1 / 5

HPLC system

This HPLC system is equipped with high-pressure constant-current pump and UV detector. <br>Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors <br>helps in identification of samples and elutes that are colourless, odourless in nature. <br>There is auto boot detection function available in this HPLC system.

Eleanor96
Download Presentation

HPLC system

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Personalized PDF Catalog Catalog Generated On : 12/01/2024 HPLC system https://www.labtron.co/ | info@labtron.co Description : This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system.

  2. Specifications : High pressure Single pump pump Flow rate 0.001 - 9.999 mL / min (0.001 mL / min increment) range Pressure ≤ 0.5 MPa (0 - 42 MPa) range Flow rate RSD < 0.06 % precision Pulsation ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa) Qualitativ RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) e analysis Quantitati ve RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) repeatabil ity Flow rate setting Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature) error Mixing ± 1 % accuracy

  3. Mixing ± 0.2 % precision Size (W × 450 × 300 × 160 mm H × D) S iz e Fl Spect Bas Wavel Bas Wavel Limit ( Wavel o rum elin ength elin ength of W ength w band e accur e precisi detecti × range ce widt nois acy drift on on H ll h e × D ) 4 UV 5 Detector 3 × 0 ≤ ± ≤ ± 10-9 g / × 0.25 0.4 mL 3 × × 190 - 8 (napht 0 10-5 ± 1 10-4 < 0.1 680 µ 8 nm halene 0 AU nm AU nm nm L methyl × (em (em alcohol 1 pty pty solvent 6 cell) cell) ) 0 m m

  4. Features : Limit baseline noise can be ensured using electronic pulse suppression technique High pressure single pump Easy to change gasket ring & automatic washing function for the column User-friendly software for smooth operations Applications : The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

  5. www.labtron.co Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom Email: info@labtron.co | Website: https://www.labtron.co/ | Phone: +44 2080 043 608

More Related