable microfilter in spray-water channel guarantees efficient and reliable spray- cooling at all times. easily exchangeable by the assistant

  21. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 optimal cooling Optimal cooling of the bur through 4- hole spray with finest spray coverage all the way to the bur- tip Spray cooling : 15 – 25 mm

  22. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 powerful and safe KaVo push-button-system guarantees safe and strong grip of the bur with excellent handling-comfort Holding strength of chuck-system: 32 N Burs: shaft diameter: 1.59–1.60 mm cutting diameter: max. 2.0mm total length : max . 25 mm ( norm DIN EN ISO 1797-1 )

  23. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 always high visibility Glas-Rod Cellular Optics ( 25,000 LUX ) – best illumination of preparation- area without degredation of light transmission even after 1,000 sterilization cycles and more

  24. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 MULTIflexible KaVo MULTIflex-System • universal • MULTIflexible • futuristic

  25. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Hygiene without risk • washable in Thermo-disinfector • sterilisable up to 1350 C / 275° F

  26. GENTLEsilence LUX 8000 B KaVo GENTLEsilence 8000 Thank you for your attention

More Related