1 / 10

HES HKS meeting

HES HKS meeting. 21/Apr/2011 T.Gogami. Contents. Stricter TDC cut of KTOF Improvement Analysis time Number of Kaon Check for all targets . DC hit info. selection with TOF. Gravity. CUT. Particle direction. ~17%. Selective region. Maximum gradient. ~8%. CUT. Minimum gradient.

kenda
Download Presentation

HES HKS meeting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HES HKS meeting 21/Apr/2011 T.Gogami

  2. Contents • Stricter TDC cut of KTOF • Improvement • Analysis time • Number of Kaon • Check for all targets

  3. DC hit info. selection with TOF Gravity CUT Particle direction ~17% Selective region Maximum gradient ~8% CUT Minimum gradient Procedure in “h_dc_tofcut.f” Get KTOF1X & 2X hit counter information Make combination of 1X and 2X hit counter if those two are in same group (grouping) Determine cut conditions on KDC1 & KDC2 Select Hit wires in KDC and Reorder them

  4. Check works of the code KDC1 KDC2 v v’ v v’ uu’ uu’ • GREEN regionSelective region • RED markers & linesSelected hit wires • BLACK markers & lines Rejected hit wires particle particle x x’ x x’

  5. KTOF TDC • Cut 10000 – 50000 (Current) 18000 – 20500 (New) Run 76314 for CH2 target Run 77124 for 52Cr target

  6. Multiplicity improvement history Multiplicities just before tracking stage Original DC hit selection wit TOFs Stricter TDC cut of TOFs

  7. Multiplicity improvement history Applied TDC cut Multiplicity went down ! • Analysis time • 20% reduction for 52Cr • Number of Kaon (RUN:77124, 52Cr) • 56  70  90  130 DC TOF cut Matrix DC TOF cut ‘ (TDC cut)

  8. Checked KTOF TDC of all targets • Modified parameter files • e05115replay/PARAM/ • hhodo.param.75884 • hhodo.param.75886 • hhodo.param.75921 • hhodo.param.76092 • hhodo.param.76118 • hhodo.param.76376 • hhodo.param.76646 Correct coincidence window

  9. Summary and to do • Summary • Stricter TDC cut of KTOFs • Stricter KDC hit wires selection • Analysis time : 20% reduction for 52Cr • Number of Kaon : 2 times more compared to rev.456 • Checked for all targets • To do • Λ’s Cross section check for CH2 and H2O targets • If consistent result shows up • Matrix • E05-115 • E01-011 • Tracking • Parameter optimization • Residual • Documents • RA • 授業料免除 • 学振 • Germany • Departure date : 6/May/2011

  10. End 17/Apr/2011

More Related