1 / 63

Smart Metering Development

Tczew, XI 2012 r. Smart Metering Development. Smart Metering Development. Continued cooperation with Flonidan A/S in development of GxS line meters UniSmart : Telemetry Module Automatic Meter Reading Walk-by and Drive-by systems Stationary systems

eden
Download Presentation

Smart Metering Development

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tczew, XI 2012 r. Smart Metering Development

  2. Smart Metering Development • ContinuedcooperationwithFlonidan A/S in development of GxSlinemeters • UniSmart: Telemetry Module • Automatic Meter Reading • Walk-by and Drive-by systems • Stationary systems • Smart Components Development • Shut-OffballValvewithstepper motor • New Cable Transfer • Modular design of New Metrix EU • New Fields for Cooperation • SecureMeters Ltd. • GWi • Metrixemployeearemembers of: • OMS workgroup • prEN16314 AdditionalFunctionalities WG

  3. GxS Smart Gas Meters • New Smart Meters GxS series combine all the best features and capabilities of previous models : • Reliable, resistant to interference, optical pulse readings from measuring unit, using a Gray code wheel • Much bettermetrologicalaccuracydue to error curvecorrection • Temperaturecompensation • Internalshutt-offvalve • Volume and Alarmsregistarion • Remote safereadingusing AES-128 encryption • Wired/Wireless communication EN-13757 NTA8130 + DSMR v.2.2/2.3/3.0

  4. Compact design • MID Class 1,5 • ATEX II 1/2 G Ex ia/ib IIB T3 • IP-54 • Over15 battery life time

  5. Temperaturecompensation Electronic Unithas theabilityto compensate for the effect of temperature on the measurement error. Temperature correction is performed in a volume of 4 points: -25, 0, +30, +55 C. Between these points, linear interpolation is used Temperaturesensors

  6. Curve error correction • Much bettermeasurmentaccuracy • errorsbelow limit ± 0,3% !!!

  7. Evolutioninstead of Revolution From magneticcoupling… … to opticalGray codereading

  8. Gray codewheel… • Realiablepulsereadingmethoduse3 opticalsensors, allowing to measurewithressolution of 1/8 rotation of measuring unit cyclicvolume. • Opticalpulsereadingistamper proof againstmagneticfields phototransistors

  9. Gray codewheel… 1 2 3

  10. Gray codewheel… 1 2 3

  11. Gray codewheel… 1 2 3

  12. Gray codewheel… 1 2 3

  13. Gray codewheel… 1 2 3

  14. Gray codewheel… 1 2 3

  15. Gray codewheel… 1 2 3

  16. Gray codewheel… 1 2 3

  17. New Cable Transfer • The seals are capable of remaining hermetic after exposure to 820°C • The leakage rate of the seal after exposure to 820°C would be better than 1x10-6 cc per sec of helium.

  18. GSU shutt-off valve • Safe, internal, build-innewgeneration of ballvalve: • Safe open function • Lowpressure drop in comparison to competitivedesigns • Two state valvepositioncontrol (fullyclosed / fullyopen), confirmed by realiablemicroswitchdesigned to workin gas and oil enviroment • Installation on the gas meteroutlet(less contamination) • HigherIntrinsicallySafty - usingindustriy field provenstepper motor manufactured by Johnson Electric Group ®

  19. up to (Qmax@G10) Pressure drop

  20. Two state positioncontrol Microswitch

  21. Modular design: UG-NL220 mm adapter

  22. Modular design: UG-EN6” (152,4 mm)

  23. Modular design: UG-F130 mm

  24. Flexibility • Comaptible with all UG meters • 1,2 dm3 • 2,2 dm3

  25. Design challenges Design optimalizationusing CFD Computional Fluid Dynamics

  26. CFD simulations Pressure dropacc. CFD ~0,2 mbar Real pressure drop ~0,15 mbar Othermodels <0,05 mbar

  27. CFD optimized adapter of: UG-F110 mm

  28. UG-NL 220 mm

  29. UG-NL 220 mm

  30. UG-NL 220 mm

  31. UG-NL 220 mm

  32. UG-F 130 mm

  33. UG-F 130 mm

  34. UG-F 130 mm

  35. UG-F 130 mm

  36. UniSmart: telemetry module • Communication • Pulsecounting • 1 pulse = 1 fullrotation of lastcounterroller(for metersG1,6 - G6 1 puls=10dm3, for meters G10 1 ipuls=100dm3) • Algorithm of errorseliminationsuch as errorsdue to mechanicalvibration of rollers in counter.

  37. UniSmart: Functionality • The conversion of the volume pulse(m3); • Flowshistory (60-dayly, 120-monthly); • Alarm registers: • Interference by an external magnetic field; • Exceeding the maximum flow(Qmax); • Lack of pulse. • Bootloader (possibility of remote firmware upgrade) under developmentDatagramEncryptionAES-128 acc EN13757-3: • OMS (with dynamicinitializationvector); • NTA (with dynamicinitializationvector); possible development • NTA (withstaticinitializationvector).possible development • Power supply: 1x lithiumbatterytype AA; • BatteryOperation10 years

  38. AMR (ang. automatic meter reading) Remote reading system • Walk-by system Stationary system

  39. Walk-by system

  40. Inkasent PDA application

  41. PSION Terminal • Mobile terminal PSION WORKABOUT PRO

  42. Stationary system

  43. Data Concentrator (MUC) under development • File generating *.csv • GSM hubs can supply with solar panels

  44. Data Concentrator (MUC) under development • GSM Hubs: • Power supply 230 V AC • Solar panelspowersupplies

  45. M-BUS retransmitter under development • Retransmitters • Power supply 230 V AC • Baterrysupply

  46. Pilot Instalationin: Wielkopolskiej Spółka Gazownictwa S.A.

  47. Pilot Instalationin WSG S.A. • GxSSmart Metershasbeenusedinthe pilot with OMS protocolcommunication. • Metersconfigurationincludes: • Errorcurvecorrection (Vc) • BaseVolumeconversion (Vb)

  48. AdditionalFunctionalitiesImplementedduring pilot instalation • Solutionfrom Smart Gas MetersidewhichallowsCustomer to balancingthe gas network system. • Interopability: Overall system hasbeenintegreated to fit both for existingaplication systems and atdeviceleveltoo. • We havebeengreatfull to receiveinterestfrom National Notified Body of Oil and Gas (INiG). CooperationwithINiGcanenhance an ongoing Project

  49. More then 2000 GxS Smart Gas Meters Drive-byreading by PSION WORKABOUT PRO 3 and car roofantenas