1. S.S. Rajput 1 Cost Effective Modernization – Application of Science & Technology in Bank Security
BY
S. S. RAJPUT
Security Engineers Private Limited
109/5A, Hazra Road, Kolkata – 700 026
Phone (033) 2454 6764/3092 5072 ,
Fax : (033) 24546440, E-mail : rajputs@vsnl.com
Web site : www.seplsecurity.com
2. S.S. Rajput 2
3. S.S. Rajput 3 SCOPE OF TALK IS LIMITED TO : Security Alarm
Fire Alarm
C C T V
Time Lock
Auto Dialer
Access Control
Integration and Networking
Metal Detectors
Cash Bag Alarm System
4. S.S. Rajput 4 PRODUCTS Security Alarm Fire Alarm
5. S.S. Rajput 5 CCTV SYSTEM
6. S.S. Rajput 6 Time Lock System
7. S.S. Rajput 7 Time Lock System
8. S.S. Rajput 8 Access Control
9. S.S. Rajput 9 Access (Perimeter) Control
10. S.S. Rajput 10 Access (Door) Control
11. S.S. Rajput 11 Access (Gate) Control
12. S.S. Rajput 12 Access (Perimeter Door) Control
13. S.S. Rajput 13 Access (Sliding Door) Control
14. S.S. Rajput 14 Access (Perimeter) Control
15. S.S. Rajput 15 Access (Gate) Control
16. S.S. Rajput 16 Misc. Items
17. S.S. Rajput 17 Auto Dialing Alarm System
18. S.S. Rajput 18 Products are changing normally very slowly but the technology is changing very fast. Basically there are three parts of every Alarm System/
Security products
Master Controller
Input Devices
Output Devices
Input Devices Output Devices
19. S.S. Rajput 19 Input
Devices Output Devices
(Sensors) Audio / Visual
Indicators
Electronic Devices
(I.e. auto dialer etc.)
Cameras,
Automatic door
closure, Power
On / Off etc.
20. S.S. Rajput 20 Output Devices
Audio: Hooters
Siren (Motorized)
Recorded voice through amplifier
Video: Flasher
Displays – Electrical
- Electronic
Others Sprinklers
CO2 Flooding
Hydrant
Other different type of Communication through cable and Cordless.
21. S.S. Rajput 21 Let us talk about the technology : Security / Fire Alarm :
(a) Manual or Mechanical Siren.
(b) Electrical (Motorized) Siren.
(c) Electronic Siren.
(d) Motorized Siren / Electronic Hooter are controlled by Master Controller.
Change in Technology used for sounder
i.e. from Manual to Electronic.
22. S.S. Rajput 22 Change in Technology used for MC (Master Controller) I.e. from (A) Active Components : Vaccum Tubes (Valves)
Transistors
IC (Integrated Circuits)
Microprocessors + EPROMS
Micro Controllers
Embedded Technology
23. S.S. Rajput 23 (B) Passive Components :
Like : Resistors
Capacitors etc.
Form Normal to SMD / SMT (Surface Mount Technology)
(C) Power Supply :
(I) Dry Cell Ni-cd & Lithium
(ii)Lead Acid type (Secondary Battery)
(a) Normal, Automotive
(b) Sealed Maintenance Free
(iii) Bio Gas
(iv) Petroleum Energy (Diesel Generator etc.)
(v) Thermal Power
(vi) Hydroelectric Power
(vii) Nuclear Power
(viii) Solar Power
24. S.S. Rajput 24 The Components of Various types of Security / Fire Alarm System : Security Alarm System : (a) Master Controller
(b) Input Devices
(c) Output Devices.
Feature of Security Alarm Master Controller.
Feature of Fire Alarm Master Controller.
25. S.S. Rajput 25 Input devices for Security /Fire Alarm System : Types of Sensors / Detectors.
(a) Panic Switches – Hand operated
Foot operated
Wired Wireless
H.O. H.O.
F.O. F.O
(b) PIR ? Standard
? Pet Immune
? Dual Tech (IR + Micro wave)
IR ? Transmitter & Receiver
? Directional, Straight line
? Curtain type.
