McDonald’s Heated Landing Zone

McDonald’s Heated Landing Zone. The HLZ is designed to hold wrapped sandwiches while the meal order is completed. Five screws on the bottom of the unit secure the controller tower. Nuts holding the air tower diffuser in place should be loosened, not removed when dismantling the unit.

Download Presentation

McDonald’s Heated Landing Zone

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

  2. Five screws on the bottom of the unit secure the controller tower.

  3. Nuts holding the air tower diffuser in place should be loosened, not removed when dismantling the unit.

  4. The sealant on the seam of the heater plate must be cut prior to prying the plate off of its adhesive backing. Remove the plate when the unit is hot; the adhesive will be more pliable.

  5. Air RTD Air Thermocouple Relays Fuses

  6. Blower Assembly

  7. Air Heater

  8. Check temp. of heater plate / adjust setpoint Check temp. of air heater / adjust setpoint ON/OFF Programming switch Adjust setpoint

  9. The setpoint for the plate and the air heater can be changed: • With the unit off, press the Check button and then buttons • marked 1,2,3,3 in that sequence.

  10. SET will be displayed. • Press 1 to adjust heater plate; press 4 to adjust air temp. • Use UP (2) and DOWN (3) arrow keys to adjust setpoint.

  11. Press Check to lock in changes.

  12. The reliability of the HLZ’s temperature readouts can be checked. Test ports are positioned on the unit’s front panel, which allow independent measurement of the heater plate and air heater’s temperature. A variance of ± 50F between readout and meter is acceptable.

  13. COMPUTER 2 14 3 4 9 11 12 13 15 5 6 8 10 1 7 AIR RTD WHT RED BRN PLATE RED RTD AIR HEATER 12V WHT LOAD BLK PLATE HEATER + COM 208/240V + AIR HEAT PLATE HYPOT BLOWER RELAY RELAY RED BLK TEST POINT 240V OPTION WHT (CAP UNUSED WIRE GRN W/MALE PUSH-ON) 208V OPTION FUSE 2 4 0 LATCH BLOCK RELAY 1 8 6 GRN/Y BLK WHT TOP PLATE THERMOCOUPLE (TYPE K) RED WIRE TEST NEGATIVE PLUGS POWER AIR THERMOCOUPLE (TYPE K) BOTTOM CORD HLZ Wiring Diagram 0