CCUM Tests and DCU Calibration

CCUM Tests and DCU Calibration. STATUS REPORT. Setup and Avaibility. Electrical FEC with PMC carrier. CCU/DCU test main board. 2D Barcode Scanner *. FLUKE189 multimeter + T° sensor **. TEC and TIB CCUs. * Pickup from PETAL test setup. ** TOB use IR Thermometer.

sheera
Download Presentation

CCUM Tests and DCU Calibration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CCUM Tests and DCU Calibration STATUS REPORT

  2. Setup and Avaibility • Electrical FEC with PMC carrier • CCU/DCU test main board • 2D Barcode Scanner* • FLUKE189 multimeter + T° sensor ** • TEC and TIB CCUs * Pickup from PETAL test setup ** TOB use IR Thermometer

  3. CCU test and DCU Calibration main board DCU reference CCU Board DCU (to calib) CCUM

  4. ~ 900 CCU-TEC ~ 700 CCU-TIB CCUs avaibility and report • not tested (to be @ Strbg) • ? • Tested @ CERN • Separated in 5 groups @ Strbg • CCU adresses defined (0x3F, 0x5F, 0x6F, 0x77, 0x7B)

  5. CCUM TEC Identification : 2D Codebars • type description barre code • 04 CCU-TEC-F0 302 5200 04 00001 petals F in end cap n° 0 302 5200 04 00200 • 05 CCU-TEC-F1 302 5200 05 00201 petals F in end cap n° 1 302 5200 05 00400 • 06 CCU-TEC-B0 302 5200 06 00401 petals B in end cap n° 0 302 5200 06 00600 • 07 CCU-TEC-B1 302 5200 07 00601 petals B in end cap n° 1 302 5200 07 00800 • 08 CCU-TEC-DOM 302 5200 08 00801 CCU-TEC-DOM 302 5200 08 01000

  6. DCU Calibration : Procedure for TEC/TIB ADC a. Apply Vref_j (J=1..4) to DCU Channel 2 or Channel 3 b. Read DCU Channel 2 or Channel 3 c. Evaluate Gain and Offset (Vin= G * ADCout + D) I20µA a. Read DCU_Channel 0 b. Evaluate I20µA I10µA a. Read DCU_Channel 1 b. Evaluate I10µA Temperature Sensor a. Read DCU_REF_channel 7 b. Read DCU_channel 7 TIME PROCESS ~ 10 min/ CCUM-DCU board

  7. CCU and DCU in DATABASE XML file • Codebare • CCU Address • Tool_Id = 2403 • DCU_Id (_H, _M, _L) • Gain (G in µV/ADC) and Offset (D in µV) • I 20µA and I 10µA • Channel 7 (= DCU Sensor) both DCU • T° (external) both DCU • Offset (D in °C)