26. S.S. Rajput 26 Magnetic Sensors – Different Size and shapes
According to application.
Light Sensors / Optical Sensors.
Pressure Sensors
Proximity Sensors RFID
Biometric Sensors Optical
(Fingers, Facial etc) Optical + Heat
Fire Sensors Smoke Optical & Ionization
Heat Fixed Temp. &
Rate of rise
Flame Infrared
Sensors Ultra Voilet
Ultra Sonic Sensors
Microwave Sensors
Vibration and shock sensors.
Others Misc.
27. S.S. Rajput 27 Other Electronic Devices Auto Dialer
Motorized door closures power on / off
Cameras
Networking with computer.
28. S.S. Rajput 28 BANK Definition : A financial establishment that uses money deposited by customers for investment , pays it out when required, make loans at interest and exchange currency.
Origin : From French – Banque
Itallic - Banca
Latin - Bancus
Related to bank & bench
(Denoting a money dealers table / bench)
29. S.S. Rajput 29 SECURITY Definition : The state of being or feeling secure.
Origin : Secure from Latin work Securas
Se + Cura
Without Care
30. S.S. Rajput 30 SCIENCE Definition : Systematically organized body of knowledge on any subject.
Origin : Latin word “SCIENTIA”
means
KNOW
31. S.S. Rajput 31 TECHNOLOGY Definition : The application of scientific knowledge for practical purposes.
Origin : Greek – Tekhnologia
tekhne logia
means
Art, Craft Heavy (Deep Study/
Interest)
32. S.S. Rajput 32 Fire Detection cum Alarm System Master Control Panel Unit.
Rechargeable maintenance free batteries, 01 No., 07 AH. 12-V.
Detectors :
Ionisation Smoke Detectors
Optical Smoke Detectors
Rate of Rise-cum-Fixed Temp.
Heat Detectors
Response Indicators
Manual Call Points
Electronic hooter
Cable (armoured) , Conduit PVC pipe.
All the above components & equipments are inter connected through copper conductor armoured cable.
33. S.S. Rajput 33 Fire Detection cum Alarm System CONTROL PANEL :
Supply and installation of wall mounting type Microcontroller based 8 zone master control panel enclosed in 1.6 mm CRCA Sheet casing for fire detection & alarm system with clear front glass vision and locking up arrangement with adequate paint and polish and having following annunciations as per IS : 2189 of 1988.
a) Normal LED (6.26). This will show that the individual zone is working normally.
b) ‘Open’ LED (6,4). This will indicate that there is some sort of disconnection in the particular zone / circuit.
c) ‘Short’ LED (6.4). This will indicate that there is a short circuit in the particular zone.
34. S.S. Rajput 34 Fire Detection cum Alarm System d) ‘Battery fail’ LED (7.7). This will indicate the battery condition being healthy or otherwise.
e) Flashing ‘Fire’ LEDs (6.33.4). There will be two such LEDs in parallel connection which will indicate a fire in a particular zone.
f) Common zone ‘Test’ switch - This switch enables to test all the zones simultaneously.
g) Individual zone ‘Test &6.33 4h) This switch enables to test any particular zone.
35. S.S. Rajput 35 Fire Detection cum Alarm System
h) Alarm ‘acknowledge’ switch (6.8) In case the protected place is manned, and an alarm starts, he will have an opportunity for 10-15 seconds to hold on the automatic operations such as discharge of CO2, gas Auto dialing of police station / Fire brigade etc. by pressing this switch and can manually initiate such actions, should these be necessary as and when he wants. While in case of absence of the man all actions will be taken by the system automatically after 10/15 seconds. After acknowledging, the flickering of FIRE LEDs will come stand still and also the sound will change indicating that somebody is attending to the emergency.
