Benchtop Dissolved oxygen meter

<br>Benchtop Dissolved oxygen meter is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure <br>compensation helps in accurate measurement of dissolved oxygen. The system menu of dissolved oxygen meter can set 6 parameters which includes the number <br>of calibration points, temperature units etc.<br>

kibmer
Download Presentation

Benchtop Dissolved oxygen meter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Personalized PDF Catalog Catalog Generated On : 07/12/2023 Benchtop Dissolved oxygen meter

  2. https://www.labtron.info/ info@labtron.info | Description : Benchtop Dissolved oxygen meter is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. The system menu of dissolved oxygen meter can set 6 parameters which includes the number of calibration points, temperature units etc. Specifications :

  3. Dissolved 0.0 to 20.0 mg / L (or oxygen range ppm) Dissolved ± 0.5 mg / L oxygen accuracy Resolution 0.1 mg / L Calibration 1 - 2 points points Polarographic DO Sensor type probe

  4. Temperature 0 to 40 °C, 32 to 104 compensation °F range Barometric 60.0 to 112.5 kPa, pressure 450 to 850 mmHg correction Salinity 0 - 35 g / L correction % of saturation 0.0 to 200.0 % of oxygen range

  5. % of saturation of oxygen ± 10 % F.S. accuracy % of saturation of oxygen 0.001 resolution Allows setting of 6 System menu parameters Manual or Data hold automatic endpoint function detection

  6. Manual or Power off automatic (180 minutes) Reset function Yes Backlit LCD (135 × Display 75 mm) Connector 6 pin mini plug DC 9 V, use of SC Power adapter, AC 220 V / 50 Hz

  7. Dimension (L × 210 × 205 × 75 mm W × H) Weight 1.5 kg Features : Equipped with polarographic sensor Equipped with large backlit LCD display

  8. 1-2 points calibration using air saturated water & zero oxygen solution Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen

  9. System menu allows setting the 6 optional parameters Automatic temperature compensation for accurate measured value over the entire range Auto hold function freezes stable, final readings for

  10. better viewing and recording Reset function automatically resumes all the settings to default mode Help message as an operational guide for quick beginning to the dissolved oxygen meter

  11. Applications : Benchtop dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

  12. www.labtron.info Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom