1 / 13

Summary from MET DQM Plot Scanning

Summary from MET DQM Plot Scanning. MET DQM Plots. From CRAFT data. https://cmsweb.cern.ch/dqm/tier-0/. JetMET POG DQM is already routinely run. Run 66594. With HF. Lumi Section. Number of events. Barrel+Endcap Only. Lumi Section. Number of events. METPhi (rad). MEx (GeV). MEy (GeV).

nikita
Download Presentation

Summary from MET DQM Plot Scanning

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Summary from MET DQM Plot Scanning METDQM Study

  2. MET DQM Plots From CRAFT data https://cmsweb.cern.ch/dqm/tier-0/ JetMET POG DQM is already routinely run METDQM Study

  3. Run 66594 With HF Lumi Section Number of events Barrel+Endcap Only Lumi Section Number of events METPhi (rad) MEx (GeV) MEy (GeV) First few lumi sections appear to be problematic. METDQM Study

  4. Zoom-in view Problem only in a first few lumi sections On a lumi section based method, can keep the majority of events Run 66594 cont’d METDQM Study

  5. Data certification Looking at Chi2 of double Gaussian fits: reduced chi2 <20 (lum section) or 200 (entire run) (Need to adjust the criteria based on the statistics) Mean of the fitted Gaussian form: within +-10 GeV Run 66594 cont’d METDQM Study

  6. Run 66714 With HF Lumi Section Number of events Barrel+Endcap Only Lumi Section Number of events MEy (GeV) METPhi (rad) MEx (GeV) No major problem. METDQM Study

  7. Run 66714 cont’d • Data certification output Good run METDQM Study

  8. Run 66746 With HF Lumi Section Noise in HF at phi~0.8 Number of events Barrel+Endcap Only Lumi Section Number of events METPhi (rad) MEx (GeV) MEy (GeV) Check of the mean MEx or MEy will detecot this problem. METDQM Study

  9. Run 66746 cont’d • Data certification output MET without HF mostly OK METDQM Study

  10. Run 67124 With HF Lumi Section Number of events Barrel+Endcap Only Lumi Section Number of events METPhi (rad) MEx (GeV) MEy (GeV) met with/withtou HF seem to suffer from hot tower(s) METDQM Study

  11. Run 67124 cont’d • Data certification outputs Bad Run METDQM Study

  12. Run 68021 With HF Lumi Section Number of events Barrel+Endcap Only Lumi Section Number of events METPhi (rad) MEx (GeV) MEy (GeV) No major problem. METDQM Study

  13. Run 68021 cont’d • Data certification outputs METDQM Study