UNIT 31 HOME ELECTRICAL SYSTEM

UNIT 31 HOME ELECTRICAL SYSTEM. NEC NATIONAL ELECTRICAL CODE. The National electrical code is a publication sponsored by the National Fire Protection Association. The NEC book includes recommendations and guidelines on wiring materials and methods. The NEC is updated every three years.

badu
Download Presentation

UNIT 31 HOME ELECTRICAL SYSTEM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UNIT 31HOME ELECTRICAL SYSTEM

  2. NECNATIONAL ELECTRICAL CODE • The National electrical code is a publication sponsored by the National Fire Protection Association.

  3. The NEC book includes recommendations and guidelines on wiring materials and methods. • The NEC is updated every three years.

  4. Electric Service Entrance • Is the part of the system that extends from electric company’s last transformer, to the breaker box of a house. • If the service runs above ground it is called a service drop. • If the service runs underground it is called a service lateral.

  5. Transformer on a pole S.E. Cable Used for the Service Drop

  6. HLP’s Step down transformer This transformer is used to supply a service lateral

  7. An electric service generally contains • A service entrance cable (SE cable) • A watthour meter • And a breaker box. (Load center)

  8. Watthour Meter Breaker Box Service entrance cable in conduit service lateral This conduit contains the wire the ties the Neutral Bus to the Ground Rod.

  9. THREE-WIRE SERVICE • A three wire serviceis used in order to supply two different voltages (120-240). • The SE cable has two current carrying conductors called ( Hot ) wires, and one noncurrent carrying conductorcalled ( Neutral ). • Hot wires are insulated, the neutral may be bare.

  10. The White Neutral wire and the Bare Ground wire are usually tied to the Neutral Bus Bar Neutral Bus Bar

  11. Neutral wire Hot wires

  12. Why supply two different voltages??? • $$$$$$$$$$$$ • It is cheaper to operate large amperage loads on 240 volts than 120 volts

  13. Example: An electric water heater uses 5500W heating elements. • Remembering I = P/E • 5500/120 = 45.833 A • 5500/240 = 22.91 A

  14. The lower current value is important for two reasons • The cost of installation, (smaller wire) is cheaper. • Power loss is directly proportional to the square of the current!!!

  15. The Watthour Meter • Records the amount energy used.

  16. The Load Center • Usually called a Breaker Box • Could be a fuse box • Contains the main disconnect, and usually several breakers or fuses. • Distributes the electricity to the many branch circuits throughout the building.

  17. The Service Ground • Is there to reduce the chance of shock and to protect against lightning. • The neutral wire of the SE cable is connected to a eight foot copper rod, driven into the ground eight foot deep. • The ground rod is connected to the neutral bus bar in the breaker box.

  18. BRANCH CIRCUITS • Branch circuitsdistribute the electricity from the breaker box to the different rooms of the building.

  19. General Purpose Branch Circuits 15 or 20 Amp Individual Branch Circuits 240V Larger Amperage Small Appliance Branch Circuits 20 Amp

  20. There are three types of branch circuits. • General-Purpose • Small-Appliance • Individual

  21. GENERAL-PURPOSE CIRCUITS • Are used for lighting and outlets. • Things like radios, TV’s, and small appliances (not kitchen appliances).

  22. SMALL-APPLIANCE CIRCUITS • Are dedicated for the kitchen only. • These outlets are for refrigerators, toasters, coffee makers, and any other of the 10,000 appliances that are found in our kitchens.

  23. INDIVIDUAL CICRUITS • Are used for only one piece of equipment (dryer, water heater, AC, and heater) • These loads are generally 240 volt loads. • A clothes washer and dish washer are only 120 volt loads but are require to be on an individual circuit.

  24. Wiring Branch circuits is usually done with these materials… • Nonmetallic Sheathed Cable • Armored Cable • Electrical Metallic Tubing

  25. Nonmetallic Sheathed cable ( ROMEX ) • NM cable is used for all kinds of indoor wiring. • Can not be exposed to sunlight, buried underground, in cement,or plaster. • Most common sizes are 14 And 12 AWG

  26. Romex • A style of wire that has two or three insulated conductors inside an outer cover of insulation called a sheath • It may or my not have a ground wire, which is usually bare( no insulation ) • 12/2, would indicate that there are 2 # 12 AWG wires in the cable. • 14/3wg, would indicate the there are 3 # 14 AWG wires in the cable as well as a ground wire.

  27. Neutral wire Hot wire Ground wire Sheathing

  28. Armored Cable • In armored cable, the insulated wires are in a flexible metal sheath.

  29. Metal sheath Hot wire Neutral wire Ground wire

  30. PVC conduit Safety Disconnect Weather-tight Flex conduit

  31. Electrical Metallic Tubing • Known as EMT • Is a thin wall metal pipe in which wires are pulled into, for protection while running through a building or outside the building.

  32. WIRING DEVICES • Switch boxes • Junction boxes • Connectors • Wire nuts

  33. Wiring devices are used to provide the safe, convenient, and reliable use and control of electricity. • All switches, receptacles, and splicing must be done or mounted in boxes.

  34. Switch box Junction box Cable connector Switch Conduit connector Receptacle Locknut

  35. GFCI receptacle A GFCI work by detecting the amount of current passing through the HOT wire and comparing the current to coming back on the Neutral wire. If as little as 5mA-7mA does not return on the neutral the GFCI will trip and must be reset.

  36. The minimum length of 6 inches individual wire is exposed

  37. A little slack in the Romex cable is a good thing…. Tape covering the splice in the Hot wire.

  38. Always curl the hook of a wire to be terminated under a screw head in the same direction as the screw tightens.

  39. The pig tail splice of the ground wires are tightly twisted and has 4 to 5 twist in the first inch.

  40. This little trick (at the end of the White wire) will help keep the braided wire bundled tightly and not spread out from underneath the screw head.

  41. This is how we terminate 2 different wires under 1 screw head. This is commonly called a pigtail splice

  42. Termination block for incoming voltage Natural Buss Bar

  43. THE END THE END THE END THE END