1 / 15

SA2001 2 Ch High Voltage Module

SA2001 2 Ch High Voltage Module. Main Features for each channel: V out = 12 kV I out = 1 mA R ipple = < 200 mVpp. SA2002 2 Ch Low Voltage Module. Main Features for each channel: V out = 4.5 ÷ 5.5 V 6.5 ÷ 7.5 V I out = 2 A 1 A R ipple = < 20 mVpp. SA2003 4 ch DAC Module.

ebony
Download Presentation

SA2001 2 Ch High Voltage Module

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SA2001 2 Ch High Voltage Module Main Features for each channel: • V out = 12 kV • I out = 1 mA • Ripple = < 200 mVpp

  2. SA2002 2 Ch Low Voltage Module Main Features for each channel: • V out = 4.5 ÷ 5.5 V 6.5 ÷ 7.5 V • I out = 2 A 1 A • Ripple = < 20 mVpp

  3. SA20034 ch DAC Module Main Features for each channel: • 14 bit progammable voltage = 0 ÷ 3 V • I out = 20 mA

  4. SA20041 ch Low Voltage High Current Module Main Features for each channel: • V out = 4 ÷ 6 V • I out = 60 A • Ripple = < 50 mVpp

  5. SY1527 SystemOverview • Wide range of HV & LV modules for all detectors • Easy interfacing for DCS integration • Magnetic field and rad-tolerant units • High reliability and long-run full support SY1527

  6. Terminal Front-End Command Front-End SY1527Interactive Interfaces Telnet Client ANSI Terminal Front panel TCP/IP RS232 Local SY1527

  7. OPC Client Custom Applications Lab-View OPC Server Std Drivers & Libraries SY1527 Command Interface TCP/IP SY1527 Terminal Front-End Command Front-End

  8. Summary • SASY: a Sub Assembly SYstem • Functional Prototype for Easy Testing • Parameters controlled via SY1527 mainframe • SY1527 can be easily integrated within DCS via OPC control

  9. TEST SETUPSA2001SA2002SA2003

  10. SA2002 SA2003 SA2001

  11. SASY Address Communications Sig48V Pwr48V Bypass Fuse Earth

  12. SY2527 . 48V sig. Communications

  13. SY2527’s monitor The monitored values did not change remarkably during the tests

  14. Instruments: -n°1 Branch controller -n°1 Load board SA2001 -n°1 Load board SA2002 -n°1 Load board SA2003 -n°1 Oscilloscope TEKTRONIX YHS720P -n°1 SASY -n°1 System SY2527 -n°1 Tester Goldstar DM-332

  15. Waveform0-7KGauss

More Related