36. S.S. Rajput 36 Fire Detection cum Alarm System i) ‘Reset’ switch (6.17) This switch will reset the system to normal condition for continuing vigilance a new .
j) Zone ‘isolation’ switch - This switch enables to isolate a zone in case of need / fault while all other zones will work normally. The isolated zone will show ‘open’ when so isolated.
k) Automatic electricity disarming contact (zero potential) (6.6) This will give a zero potential contact for auto isolation of electricity in the protected area. This must be done instantaneously.
l) Automatic system actuation signal (24 V) (6.6) There will be an automatic 24V signal of actuating allied accessories such as Carbon dioxide gas discharge / Automatic telephonic message to Police Station / Fire Brigade etc.
37. S.S. Rajput 37 Fire Detection cum Alarm System m) ‘Hooter isolation’ switch (6.8) This switch will isolate the hooter to avoid commotion during testing.
n) D C volt & Ampere meters (6.33.4) This will show the operating voltage and amperage.
o) External terminals and fuses for easy interchange and checking.
p) ‘Power On/Off’ switch for putting the system ‘on’ or ‘off’.
All switches / LEDs will be under lock & key except the ‘Alarm acknowledge’. ‘Sensor reset’ and ‘System reset’ switches.
38. S.S. Rajput 38 Fire Detection cum Alarm System DETECTORS
Detectors shall be dual chamber ionization type, Apollo make, Operating under 12 Volts, approved by FM / UL. To be supplied wide imported base Heat, Optical and other detectors should also have the above approval and of same make.
REMOTE INDICATORS
Locally made, to be encased in metal box 75 mm X 75 mm or less, properly painted and marked ‘FIRE’.
ELECTRONIC HOOTER
The electronic hooter should work under 12 volts minimum 6 watts capacity should have wailing sound.
39. S.S. Rajput 39 Fire Detection cum Alarm System BATTERY
1 x 12 Volts maintenance free lead-acid battery of ‘EXIDE’ make. This should have the capacity to energies the system for 96 hours continuously or 7AH each whichever is more. The batteries will be kept inside the panel itself.
WIRING & CIRCUITS
a) Wiring for the ‘Zones’ detection line will be of 1.5 mm, 2 core copper armoured PVC cable conforming to IS:1554 (Part-I) – 1976 with ISI mark, properly clamped at every 8 inches. The cables should be laid in terms of clause 8 of IS:2189-1988.
b) In case false ceiling is inaccessible 1.5 mm, 2 core, copper, FRLS cables in 1” PVC, ISI marked conduit may be used.
40. S.S. Rajput 40 Fire Detection cum Alarm System
41. S.S. Rajput 41 Fire Detection cum Alarm System
42. S.S. Rajput 42 Integrated Alarm System SPECIFICATION FOR INTEGRATED ALARM SYSTEM
1. It must be compact (15” x 10” x 6”) size maximum, powder coated decent look, steel metal cabinet. Mains cum battery operated. Battery backup 12v rechargeable maintenance free.
2. Technology used must be latest as micro controllers / Embedded Technology / Surface Mount Technology, PCB of PTH type only.
43. S.S. Rajput 43 Integrated Alarm System SPECIFICATION FOR INTEGRATED ALARM SYSTEM
It must be compact (15” x 10” x 6”) size maximum, powder coated decent look, steel metal cabinet. Mains cum battery operated. Battery backup 12v rechargeable maintenance free.
Technology used must be latest as micro controllers / Embedded Technology / Surface Mount Technology, PCB of PTH type only.
44. S.S. Rajput 44 Integrated Alarm System 3 Control Panel
Should of minimum four zone. Each zone must be expandable up to 5/6 zones.
Each zone should be auto isolated.
Day / Night facility & auto change over from Day to Night & Night to Day mode.
Self testing of the system including motorised Siren for 2 seconds after changeover from Night mode to Day mode.
45. S.S. Rajput 45 Integrated Alarm System Delay facility up to 10 minutes should be made available.
Auto switch off & auto resetting after 10 minutes of operation.
Anti – rodent facility should be available.
System should activate after 1 to 1.5 seconds after pressing the panic switch to avoid any false switching.
Single switch test facility of the system.
Competable for any type of sensors i.e., PIR, Vibration Sensor, Smoke / Heat Sensor, Magnetic sensor etc.
Facility of Remote control / wireless switches for each zone separately.
