1 / 36

CCP4 workshop Argonne, June 2011

CCP4 workshop Argonne, June 2011. Strategy of diffraction data collection (at synchrotrons) Zbigniew Dauter MCL-NCI & ANL-BIO. Advance preparations. 1. Crystals must be prepared 2. You must be prepared because Anything that can go wrong,

taite
Download Presentation

CCP4 workshop Argonne, June 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CCP4 workshop Argonne, June 2011 Strategy of diffraction data collection (at synchrotrons) Zbigniew Dauter MCL-NCI & ANL-BIO

  2. Advance preparations 1. Crystals must be prepared 2. You must be prepared because Anything that can go wrong, will go wrong (Murphy, 2000 BC)

  3. Work at the beam line - Very hectic and/or very boring - Requires quick responses (time is precious) - Full of surprises - technical problems usually on Friday evening… - your best crystals do not diffract - cryo stream develops an ice block - storm in Wisconsin, no power - Rarely fully satisfying, sometimes rewarding (lesson of optimism and perseverance)

  4. Data collection process - Easy to screw-up in many ways - Involves lots of technical problems - But it is science, not technicality - Pays off to “engage your brain” - Last truly experimental step later mostly computing (and writing-up) which may be repeated many times - good quality data make all subsequent steps much easier

  5. Beam line selection - Intensity and brilliance 2nd vs. 3rd generation synchrotron - Collimation, divergence and focusing undulator or bending magnet - Wavelength range - Detector type and size - Crystal characteristics diffraction strength, cell dimensions - Accessibility (APS vs. Spring8) - User friendliness hardware, software and human factor

  6. No marvels But synchrotron beam makes no miracles bad crystal at home will be bad also at the synchrotron “This diffraction is so bad – how good we did not bring our best crystals…”

  7. Type of experiment Always best to have diffraction data complete, high resolution and accurate but of particular importance are: - Native data for refinement highest resolution (multiple passes) - Molecular replacement medium resolution, no overloads - Heavy atom derivative medium resolution, accurate - Anomalous (MAD, SAD) modest resolution (radiation damage) very accurate and complete at low res.

  8. Detector and software In general all CCD or IP detectors and all data processing programs give equally good data (if working properly) Sometimes important is the size of detector front window (e.g. viruses) Some programs are better for particular applications (e.g. d*trek for fine slicing) or more automatic (user friendly) Often experimenter’s experience is more important than data processing program

  9. Quality criteria What means “good data” ? Quantitatively and Qualitatively Complete Accurate All reflections in Intensities have to the asymmetric or be meaningful and the anomalous unit have realistic error have to be measured estimates (sigmas) Very easy, but not good to collect indices without intensities (and their error estimations)

  10. Quantitative completeness of indices Depends entirely on the geometry and mutual disposition of Reciprocal lattice (crystal) and Ewald sphere (radiation)

  11. Ewald construction 3-D illustration of Braggs law: n.l = 2.d.sinq Ewald sphere represents radiation Reciprocal lattice represents crystal

  12. Asymmetric unit in reciprocal space Asymmetric unit in reciprocal space is always a wedge bounded by rotation axes (or planes in Laue group): native anomalous Triclinic – hemisphere - sphere Orthorhombic - octant - quadrant etc. It is important to know where to start and how much to rotate the crystal

  13. Asymmetric unit in 622 – c axis rotation

  14. Asymmetric unit in 622 – a/b axis rotation

  15. Asymmetric unit in 222 – 90o axial

  16. Asymmetric unit in 222 – 90o diagonal

  17. Strategy programs Such considerations are easy with crystals in axial orientation, but in arbitrary orientation it may be difficult Good to rely on the strategy programs (This is a minimalist approach, 360o will always give complete data set, but beware of radiation damage !)

  18. Still image

  19. Increasing rotation Djmax = ___________ - h 180 . d p. a d – resolution a – cell parameter || beam h – mosaicity

  20. Beam divergence & mosaicity in direct space

  21. Beam divergence & mosaicity in reciprocal space

  22. Cell length along the beam Djmax = ___________ - h 180 . d p. a

  23. Overloaded profiles Best, strongest reflections – very important for Fourier maps, Pattersons, direct methods, phasing

  24. Overload extrapolated 65535 = 216-1 standard profile fitted on shoulders and extrapolated above overload value

  25. Missing reflections are never random If missing reflections were spread randomly there would be no serious problem However, for any of the above reasons they are always missing systematically Kevin Cowtan’s duck, back-transformed with missing segment of data:

  26. Intensities (and their uncertainties) Very easy to collect indices without intensities however, intensities should be well measured and accompanied by realistic estimations of their uncertainties (errors, s’s)

  27. Accuracy criteria of intensities Rmerge (Rsym, Rint ) = __________________ I/s(I) - generally > 2, or 50% of reflections > 3s Multiplicity – generally the higher the better Shkl Si |<I> - Ii| ShklSi Ii

  28. Improved versions of Rmerge Rmerge - bad criterion from statistical point of view (depends on multiplicity) Improved forms (unfortunately rarely used): Rmeas = _______________________________ (Diederichs & Karplus, 97) Rp.i.m. = ______________________________(Weiss & Hilgenfeld, 97) Shkl [n/(n-1)]1/2Si |<I> - Ii| ShklSi Ii Shkl [1/(n-1)]1/2Si |<I> - Ii| ShklSi Ii

  29. Criteria of anomalous data Friedel mates can be treated as equivalent in scaling or not, but kept separate on output indicators of anomalous signal: - higher c2 when Friedels merged - higher R merge when Friedels merged - list of outliers

  30. Numerical criteria of anomalous data Ranom = ___________________ ______ = ___________________ _______ = ______________ Shkl |I+ - I-| Shkl |I+ + I-|/2 <DF> Shkl |F+ - F-| <F> Shkl |F+ + F-|/2 <DF> ShklDF <sDF>Shkls(DF)

  31. Rmerge and c2 (Ta6Br12–soaked crystal)

  32. Anomalous data - outliers

  33. Standard uncertainties (s’s) 2-D detectors do not measure individual X-ray quanta but something proportional therefore counting statistics is not valid and s’s must be corrected for detector “gain” t-plot = _________ average = 0.0, s.d. = 1.0 c2 criterion - agreement with expectations <I> - Ii s(I)

  34. Multiplicity More measurements of equivalent reflections lead to more accurate average and s estimation Also scaling and merging is more effective But beware of radiation damage

  35. Radiation damage Typical syndrome of radiation damage – first and last data do not agree with average

  36. Conclusions • X-ray data collection (with 2D detectors) • - scientific process, not technicality • - irreversible consequences (often) • even more important due to progress in • automation, phasing, refinement etc. • Always involves a compromise between • time, redundancy, completeness etc. • - but it should be a wise compromise

More Related