1 / 40

Diagnosis of Work-related Asthma

Diagnosis of Work-related Asthma. Professor, Dept Medicine, and Dalla Lana School of Public Health University of Toronto, Respiratory Division, Toronto Western Hospital. Susan M Tarlo, MB BS, FRCP(C). Chest 2008. These groupings are not mutually exclusive; e.g. OA can be followed by WEA.

ophira
Download Presentation

Diagnosis of Work-related Asthma

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Diagnosis of Work-related Asthma Professor, Dept Medicine, and Dalla Lana School of Public Health University of Toronto, Respiratory Division, Toronto Western Hospital Susan M Tarlo, MB BS, FRCP(C)

  2. Chest 2008 These groupings are not mutually exclusive; e.g. OA can be followed by WEA

  3. Guidelines and Statements • Assessment of Asthma in the Workplace, an ACCP Consensus Statement. Chest 1995;108:1084-117. • CTS Guidelines on Occupational Asthma. Can Resp J 1998;5:289-300 • British Thoracic Society, Standards of Care for Occupational Asthma. Thorax 2008;63:240-50. • Diagnosis and Management of Work-related Asthma. ACCP Consensus Statement. Chest 2008;134:1S-41S.

  4. Consensus Document Diagnosis and Management of Work-related Asthma. ACCP Consensus Statement. Chest 2008;134:1S-41S. http:/www.chestjournal.org/cgi/content/abstract/134/3_suppl/1S   - Based on an AHRQ evidence-based review, (Agency for Healthcare Quality and Research) 2005, supplemented by recent literature review to Dec 2006 and by panel consensus

  5. WEA • Work-related worsening of asthma that started before the job or began incidentally. • Common (up to 25% of working asthmatics) • May be transient and diagnosed on history or may occur daily at work and may mimic occupational asthma, requiring similar investigations • May be due to expected asthma triggers such as dusts or temperature extremes, or to common allergens that may be in the workplace.

  6. OA • OA= Asthma due to causes and conditions which are attributable to a particular workplace environment and not to stimuli encountered outside the workplace: • Irritant-induced • Sensitizer-induced

  7. OA? • Some WRA does not clearly fit the definitions – previous childhood asthma recurring from sensitization to a specific work agent - existing asthma that worsens at work from sensitization to a specific work agent • Clinical implications of these are as for OA but may/may not be included in compensation definitions

  8. Differential diagnosis for WRA • Other asthma (non-occ) coincidentally worse while working • Non-asthma causes for asthma-like symptoms • GERD • Upper airway cough syndrome (post nasal drip) • Irritable larynx syndromes (WILS) – Hoy et al Occupational Medicine 2010; 60:546-51[30 cases vs 90 WRA] • Hyperventilation/anxiety • Eosinophilic bronchitis • - or any combination of these ± WRA

  9. OA - Irritant-induced (Reactive Airways Dysfunction Syndrome) • About 7% of all OA: from a high irritant exposure • Onset typically within 24 h of exposure • New symptoms of asthma, persist >3mo • Exposure expected to be a high level irritant • Asthma confirmed: PFTs / methacholine responses • documented absence of previous respiratory disease • No specific diagnostic test available • Most certain = RADS, less certain if criteria not all met

  10. Sensitizer-induced OA DiagnosisValue of the history • Exposures, symptoms: start while working, improve w-ends/holidays off work PPV 63%, NPV 83% (Malo et al ’91) • Daily wheeze worse at work most sensitive (88%) • + itchy nose/eyes • + lack of hoarseness, - predicted 74% of high MWt OA(Vandenplas et al ERJ ’05) Nevertheless overall ~50% of specific challenges are negative even when OA suspected, emphasizing need for objective tests.

  11. Exposure history for sensitizer-induced OA • HMWt almost any airborne protein (plant, animal, fish, fungal, insect, enzymes) • LMWt many reactive chemicals, especially with double bonds and 2 or more reactive side chains Seed M, Agius R. Further validation of computer-based prediction of chemical asthma hazard. Occup Med (Lond) 2010; 60:115-20.

  12. Exposure assessment • Patient’s history: often limited • MSDS, WHIMIS: have limitations, incomplete information • Occupational hygienist assessment: company hygienist, independent private assessment or public health/government agency, e.g MOL, NIOSH

  13. Why objective tests are necessary to diagnose OA • History could be influenced by other factors • Management differs for OA vs. WEA • Early correct diagnosis of sensitizer-OA with removal from exposure leads to the best asthma prognosis • Objective diagnosis may lead to changes to prevent sensitization and OA in other workers

  14. Diagnostic recommendations(from ACCP Consensus 2008) • In patients with a hx of possible OA: • Confirm a diagnosis of asthma objectively • Review MSDS • Skin test where feasible • PEFR and Methacholine responses work and off work, considering possible confounding factors • Add induced sputum if available • Consider specific challenges if available, especially if the diagnosis is in doubt

  15. Objective diagnosis of asthma • FEV1 pre/post bronchodilator • Methacholine/histamine challenge • sensitive for asthma if patient is still working and symptomatic • positive findings do not confirm a work relationship • negative findings do not exclude OA if not recently exposure to the sensitizer • occasional reports of normal responsiveness in diisocyanate-OA

