1 / 15

KEK Beam Test Results Resistive Foil

KEK Beam Test Results Resistive Foil. Canada, France, Germany, Japan, Philippines KEK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., Japan MSU, Philippines , Carleton Univ.of Ottawa,Univ. de Montréal, Canada ,

ora
Download Presentation

KEK Beam Test Results Resistive Foil

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KEK Beam Test Results Resistive Foil Canada, France, Germany, Japan, Philippines KEK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., Japan MSU, Philippines, Carleton Univ.of Ottawa,Univ. de Montréal, Canada, MPI, Germany, DAPNIA-CEA, Saclay, IN2P3-LAL and IPN, Orsay, France Dan Burke 20/12/05

  2. Outline • Resolution results for ArIso and CO2 • Bias results • Residual vs. X • PRF • Drift Velocity

  3. Resolution σ0 = 104 +/- 3 μm Neff = 41 +/- 12 μm row 7

  4. Resolution – multiple rows together Resolution [mm] Drift Distance [mm]

  5. Resolution σ0 = 87 +/- 3 μm Neff = 30 +/- 5 μm row 7

  6. Resolution – multiple rows together Resolution [mm] Drift Distance [mm]

  7. Resolution Resolution [mm] σ0 = 108 +/- 5 μm Neff = 34 +/- 10 μm Drift Distance [mm] row 7

  8. Resolution – multiple rows together Resolution [mm] Drift Distance [mm]

  9. Bias bias not corrected for

  10. Residual vs. X-track (1T) no large edge effects

  11. Pad Response Function (1T) Amplitude Distance (mm) Not yet fitted for, some difficulties with paw fits

  12. Pad Response Function (1T) Amplitude Distance (mm) Not yet fitted for, some difficulties with paw fits

  13. Drift Velocity

  14. Average amplitude vs. Row # Amplitude 6-9% variation in amplitude for inner rows

  15. Conclusion • Resolution results consistent for ArIso and CO2 • More bias studies • PRF needs to be fitted properly, more time with PAW • Drift velocity calculations accurate and agree with magboltz

More Related