WATER LEVEL MEASUREMENT

WATER LEVEL MEASUREMENT. Hydrography Skills Set Training Course No. 27743 June 2012. AN EARLY HISTORY. Originated in Ancient Egypt (3000 year s ago) - monitoring of Nile River water level for flood prediction

Download Presentation

WATER LEVEL MEASUREMENT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WATER LEVEL MEASUREMENT Hydrography Skills Set Training Course No. 27743 June 2012

  2. AN EARLY HISTORY Originated in Ancient Egypt (3000 year s ago) - monitoring of Nile River water level for flood prediction - approximately 20 recording stations (‘Nilometers’) were located - ‘Nilometer’ attached to temple walls, quays and the inside walls of temple annexes - units of measurement were ‘cubits’ (the measurement from the elbow to the tip of the middle finger, approximately 450mm to 530mm) - modern day methods of measurement have evolved from this primitive method of water level measurement

  3. Options for Water Level Measurement Manual Measurement Float Operation Submersible ‘Wet’ Pressure Sensor Gas Purge Operation

  4. Options for Water Level Measurement Manual Measurement

  5. Manual Measurement Contact Gauges Staff Gauge

  6. Manual Measurement DIP ZERO DEPTH The following example shows how depth of flow can be calculated by this method in a sewer. • From a fixed point a measurement is taken to water level (ie the ‘dip’) • This reading is subtracted from a known measurement (ie the ‘Zero’) • Depth = ‘Zero’ – ‘Dip’

  7. Manual Measurement Cantilevered Weight Gauge (Clear Ck at Golden, Colorado)

  8. Manual Measurement Maximum Height Indicator (Skokomish River, Washington).

  9. Options for Water Level Measurement Float Operation

  10. Float Operation

  11. Typical Shaft Encoders

  12. Options for Water Level Measurement Submersible ‘Wet’ Pressure Sensor

  13. Pressure Transducers – ‘Wet’ ‘Gauge’ Type (stainless steel) ‘Gauge’ Type (delrin/brass) ‘Absolute’ Type

  14. Options for Water Level Measurement Gas Purge Operation

  15. Gas Purge (Open) System ‘Bubbler’ Basic Operating Principle • dry nitrogen (or air) bubbled into the stream via a small diameter tube • bubbles escape from the end of the tube (orifice) • pressure transducer monitors changes in pressure within the tubing • available as ‘single’ or ‘dual’ orifice/riverline options System pressure is proportional to water level

  16. Pressure Transducers – ‘Dry’

  17. Bubble Unit Operating Principle • Uses ‘dry nitrogen’ cylinder • Provides a constant ‘differential’ of 3-5 PSI (21-35 kPa) above the • pressure head at the orifice • Differential maintains a constant stream of bubbles at the orifice • HS23 bubble rate ‘pre-set’ at factory • Eliminates risk of silicon oil entering ‘riverline’ • ‘Quick Connect’ fitting available for check of bubble rate

  18. Bubble UnitTypical Installation

  19. Compressors • Alternative to gas cylinders (Safety Issues) • Effective air drying system essential - moisture ingress • - aquatic growth • Some limitations – ‘riverline’ length < 200 metres • - maximum head of 30 metres • Low powered types available (12V: 38aH with solar)

  20. Compressors – ‘Bubbler'

  21. Gas Purge (Open) System‘Bubbler’ Single Orifice / Single Line

  22. Gas Purge (Open) System‘Bubbler’ Single Orifice / Dual Line

  23. Gas Purge (Open) System ‘Bubbler’ Dual Orifice

  24. Old Style (Closed) Gas System

  25. ‘Hydrostatic’ (Closed) Gas System

  26. Compressors – ‘Hydrostatic’

  27. Ultrasonic Systems • Ultrasonic pulses emitted by the transducer • Pulses are reflected by the water surface and reflected back to the transducer • Time from emission to receipt of the signals is proportional to the level in the vessel • Mounted vertically above stream

  28. Doppler Systems • If the distance between the transducer and the reflecting object is decreasing, frequency increases • If the distance between the transducer and the reflecting object is increasing, frequency decreases • Water level measured by ‘vertical’ acoustic beam • Systems also capable of flow measurement

  29. Radar Systems • Extremely short microwave impulses are emitted by the antennae system to the water surface • These impulses are reflected by the water surface and received again by the antenna system • Time from emission to reception of the signals is proportional to water level in the stream

  30. Laser Systems • Changes in water level based characterised by intensities of angular reflectance of light

  31. Comparison of Methods