1 / 21

MEF Technical Committee Update

Agenda. MEF Technical Committee Process and Current WorkRepresentative projects Architecture: External Network to Network Interface (E-NNI), Phase 1Services: Class of Service (CoS) Implementation Agreement, Phase 1Management: Service OAM Fault and Performance Management Implementation Agreements

colleen
Download Presentation

MEF Technical Committee Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. MEF Technical Committee Update Bill Bjorkman VP, Co-Chair MEF Technical Committee bill@metroethernetforum.net

    2. Agenda MEF Technical Committee Process and Current Work Representative projects Architecture: External Network to Network Interface (E-NNI), Phase 1 Services: Class of Service (CoS) Implementation Agreement, Phase 1 Management: Service OAM Fault and Performance Management Implementation Agreements Q&A

    3. MEF Standards Process

    5. External Network to Network Interface

    6. Inter-Carrier Services via E-NNI

    7. E-NNI overview

    8. E-NNI Tunnels

    9. External Network to Network Interface

    10. Class of Service Implementation Agreement

    11. Carrier Ethernet CoS IA Reference and Scope

    12. Carrier Ethernet CoS IA Phase 1 Attributes CoS ID and Color Indication at UNI and E-NNI UNI: EVC+PCP or EVC+DSCP E-NNI: EVC+PCP or EVC+PCP+DEI 3 CoS Model: CoS Label High, Medium, Low Up to 3 CoS per EVC supported Performance Objective placeholders for Frame Delay, Frame Delay Variation and Frame Loss per CoS Label and per EVC Type Objectives will be mandatory when quantified and may be different for different EVC types PCP and DSCP values for CoS ID provided for MEF CoS Mandatory at E-NNI & recommended at UNI Additional Service Provider defined CoS allowed (e.g., Mobile Backhaul Use Case with 4th CoS) 3 of 8 PCP values not used in 3 CoS Model

    13. Carrier Ethernet Classes of Service Implementation Agreement, Phase 1

    14. Service OAM Implementation Agreements

    15. SOAM FM and PM Phase 1 Implementation Agreements Leverages standard OAM architecture and mechanisms for fault and performance management IEEE 802.1ag and ITU-T Y.1731 Specifies blueprint for supporting MEF services Specific Maintenance Domain levels Positioning of Maintenance End and Intermediate Points (MEPs and MIPs) Support for point-to-point and multipoint services FM: Continuity Check, Link Trace, Loopback PM: Monitoring of Frame Delay, Frame Delay Variation, Frame Loss Ratio and Availability

    16. Service OAM Fault Management Implementation Agreement

    17. Service OAM Performance Management Implementation Agreement

    18. Thank You Presentations are available at www.metroethernetforum.org Q&A

    19. Back-up

    21. Carrier Ethernet CoS IA Reference and Scope

More Related