1 / 31

High-Fidelity Josephson qubit gates – winning a battle against decoherence

High-Fidelity Josephson qubit gates – winning a battle against decoherence. Racah Institute of Physics Colloquium, Nov. 2007. Nadav Katz Work done while at UCSB with Prof. John Martinis and group. “Quantum Integrated Circuit” – scalable New breakthroughs: Improved fidelity

xaria
Download Presentation

High-Fidelity Josephson qubit gates – winning a battle against decoherence

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High-Fidelity Josephson qubit gates – winning a battle against decoherence Racah Institute of Physics Colloquium, Nov. 2007 Nadav Katz Work done while at UCSB with Prof. John Martinis and group. • “Quantum Integrated Circuit” – scalable • New breakthroughs: • Improved fidelity • Universal gates, with tomography • 50 qubit – easy to couple Contact: katzn@phys.huji.ac.il Ext: 84133

  2. Experimental Quantum Information Processing (QIP) a perplexing explosion of different systems

  3. Smaller Bigger Easier to isolate Easier to couple & construct Ions Neutral Atoms NMR Semiconductor Spins Quantum Dots Superconducting Circuits Experimental QIP – a guide for the perplexed • Dots: LONG T1 (T2?) • Coherent Oscillations • NMR: 2 to 7 qubits; • scalability? • Ions: up to 8 qubits & scalable • No dissipation • Pretty good coherence times • Coupled qubits • Decoherence?? Goal - reach the fault tolerant threshold – F > 99.95%

  4. The Josephson Junction SC “Josephson Phase” ~1nm barrier SC Electrical notation Josephson junction Idc Al bottom electrode AlOx tunnel barrier Silicon or sapphire substrate Al top electrode

  5. The Qubit (phase) I Idc C R V . Kirchoff’s Laws: Idc + C V + V / R = I equation of motion Controllable “kinetic” energy damping potential energy Quantize ( is an operator)… Transform to Hamiltonian rep.

  6. Superconducting Qubits Phase Flux Charge Yale, Saclay, NEC, Chalmers UCSB, NIST, Maryland, Wisconsin, Jerusalem Delft, IBM, Berkeley 102 1 104 Area (µm2): 10-100 (1) 0.1-1 0.01 Potential & wavefunction Engineering ZJ=1/10C 30  103 105

  7. Our Qubit SQUID microwave drive Junction inductor Flux bias Idc Iµw Qubit SQUID VSQ Flux bias ~ 100 microns

  8. Operation of the Phase Qubit Qubit basis states |0, |1 Flux bias Idc Iµw |1 Qubit |0 10 SQUID VSQ Measure state occupation by selective tunneling Tune qubit state energies E10 with dc current Idc Control qubit states with microwave current Iµwat 10 Minimize fluctuations and dissipation for qubit coherence

  9. potential U Josephson-junction qubit (1) State Preparation Wait t > 1/10for decay to |0> |1> |0> phase (2) Qubit logic with current bias dIp(t) I = Idc + dIp(t) + Imwc(t)cosw10t+ Imws(t)sinw10t (3) State Measurement: U(Idc+dIp) Fast single shot – high fidelity I mwc I mws |0> |1> 3 ns Gaussian pulse 96% Prob. Tunnel • |1> : tunnel • |0> : no tunnel pulse height of dIp

  10. X Y Imw Z Ip Reset Compute Meas.Readout time If Repeat 1000x Probability 0,1 Is 1 0 Vs Is Vs If Sequencer & Timer 300K V source ~10ppm noise ExperimentalApparatus rf filters fiber optics V source Ip ~10ppm noise Z, measure Imw X, Y I-Q switch mwaves 20dB 20dB ~5 ns pulses 4K 20mK mw filters 20dB 10ns 3ns 30dB

  11. mw 14 bits, 2x Gs/s FPGA memory, ~2k$ I Q GHz DAC Electronics Old analog system: mwave amplitude measured waveform time (ns)

  12. Spectroscopy 6 2 Imw saturate Ip meas. 10(I) P1 = grayscale Bias current I (au)

  13. x lifetime time Qubit Characterization Rabi Meas. time 1 T1 ~450ns 0 P1 T~100ns x/2 x/2 Ramsey time 1 T2~350ns y x/2 x/2 Echo time 0 0 100 200 300 400 500 600 time [ns]

  14. Standard State Tomography (Z, Y, X meas.) X Y/2 Y I,X,Y P1 Z I State prep. time (ns)

  15. Measurement in detail  pulse Imw Idc p~1 p=0.5 Full measurement (p=1) projects to either or Question: What is the quantum state after a partialmeasurement (p<1) ?

