Static Proof Test @ HYTEC Bottom Tray -002

Static Proof Test @ HYTEC Bottom Tray -002. July 23 & 24, 2003. Pre-Test of Vertical Fixture. Performed vertical fixture load test/calibration checks prior to 1 st test of bottom tray Verify fixture design & accuracy of load application. Test Article: Bottom Tray -002.

kamil
Download Presentation

Static Proof Test @ HYTEC Bottom Tray -002

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Static Proof Test @ HYTECBottom Tray -002 July 23 & 24, 2003

  2. Pre-Test of Vertical Fixture • Performed vertical fixture load test/calibration checks prior to 1st test of bottom tray • Verify fixture design & accuracy of load application

  3. Test Article: Bottom Tray -002 Thermal/Mechanical Sidewalls Tower Simulator Tray #2 (from prototype tower) Bottom Tray (-002)

  4. Instrumentation Load Cell (7500 lb Max) LVDT Displacement Probes (12 Channels) Strain Gages (20 Channels)

  5. Vertical Axis Static Proof Test • Test Load: 12,760 N (40 g’s) • Test performed to 100% of 3 Static Equivalent Random Vibration Loads in tension • Compression not performed due to time constraint • Max Predicted Flexure Loads • Corner Flexure • Axial = ±2422N • Shear = ±93N • Side Flexure • Axial = ±829N • Shear = ±26N • Results: NO Evidence of Damage – Test Successful

  6. Vertical: Measured Compliance

  7. Test Load: 8600 N (27 g’s) Test performed to 100% of 3 Static Equivalent Random Vibration Loads Both directions were tested (positive & negative) Y-axis loads are more sever than X-axis Max Predicted Flexure Loads Corner Flexure Axial = ±3898N Shear = ±850N Side Flexure Axial = ±1716N Shear = ±3104N Results: NO Evidence of Damage – Test Successful Lateral Y Static Proof Test

  8. Lateral Y: Measured Compliance

  9. Lateral XY (45 Axis) Static Proof Test • Test Load: 9550 N (27 g’s) • Test performed to 100% of 3 Static Equivalent Random Vibration Loads • Both directions were tested (positive & negative) • Corner Flexure buckling critical load case • Max Predicted Flexure Loads • Corner Flexure • Axial = ±6224N • Shear = ±1473N • Side Flexure • Axial = ±1347N • Shear = ±2440N • Results: NO Evidence of Damage – Test Successful

  10. Lateral XY: Measured Compliance

  11. Lateral XY: Peak Sidewall Strains