Auto Dialer connectivity should be available.
46. S.S. Rajput 46 Integrated Alarm System Should be operated by any types of telephone from anywhere in the world.
It should have a 25 years digital calendar to programme the Alarm System for different type of timing and holidays. It should have auto mode (Day to night and night to day) change over facility. Auto testing facility for the entire system including sirens. At the time of change over from night to day mode. To insure the good health of the system.
Capability to to connected with CCTV System.
Should be ERTL tested.
Undertaking by the manufacturer that this can be networked with banks on computer network.
47. S.S. Rajput 47 Integrated Alarm System
48. S.S. Rajput 48 C C T V SYSTEM Master Controller : DVR Card for computer + software
DVR (Stand Alone ) + Software
Input Device : Cameras of different type depending upon their uses & locations.
Output Device Monitors, Hooters, etc.
Feature of DVR Card / DVR standalone system
Cameras – Black & White
- Colour
- PCB Mount
- ‘C’ Mount
Feature of Monitors CMOS Sensors 1/3”
CCD Sensors Ľ”
Shadow features of a Cameras
49. S.S. Rajput 49 C C T V SYSTEM
50. S.S. Rajput 50 Standard Cameras
51. S.S. Rajput 51 Camera Specifications
52. S.S. Rajput 52 Dome Cameras
53. S.S. Rajput 53 Misc. Cameras
54. S.S. Rajput 54 Misc. Cameras
55. S.S. Rajput 55 DVR (Standalone / Cards)
56. S.S. Rajput 56 ATM CCTV Live monitoring of video events
Recording - Continuous, Motion detection, Time based & sensor triggered recordings
Instant search of pre-recorded video by Time, Date, Camera # & Events
Image Authentication
ATM / POS Transaction data text overlay
Multi-level password protection to access system ensures high security
Backup in CD, DVD & other storage devices
Remote access & monitoring over networks (LAN/ WAN / PSTN / ISDN)
Remote Alert Notification of events
57. S.S. Rajput 57 ATM CCTV (Central Monitoring System) Central Monitoring Station is a revolutionary system that allows watching & controlling multiple remote locations simultaneously.
Total control of Remote Digital Surveillance System
Recording of video from remote
location
Enable/Disable cameras, recording schedule, setting of sensors over DVR Clients.
Remote search, save & playback of video at CMS site
Compatible with TCP/IP Protocol (PSTN, ISDN, ADSL, etc.)
Notification of events via E-Mail, Pager, Mobile phones
58. S.S. Rajput 58 4 Channel DVR Card 4 CAMERA - PROFESSIONAL HARDWARE COMPRESSION 60 / 120 FPS DVR CARD
M-PEG 4 Hardware Compression (4-120 Model)
Up to 4 Camera Inputs
High Resolution 352 X 240, 704 X 480 Video Modes
Two-way Audio With 4 Channels Audio Recording
Version 6 Advanced Software Package* Included
Operating Manual
BNC Pigtail Connector
Supports Windows 2000 and XP Professional
59. S.S. Rajput 59 Software features for DVR Card Two-way voice communication with audio recording
Ability to hide selected cameras from view while recording
Independent camera programming for video compression and type of recording method (motion or continuous)
User adjustable camera frame rate controls
J-PEG and M-PEG 4 video compression
Watermarking for law enforcement grade video authentication
High Resolution 352 X 240 and 704 X 480 video modes
Time & date stamping on video playback and video backup
Software zoom & image enhancement functions
Programmable video backup & automatic scheduling
422 / RS 232 control outputs
60. S.S. Rajput 60 Software features for DVR Card I/O Controls include 16 TTL inputs and 4 sensor outputs - time relay
Alarm system compatibility for external sensor inputs
Pan / Tilt / Zoom controls for Pelco and other cameras
Independent Pan / Tilt / Zoom password protected login
Single and multi-location remote viewing
Sensitivity controls for motion detection recording
Remote search, recording and playback
Selectable camera zone coverage with motion detection
Remote server configuration
Unlimited remote users with web browser
61. S.S. Rajput 61 Software features for DVR Card 16 camera simultaneous remote viewing by web browser and remote software.