  16. Partial measurement evolution Answer: Theory: A. Korotkov, UCR Following Dalibard et al. PRL 68, 580 (1992). Prob. = 1-p/2 tunnel out Prob. = p/2 Apply state tomography to test theory

  17. Partial measurement - results High fidelity z rotations But can the effect of such a partial measurement be undone?

  18. partial measure p partial measure p state preparation x tomography & final measure Iw p p Iz t 10 ns 10 ns 7 ns 7 ns Quantum erasure Partial measure Probablistic recovery of quantum state even with strong measurement Erasure Nontrivial sequence – Very good control Erasure (0.9) Process tomography of the erasure (~85% fidelity)

  19. Coupled Qubits Straightforward to implement: simple coupling tunable fast readout simultaneous measurement Cc C Cc On Resonance: 11 01 10 00 eg. UMaryland

  20. Simultaneous Measure of Coupled Qubits: i-SWAP gate p PAB tosc P10 A /2 z-gate B P01 Eigenstate, Bell singlet P11 S 11 01 10 z-gate p 00 i-SWAP gate

  21. Tomography: Direct Proof of Entanglement state tomography p I,X,Y p/2 A I,X,Y B fidelity = 0.86 expect = 0.87

  22. Process Tomography state tomography p I,X,Y i-swap A (i-swap)1/2 is a universal gate I,X,Y B Samples Bloch sphere enough to describe gate for ANY initial state 4 initial states / qubit

  23. Process Tomography 16 Density Matrices: Data (3 min.)

  24. Preliminary Data Re [] Im [] Fidelity: Tr(thy exp) = 0.427 DATA T1 = 450ns CM = 8% CuW= 5% vis = 85% g/π = 20MHz SIM

  25. Qubit Coherence: Where’s the Problem? Capacitors Inductors & Junctions Circuits Energy eV 2D~4Tc resonator D. of States (X-tal) (amorphous) Superconductors: Gap protects from dissipation X-tal or amorphous metal Protected from magnetic defects Good circuit design (uwave eng.) Many low-E states Only see at low T

  26. 1st gen. Qubit Improvements(dielectric loss) 40% T1 = 40 ns 2nd gen. No Si wafer SiO2 -> SiNx P1 (probability) T1 = 500 ns 60% 3rd gen. Small junction + shunting C SiNx capacitor 60 m T1 = 110 ns 90% (loss of SiNx limits T1) tRabi (ns)

  27. New Qubit Data 90% 4th gen. P1 (probability) T1 = 470 ns T  ~ 300 ns Interdigitated C – (topologically protected) sapphire dielectric (radiation from large size?) tRabi (ns) a-Si:H dielectric (Q ~ 40000) 5th gen. T1 = 450 ns • Optimistic for further dramatic improvements • We know crystals are “superinsulators” • How to fabricate?

  28. TLS Resonance – not a bug, a feature… • Strong interaction with TLS (S = 40MHz) • Long-lived TLS is quantum memory “on” excite qubit off-resonance Frequency • On-Off coupling with change in bias z-pulse into resonance “off” Tswap ~ 12ns Bias X interact with TLS measure P1 8% time [ns] off TLS on 16 ns time time [s] T1,TLS ~ 1.2s X swap hold swap P1 off TLS on 16 ns 12 ns time 12 ns time [s]

  29. init store mem load TLS 16 ns 16ns 12 ns 12 ns 1 2 3 Quantum Memory with Process Tomography Process tomography: identity operation dominates process Fidelity: Tr(thmeas) = 79% 1 – Initialize Create states over the entire Bloch sphere. 2 – Store Swap state into TLS. Qubit now in ground state. 3 – Load After holding for 16ns, swap again to retrieve state from TLS.

  30. New Frontier: 50atoms • “Atom” with 50 W impedance • |Zqubit| =1/w10C atoms phase qubit Zqubit () F Q 1M 1K 1 377 50 Z mismatch makes coherence easier Z match makes coupling easier • 50  enables long distance coupling • Much better error threshold ! Architecture Error threshold Unlimited range 10-3 – 10-4 2D lattice nearest-neighbor 10-5 1D lattice nearest-neighbor 10-8

  31. Future Prospects • Demonstrated basic qubit operations • Initialize, gate operations, controlled measurement • 10 to 100 logic operations Tomography conclusively demonstrates entanglement • Decoherence mechanism understood • Optimize dielectrics, expect future improvements • Problem is NOT (only) T1 !! • Future: tunable coupling, CNOT gate with process tomography • New designs and regimes (cavity QED and microbridges) • Scale-up infrastructure designed (“brute force” to ~40 qubits) Very optimistic about 4 -10 qubit quantum computer

More Related