1 / 19

Multi-functional bioresorbable coatings with biofilm inhibition and optimal implant fixation

sereno
Download Presentation

Multi-functional bioresorbable coatings with biofilm inhibition and optimal implant fixation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. 1

    2. 2

    3. 3

    4. 4 Development of innovative, multi-functional bioactive and anti-inflammatory coatings on Ti6Al4V

    5. 5 The project focused on acetabular cups, glenoids and humeral bodies of inverse shoulder implants and dental implants provided by LIMA and HeliPro.

    6. 6 State-of-the-art vacuum plasma sprayed coatings were used as a reference throughout the project. This technique is commercially applied by Alhenia, a leading provider of medical instruments and implants.

    7. 7 An increased surface roughness improves the implant stability, but also increases the risk of biofilm formation. Viable cells (green) tend to spread throughout the porous coating.

    8. 8 A new biomedical grade titanium alloy was developed with advantageous microstructure, excellent biocompatibility, and without aluminium or vanadium!

    9. 9 Electrophoretic deposition (EPD) EPD of particle stabilised emulsions and/or suspensions followed by classical vacuum sintering or vacuum microwave sintering creates a porous Ti mask with an average porosity of 50% and pores ranging from 10-60 µm, improving mechanical interlocking, i.e. biological implant fixation.

    10. 10 Electrophoretic deposition (EPD) EPD of particle stabilised emulsions and/or suspensions followed by classical vacuum sintering or vacuum microwave sintering creates a porous Ti mask with an average porosity of 50% and pores ranging from 10-60 µm, improving mechanical interlocking, i.e. biological implant fixation.

    11. 11 Electrophoretic deposition (EPD) Additional application of bioactive glass enhances the bioactive fixation of the implant

    12. 12 Hydrothermal treatment Provides a bioactive TiO2 layer, which promotes HAp formation, exhibits a photocatalytic effect enabling sterilisation by UV-light and prevents leaching of metal ions into the body.

    13. 13 Micro-arc oxidation (MAO) Creates a titania-based amorphous coating with incorporated calcium phosphates, which acts as a biocompatible top coating for implants with a porous Ti layer for cementless fixation. The highly hydrophylic nature of the coating reduces biofilm formation.

    14. 14 Sol-gel synthesis Sol-gel synthesis of bioactive glass enables coating the internal surface of a porous Ti coating without filling the voids completely (left). As an alternative, the porous structure can be infiltrated with bioactive glass prepared by the particulate sol-gel method (right).

    15. 15 Spraying of anti-microbial coatings An active anti-microbial coating, which releases an antibiotic drug during more than 2 weeks, was sprayed on top to avoid infection and biofilm formation.

    16. 16 Microbial interaction Microbial interaction results in biofilm formation and thus difficult to treat biomaterial-related infections. The influence of various substrate-coating systems on biofilm formation was studied. The importance of the composition and physico-chemical properties of the coating like roughness, porosity, interconnective pore channel size and hydrophobicity were analysed.

    17. 17 Mechanical characterisation of coating-substrates Constant Depth scratch procedure to measure the shear adhesion stress along thick substrate-coating interfaces (> 30 µm). For thin coatings (< 5 µm), AFM was successfully incorporated and combined with a mathematical model correlating the force deformation components.

    18. 18 In vitro and in vivo evaluation In vitro evaluation to investigate the biocompatibility and cell/material interactions of powders and various substrate-coating systems to evaluate the osteogenic potential. A short and long term in vivo study was performed, to evaluate the bone response of porous Ti coatings combined with different bioactive and anti-microbial coatings.

    19. 19 For further information: Visit www.meddelcoat.eu Project coordinator Prof. Dr. Ir. Jef Vleugels Katholieke Universiteit Leuven Department of Metallurgy and Materials Engineering (MTM) Kasteelpark Arenberg 44, B-3001 Heverlee (Belgium) Phone: +32 16 32 12 44 Fax: +32 16 32 19 92 E-mail: jozef.vleugels@mtm.kuleuven.be