290 likes | 424 Views
6. Refrigerants and Refrigerant Oils. Learning Objectives. Prepare for the ASE Heating and Air Conditioning (A7) certification test content area “B” (Refrigeration System Component Diagnosis and Repair). Discuss the depletion of the ozone layer and the resulting issues of global warming.
E N D
6 Refrigerants and Refrigerant Oils
Learning Objectives • Prepare for the ASE Heating and Air Conditioning (A7) certification test content area “B” (Refrigeration System Component Diagnosis and Repair). • Discuss the depletion of the ozone layer and the resulting issues of global warming. • Explain the impact of legislative laws on automotive A/C systems. continued on next slide
Learning Objectives • Discuss identifying refrigerants and proper storage container. • State the changes considered for future refrigerants. • Explain refrigerant safety precautions. • Discuss the different types and viscosities of refrigerant oils.
Depletion of the Ozone Layer and the Resulting Issues of Global Warming • A chlorine atom from a chlorinated fluorocarbon (CFC) such as R-12 can travel into the stratosphere if it escapes or is released. • Under the effects of ice clouds and sunlight, it can combine with one of the oxygen atoms of an ozone molecule to form chlorine monoxide and an ordinary oxygen molecule, O2. • This destroys that ozone molecule.
Depletion of the Ozone Layer and the Resulting Issues of Global Warming • The chlorine can then break away and attack other ozone molecules. • It is believed that 1 chlorine atom can destroy 10,000 to 100,000 ozone molecules. • Global warming traps heat at the Earth’s surface and lower atmosphere, and it is increasing the temperature of our living area.
Figure 6–4 Chlorofluorocarbon molecules break apart in the atmosphere.
Impact of Legislative Laws on Automotive A/C Systems • Clean Air Act • Limit the production of ozone-depleting chemicals. • R-12 production in the United States ceased at the end of 1995.
Impact of Legislative Laws on Automotive A/C Systems • Section 609 • A portion of the Clean Air Act that places certain requirements on the mobile vehicle air conditioning (MVAC) service field. • Manufacture of HCFC-22 was stopped in 2010 in the United States and other developed countries.
Impact of Legislative Laws on Automotive A/C Systems • European R-134a Phase-out • The European Community wanted to reduce greenhouse gas (GHG) emissions. • Part of this legislation is to require that refrigerants must have a GWP of less than 150.
Impact of Legislative Laws on Automotive A/C Systems • Kyoto Protocol • Total Environmental Warming Impact (TEWI) index was developed, which rates the impact of various refrigerants along with the energy required to perform the cooling operation.
Figure 6–6 R-1234yf refrigerant is sold in white containers with a red stripe.
Refrigerants and Proper Storage Container • Refrigerants are commonly available in several sizes of containers including: • Small cans of 12 oz. to 14 oz. (400 g) • Larger drums or canisters of 15 lb. or 30 lb. (6.8 kg or 13.6 kg) • Refrigerant containers are color coded: • R-12 containers are white; R-22 containers are green; R-134a containers are light blue
Figure 6–1 Large 30 pound containers of R-134a are light blue for easy identification.
Figure 6–2 The stamped text at the top of this container reads “DOT-4BA400.”
Changes Considered for Future Refrigerants • TEWI • R-1234yf • R-744—Carbon dioxide (CO2)
Changes Considered for Future Refrigerants • Systems that use potentially hazardous refrigerants will probably use a secondary loop. • A heat exchanger will provide a very cold fluid to connect with a liquid-to-air heat exchanger that will replace the evaporator.
Figure 6–8 The label on a Toyota Fuel Cell Hybrid Vehicle (FCHV) showing that CO2 (R744) is being used as the refrigerant.
Figure 6–9 A secondary loop A/C system keeps the potentially dangerous or flammable refrigerant out of the passenger compartment by using a chiller/heat exchanger to cool an antifreeze and water mixture. This fluid then transfers heat from the cooling core in the air distribution section to the chiller.
Refrigerant Safety Precautions • Wear safety goggles or a clear face shield and protective clothing (gloves) when working with refrigerants. • Always be in a well-ventilated shop area when working with refrigerants and avoid small, enclosed areas.
Refrigerant Safety Precautions • If liquid refrigerant is splashed onto the skin or into the eyes of a human or animal, it immediately boils and absorbs heat from the body part it is in direct contact with. • If a CFC such as R-12 or R-22 comes into contact with a flame or heated metal, a poisonous gas similar to phosgene is formed.
Refrigerant Safety Precautions • Several flammable refrigerants have been marketed, and even though they have been banned and are illegal, they still show up. • When refrigerant containers are filled, room is left for expansion and the container is marked with its critical temperature, the maximum that it should be subjected to.
Figure 6–10 When recovering refrigerant, the container should be filled to a maximum of about 80%.
Different Types and Viscosities of Refrigerant Oils • Types of Refrigerant Oils • Mineral oil • PAG (polyalkylene glycol) • POE (polyol ester) • Refrigerant oils are commonly available in several viscosities, including: • 46; 100; 150
Figure 6–12 PAG oil is the type of refrigerant oil specified for use in most R-134a systems and the “150” is the viscosity.
Figure 6–13 This under hood decal gives a Mercedes-Benz part number (A 001 989 08 03) instead of the type and viscosity of refrigerant oil. Service information was needed to determine that it was PAG 46.
Summary • Refrigerants escaping into the atmosphere can have detrimental effects on the ozone layer and also increase climate change and global warming. • The Clean Air Act places requirements for technicians to follow when servicing mobile A/C systems. continued on next slide
Summary • Safety precautions should be followed when handling refrigerants. • Refrigerant oils are available in different viscosities and the specified oil must be used when servicing an air-conditioning system.