Time Alignment For Real Time Measurement

Time Alignment For Real Time Measurement. Time Alignment. Time Alignment is an important factor in the calculation of mass emissions from vehicles operating under transient conditions from raw exhaust measurements Key parameters include :- speed of response of the exhaust flow measurement

mharden
Download Presentation

Time Alignment For Real Time Measurement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Time Alignment For Real Time Measurement

  2. Time Alignment • Time Alignment is an important factor in the calculation of mass emissions from vehicles operating under transient conditions from raw exhaust measurements • Key parameters include :- • speed of response of the exhaust flow measurement • speed of response of the exhaust analysers • corrections for water content differences between exhaust flow rate and measured concentrations (exhaust flow is usually wet base, analysers can be wet or dry base) • Analyser interferences can be an issue • Ambient corrections to be considered (Nox correction, altitude)

  3. HORIBA study on time alignment EXSA-240 flow configuration Response Time EXSA-240 Nox/O2 analyserSpeed of response

  4. Nox is the main issue (EPA-505)

  5. Other gases are not so sensitive - CO2

  6. CO

  7. HC - NDIR

  8. OBS Time Alignment • OBS has freely adjustable time delays. Current setting is Td + T50 • A check utility will be included to measure TdT50 and T90 in the future software for the OBS-2000 series

  9. OBS Mass Calculations

  10. Standard Mass Calculation • Mass Emissions Mass = Exhaust_Flow * Concentration * DensityWhere Exhaust flow = litres @20 deg C / 101.3 kPaConcentration = ppm/10e6Density = standard densities (CFR) in g/litre @20 deg C/101.3 kPa • Mass is calculated in 10 Hz basis and integrated • OBS-1000 does NOT correct the Nox mass for the Nox engine air humidity (Nox correction factor)