Asia IRCAD MIS Trainning Center Planning. █ Experimental Lab Spatial Relation Diagram. Servics. Main. Public. Changing Room (Male). Office (Cafe). Changing Room (Staff). Trainee. Changing Room (Female). Storage (emg.). Storage (Routine). Experimental Lab (18 tables). Pack.

joshwa
Download Presentation

Changing Room (Male)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Asia IRCAD MIS Trainning Center Planning █Experimental Lab Spatial Relation Diagram Servics Main Public Changing Room (Male) Office (Cafe) Changing Room (Staff) Trainee Changing Room (Female) Storage (emg.) Storage (Routine) Experimental Lab (18 tables) Pack Clean Visit V.I.P (2 tables) Guest Trash Route Animal Room (Independent) T. C. T. Architrctural Resources

  2. Asia IRCAD MIS Trainning Center Planning █Site Plan T. C. T. Architrctural Resources

  3. Asia IRCAD MIS Trainning Center Planning █Site Plan T. C. T. Architrctural Resources

  4. Asia IRCAD MIS Trainning Center Planning █1st Floor Plan T. C. T. Architrctural Resources

  5. Asia IRCAD MIS Trainning Center Planning █2nd Floor Plan T. C. T. Architrctural Resources

  6. Asia IRCAD MIS Trainning Center Planning █3rd Floor Plan T. C. T. Architrctural Resources

  7. Asia IRCAD MIS Trainning Center Planning █Main arrangement in the revised Asia IRCAD design General ‧Construction Specific highlight ‧ Auditorium ‧Experimental Labs ‧Changing Room 3 Floors housing all IRCAD training related facilities - Admin. Office, Animals rooms, AV offices, Supply storage rooms... etc. 1 auditorium with 120 seating capacity - larger table for writing notes clearance between two chairs will be increased by 5cm One lab with 20 operation table in which 2 tables are positioned in a VIP room - space between the table will be increase by 50 cm Separate rooms between guest and staff. Room size for guest will be larger with flexibility to quickly change portions of space from Female to Male usage or vice T. C. T. Architrctural Resources

  8. Asia IRCAD MIS Trainning Center Planning █Main arrangement in the revised Asia IRCAD design 2 rooms 4 small rooms with capacity of 8 seats and 1 larger room with a capacity of 18 seats. 5 temp. offices for visiting Lecturers/experts ‧Allowance for future expansion ‧Experimental labs should have a centralized gas system ‧Hanging surgical light + apparatus weights about 350 kg per unit. ‧Space should be allocated for surgical instrutment table + Life support apparatus to move around op table and staff to pass by with cart etc. ‧Allow for vistors to view the op room from outside. ‧OR room for robotic surgery ‧Meeting rooms ‧Temp. offices Special Considerations T. C. T. Architrctural Resources