Multi-level password administration
Virtual keyboard & mouse ability
Cash register integration
Programmable alert settings
E-Mail event notification
62. S.S. Rajput 62 4 Channel DVR Picture
63. S.S. Rajput 63 ACCESS CONTROL WHAT IS ACCESS CONTROL?
Access Control can be proximity, card swipe, digital keypads, hands free readers, biometrics, smart key, computer management, electric and electronic locking systems, timed access control.
Access Control might use telephone or video entry security, CCTV or alarms
Door, Gate and Barrier Access Control is the modern answer to property protection - DOMESTIC - COMMERCIAL - INDUSTRIAL
64. S.S. Rajput 64 ACCESS CONTROL 1. Master Controller – Standard Features
Input Devices – Cards, Biometrics, PIN Readers, Smart Cards etc.
Output Devices – Door Lock
- Light & others
65. S.S. Rajput 65 ACCESS CONTROL System features:
Upto 16 Proximity Reader.
Upto 16 Access Groups may be defined. Each Access Group is configured to have one or more (upto 8) Reader(s)
Each Reader of the Access Group may be assigned as IN Reader(s), OUT Reader(s) or NULL Reader(s)( Exit through Push Button)
Each Access Group can have Anti Pass Back feature enabled provided the Access Group consists of no NULL Reader.
Card Holder Database : Upto 2000
Visitor Database table : 100 cards
Transaction Data Storage : Last 5000 Records
66. S.S. Rajput 66 ACCESS CONTROL System features:
Holiday Database : 30 Holiday Dates
Weekly Off : Weekly off may be defined
Holiday/ Weekly Off Card Holder Database : 100 cards
Holiday Master Card : 8 Master Card
Micro Controller based design with Real Time Frame in Flash ROM, Watch Dog Timer, Lithium Battery backed up RAM
2X16 Digital Backlit LCD Display
PC Connectivity : RS232C /RS485 Port (Isolated)
16 Relay output for Access Control Application
SMPS Power Supply
67. S.S. Rajput 67 ACCESS CONTROL Hardware Specifications
CPU : 89C52@11MHz
Memory : 128 KB RAM (5000 Records Storage)
Watch Dog Timer : Yes
Battery Back-up : Clock & Data up to 10 years
Communication : RS 232C or RS485 (Isolated)
Data Upload Speed : 1000 Records/minute
Power : SMPS 170 V to 260V @ 50Hz+/-5Hz,2W
Relay O/p : 1 / 2 Potential Free/12V ontact o/p (XS/XL)
Dimension : 300(H) X 176 (W) X 80(D) mm
Mounting : Wall/Panel
Casing : Dust Resistant Corrosion Free, Metal Enclosure.
Operating Temp. : 0 – 50oC
Humidity : 0-98% RH
68. S.S. Rajput 68 Biometric Card
69. S.S. Rajput 69 ACCESS CONTROL
70. S.S. Rajput 70 TIME LOCK SYSTEM SPECIFICATION
It must be light, compact (maximum 5” x 5” x 4”) size suitable to be fitted inside main Strong room / Vault / Cash safe door. Lithium / Ni – cd battery operated. It should be independent of mains / electric power. Locking period – 199 hours minimum, LCD display. Technology used must be latest as Embedded Technology & Surface Mount Technology, PCB of PTH type etc. It must have Double operating system. If one fails another should open the Lock. Must be ERTL tested. No requirement of any extra lock. Only existing locks must be supported.
71. S.S. Rajput 71 TIME LOCK SYSTEM Bypass facility using 6/12 Digit personalized (changeable) code only & not by mechanical keys. Single / Double user facility should be optional. Bypass Keypad should be fitted any where in the branch & not on Strong room door to avoid main door drilling. A detachable keypad will be preferred for safety & security purpose. It should have delay facility up to 99 minutes with the Bypass Keypad only. Wrong combination penalty should be available.
72. S.S. Rajput 72 TIME LOCK SYSTEM
73. S.S. Rajput 73