  16. Skin tests/ immunologic tests • Limited skin test extracts commercially available for occupational allergens • Few are standardized • Immunologic sensitization is more common than OA in exposed workers • Skin tests are unhelpful for most low-molecular-weight sensitizers

  17. In-vitro immunologic tests • In-vitro immunologic tests only reliable in a few centres. • Generally less diagnostic value than skin tests for high molecular weight sensitizers, eg natural rubber latex • Limited sensitivity/specificity for low molecular-weight sensitizers at present, eg diisocyanates

  18. Evidence-based medicine Diagnosis and Management of OA (AHRQ ’05)

  19. Beach J et al Chest 2007

  20. Beach J et al Chest 2007

  21. Objective documentation of work-related changes in asthma • Serial peak expiratory peak flow monitoring (PEF) with sx and med diary • at least 4x per day, several weeks at work and off work • requires careful patient instruction • needs compliance • effort-dependent • no generally accepted objective criteria for interpretation • by themselves, positive results do not distinguish OA from work-exacerbated asthma

  22. A 42 year old polyurethane foam worker PEFR (L/min), 4 x per day Working weeks Off work days Methacholine PC20 0.07mg/ml Methacholine PC20 11.6 mg/ml

  23. A 50 year old dry cleaner PEFR (L/min), 4 x per day Working weeks Off work days Methacholine PC20 0.03 mg/ml Methacholine PC20 0.02 mg/ml

  24. PEFs • Also record symptoms and prn medication use. • Keep regular meds stable at the lowest dose to adequately control symptoms but not to mask PEF changes • Record at least 2 weeks at work and 10 days off work

  25. PEF interpretation confounders • Inadequate technique • Poor compliance with recordings • Fabrication of results • Intercurrent cold or non-occupational exposure to asthma triggers • Work exposures not representative of those causing symptoms • Changes masked by medications Any of these may need further repeat PEFS

  26. PEF Interpretation • Expert visual interpretation • Formula e.g. ≥20% variability from maximum occurring relatively more frequently working days vs off work (93% sens 77% specificity when variability >1 day) (Liss, Tarlo ’91) • OASYS: 2-hourly PEFs analyzed to score 1-4, a cut-off 2.5 for OA: 75% sensitivity, 94% specificity (www.occupationalasthma.com) • ABC (area between the curves) uses OASYS2 for curves work days vs days off work with readings >6 times per day, reported 72% sensitive, 100% specific at ABC 15 L/min/hour (Moore VC et al Chest, 2009; 135: 307- 14)

  27. PEFs • Electronic spirometers allow assessment of compliance but expensive (~$500) • Despite problems with compliance, a recent systematic review showed 61% had interpretable recordings and of those, a pooled sensitivity for OA 82%, specificity 88% (Moore et al Ann Resp Med ’10)

  28. Methacholine challenges • Serial inhalation of increasing concentrations of nebulized methacholine • Spirometry pre- and post- each dose. • Test is stopped with at least a 20% drop in FEV1 • PC20 calculated (lower = more hyper-responsive, cut-off 8mg/ml, borderline 4-16mg/ml) • A ≥3-fold worsening in PC20 at work is significant

  29. Methacholine challenge • A single test is useful to diagnose asthma – with current asthma symptoms/exposures • Paired tests (one at the end of a work week and one after a period off work) is useful to assess work-related changes (e.g. OA) • Confounders: lab technique, intercurrent colds or other non-occupational exposures, insufficient time away from work exposure

  30. Peak flows and methacholine responses

  31. Combinations of tests • A combination of investigations has been advocated in OA guidelines/consensus statements, as far as is feasible. • However, skin tests/immunologic tests often cannot be performed, patients often cannot adequately comply with PEFRs, and methacholine/histamine challenges may require travelling a long distance for the tests. • Despite recommendations, patients may have stopped work before assessment and be unwilling/unable to return on a trial basis

  32. Specific laboratory challenges • Labour-intensive and expensive • Require specialized facilities with exposure-monitoring as well as prolonged response-monitoring • Although referred to as a “gold standard”, there can be false positive and false negative responses • In some countries, medicolegal concerns regarding positive responses have also limited use

  33. Laboratory challenges

  34. Limitations to specific challenge interpretations (? how frequent) • False positive: • irritant exposure levels • uncontrolled asthma or unrelated exacerbation • False negative responses: • wrong “sensitizer” • insufficient exposure (concentration/duration), especially after a prolonged period away from exposure • failure to monitor for late responses or airway responsiveness changes

  35. Workplace challenge • Open challenge in suspected work area compared with an expected unexposed area • Objective monitoring at work (e.g. hourly spirometry, preferably with laboratory quality equipment and personnel) • Expensive, employer may not permit access, exposures not blinded • Most effective for hospital workers who can have the tests on-site in the PFT lab (including methacholine tests)

  36. Induced sputum eosinophilia as a diagnostic test (Girard et al AJRCCM ’04) Induced sputum working and off work (Confounders include inhaled steroid use, URIs and co-incidental allergen exposures)

  37. OA vs WEA Diagnosis

  38. Diagnostic Summary • In patients with a hx of possible OA: • Confirm an objective diagnosis of asthma • Review MSDS / exposures • Skin test where feasible • PEFR and Methacholine responses work and off work, considering possible confounding factors • Consider specific challenges if diagnosis is in doubt • Consider addition of induced sputum if available • A combination of tests is most useful

More Related