1 / 17

Damage Control II

Damage Control II. Objectives. DC Actions & Reports Classes of Fires & Combating them Firefighting Systems & equipment Flooding systems & equipment. General DC Actions. Rig spaces for casualty Establish primary & secondary boundaries Fight and control casualty with appropriate means

treva
Download Presentation

Damage Control II

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Damage Control II

  2. Objectives • DC Actions & Reports • Classes of Fires & Combating them • Firefighting Systems & equipment • Flooding systems & equipment

  3. General DC Actions • Rig spaces for casualty • Establish primary & secondary boundaries • Fight and control casualty with appropriate means • Localize casualty & stop flooding/extinguish fire • Restore systems to operation • Ventilate the affected spaces if necessary

  4. Flooding & Fire • Must ensure restoration of vital services • Propulsion • Electrical power • Vital piping and machinery • Must always keep safety in mind -> NEVER try to be a one person DC party!!!

  5. Casualty/DC Reports • Initial report • What casualty is & what system • Where casualty is -> be specific • Follow up report • Man in charge • Assistance required • Injured personnel • Damaged equipment • Status of casualty • Keep DC Central informed!!! allows for proper organization of damage control efforts “MAIDS” “MAIDS”

  6. heat oxygen fuel Fires • Elements of the fire triangle • Heat • Oxygen • Fuel • Classes of fires • Alfa: wood, paper (leaves ash) • Bravo: fuel, oil (flammable liquids) • Charlie: electrical • Delta: combustible metals (Mg, Na, Ti) • Safety concerns: smoke, toxic gases, heat, explosion

  7. Extinguishing Agents • Alpha: water (firemain, sprinklers) • Removes heat • Bravo: AFFF, PKP, HALON • Smothers fire • Charlie: CO2 (portable, installed) • Displaces Oxygen • Delta: water • Solid stream, fog • Jettison

  8. Firefighting Equipment • Firemain system • Receives water from sea & distributes to hoses and sprinklers • Several types of construction • Single Main (small ships) • Horizontal Loop • Vertical Loop • Sprinkler systems • Installed in magazines, turrets, weapons rooms • Can be manual or automatic

  9. Firefighting Equipment • All-purpose nozzle • Solid stream • High-velocity fog • Low-velocity fog (rotate nozzle) • Hoses • Standard • 50’ or 100’ lengths • 1.5” diameter • Collapsible

  10. Firefighting Equipment • Foam equipment • AFFF - Aqueous film-forming foam • Used for Class B (smothers fire) • Portable extinguishers • CO2: Class C or small Class A/B • AFFF: Class A or B fires • PKP: Class B fires (dry chemicals)

  11. Firefighting Equipment • Oxygen Breathing Apparatus (OBA) • Self-contained breathing protection • Generates its own oxygen • Provides 30-45 minutes of air/canister • Emergency Exit Breathing Device (EEBD) • Self-contained • Provides 15 minutes of oxygen to allow for escape • Emergency Air Breathing (EAB) • Breathing device that plugs into ship’s air • Essentially unlimited air supply • Must unplug/replug each time you move

  12. Firefighting Equipment • Naval Firefighting Thermal Imager (NFTI) • Battery-powered thermal imaging device • Provides “sight” in poor visibility (smoke) • Provides indication of hot spots • Fire Fighting Ensemble (FFE) • Flame/heat retardant • Full-body suit to prevent exposed skin • Worn in conjunction with OBA

  13. Flooding • Can occur for a number of reasons • Missile / Torpedo hit • Damaged piping • Running aground • Must not only stop flooding but also remove water that has entered ship • Drain system used • Portable submersible pumps used • Repair leak & structural damage • Use shoring, wedge, shole, strongback etc.

  14. Flooding Actions • Identify flooding location • Stop / Limit flooding • Establish boundaries • Water tight bulkheads • Piping system • Repair: shoring, patching, plugging • Dewater Spaces • Restore vital systems / equipment

  15. Priority of Dewatering • Spaces where damage cannot be repaired? • Stability (List / Trim) • Equipment: • P-250 pump • Electric submersible pump • Eductor

  16. Safety Precautions During Damage Control Operations • Flashburn • Electric Shock • Exploding Ordnance / Fuel • Heat Stress • Overcome by smoke / CO2 • Loss of lighting / Trip hazards

  17. Questions?