1 / 42

Principes techniques

coloscanner. GHIF 2008. Principes techniques. Dr Vincent Barrau, Pr. Robert Benamouzig Centre Cardiologique du Nord Hopital Avicenne. vincent.barrau@bjn.aphp.fr. Explorations radiologiques du colon. Lavement baryté Coloscanner à l’eau Coloscanner à l’air. Place du radiologue parlant

evadne
Download Presentation

Principes techniques

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. coloscanner GHIF 2008 • Principes techniques Dr Vincent Barrau, Pr. Robert Benamouzig Centre Cardiologique du Nord Hopital Avicenne vincent.barrau@bjn.aphp.fr

  2. Explorations radiologiques du colon • Lavement baryté • Coloscanner à l’eau • Coloscanner à l’air

  3. Place du radiologue parlant du coloscanner ???

  4. AJR 2008 Feb; 190(2):374-85 Place et intérêt du lavement baryté à réserver aux opacifications post opératoire... quoique....

  5. Place du Coloscanner à l’eau Coloscanner à l’eau = TDM abdominal avec remplissage du colon avec de l’eau préparation minimale (avantage de la technique)++ interprétation simple, injection de contraste obligatoire • Cancer du caecum

  6. place du coloscanner à l’eau Coloscanner à l’eau ! Patient âgé symptomatique exploration colon +viscères Coloscanner à l’air Patient asymptomatique dépistage polype cancer

  7. Coloscanner à l’air= “Coloscopie virtuelle”Principes techniques • Etape 1 : préparation colique • Etape 2 : distension colique • Etape 3 : interprétation

  8. Etape 1 : préparation colique • Consensus(1) sur l’association: • Régime sans résidu 2 à 3 jours avant • Agent laxatif • Marquage des selles (1) Consensus on current clinical practice of virtual colonoscopy; AJR 184; march 2005

  9. Préparation : agent laxatif, lequel ? • PEG vs Sodium Phosphate Radiology 2001;218:274-277 Résidus liquidiens significativement (p<.001) moins important avec le sodium phosphate (CI si insuffisance rénale ou cardiaque)

  10. Marquage des selles, pourquoi ? • En scanner, sans injection • densité polypes - tumeur = gris = densité liquides Liquides marqués par de l’iode Liquides Polype

  11. Préparation : marquage des selles, pourquoi ? Polype gris sur gris, difficile à voir ! Blanc sur gris ,c’est plus facile à voir !

  12. Tumeur Même densité liquide et polypes Liquides

  13. Tumeur ???

  14. marquage des selles : améliore spécificité petites lésions Polype Selles marquées

  15. photo résidu stercoral pseudo polype

  16. Préparation : direction prepless? • Pourquoi prepless ? • Gluecker and et al (1) : Préparation colique partie la plus contraignante de l’examen pour les patients • Techniquement possible grâce au marquage des selles • (1) Glucker et al. : Patient acceptance for CT colonography: what is the real issue? et al., European radiology ;june 2002;1410-5)

  17. marquage des selles, régime sans résidu, bisacodyl 168 patients, 73 polypes Radiology vol 247; 122-132 Iannaccone R et al., Gastroenterology 2004 127; 1300-1311, CT colonography without cathartic preparation for the detction of colorectal polyps. • polypes> 8mm • sensibilité : 95% • spécificité :92%

  18. Prepless, patient 77 ans

  19. Prepless raté Préparation conventionelle

  20. Etape 2 : Distension colique Distension : canule rectale et insufflation manuelle (air) ou automatique (CO2)

  21. Limites de la distension...valvule iléo-caecale continente... et...patient algique

  22. Réalisation de l’examen Basse dose Sans injection de contraste Procubitus / Décubitus

  23. Decubitus dorsal Procubitus

  24. Procubitus Décubitus dorsal

  25. Etape 3 : Interprétation Vue 2D Vue 3D Vue Autodissection

  26. Computer Aided Detection • CAD (1): • - améliore la détection des polypes • - réduit le temps d’interprétation • ne peut pas se substituer à l’analyse • radiologique (1)Halligan et al., CT colonography : assessment of radiologist performance with and without CAD, Gastroenterology 2006;131:1690-1699

  27. C.A.D.

  28. Résultats - Sensibilité - Spécificité Pickhardt, NEJM dec 2003;vol 349; n 23; 1233 patients Rockey, Lancet 2005; 365: 305-11 614 patients Rockey : pas de marquage des selles, pas d’analyse 3D en premier. Aucune des deux études avec CAD

  29. Questions pratiques • durée de l’examen = 10 minutes • durée de l’interprétation = qualité dépendante 10 - 30 min • coût = coût TDM abdominopelvien sans inj: • 61E honoraires + FT variable selon machine (2*59 à 2*100) • complications : • perforations(1) = 0.009% (2/21923) • ballonements, douleurs variable selon patients. • Contre-indications : grossesse, affections aiguë en poussée (diverticulite, Crohn en poussée...) (1) : Pickhardt et al, incidence of colonic perforation at ct colonography: review of existing data and implication for screening asymptomatic adults; radiology 2006; 239: 313-316

  30. Questions pratiques : • Irradiation • Coloscanner à l’air : examen low dose : ≈ 5mSv (20 mois) ≈ lavement baryté 5mSv • irradiation naturelle ≈ 3mSV /an. Voyage avion : 0.03 mSV • TDM abdominal ≈10 mSV • Radio thoracique ≈ 0.1mSV Attention coloscanner basse dose sans injection: exploration insuffisante pour le foie, pancréas etc....

  31. Faux positif : Polypes multiples ?

  32. Faux négatifs Ct colonography : False negative interpretations; doshi and radiology; vol 244; number 1; july 2007 114 polyps FN , lecture 2D, pas de marquage des selles,pas de CAD

  33. Même patient coloscannerpolype villeux de 5cm !!! • sa Sans distension, lésion non visible Avec distension tumeur de 5 cm

  34. Polype villeux de 5 cm

  35. Faux négatifs Lésions planes

  36. Coloscanner, une aide à la coloscopie coloscopie incomplète mégadolichocolon...

  37. Détecter une tumeur synchrone en cas de coloscopie incomplète

  38. Mieux localiser une tumeur en pré-opératoire Localisation pré-opératoire double cancer du colon transverse

  39. Planification du traitement des lésions multiples

  40. Le futur .... • Logiciel cleansing • Vidéocapsule • Imagerie fonctionelle (pet scan - irm diffusion)

  41. Messages à retenir • 1-Plus de lavement baryté si coloscanner disponible • 2-Coloscanner à l’eau =pas examen de dépistage, patient symptomatique • 3-Préparation coloscanner différente de celle de la coloscopie (marquage des selles) • 4-Possibilité de prepless pour les récalcitrants • 5- Qualité de l’examen : Préparation/distension/interprétation dépendante.

More Related