1 / 29

Transmittance, scraping and maximum radii for MICE STEPVI

Transmittance, scraping and maximum radii for MICE STEPVI. M. Apollonio – University of Oxford. parameters used in simulation (ICOOL) TRANSMITTANCE Define a VACUUM channel (NO ABS, NO RF) and a large aperture upstream/downstream channels 40cm + vacuum channel + 40cm + 90cm

Download Presentation

Transmittance, scraping and maximum radii for MICE STEPVI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transmittance, scraping and maximum radii for MICE STEPVI M. Apollonio – University of Oxford MICE analysis meeting - (21/09/2006)

  2. parameters used in simulation (ICOOL) TRANSMITTANCE Define a VACUUM channel (NO ABS, NO RF) and a large aperture upstream/downstream channels 40cm + vacuum channel + 40cm + 90cm Evaluate amplitude upstream/downstream and do the ratio=transmission/amplitude Max radius (effect of scraping) and cooling Use the realistic channel (real radii) Select throughoing muons Record the max radius for every z-slice Parameters used in ICOOL simulation Pz=240, 200, (170) MeV/c with no gaussian spread initial emittances: 0.1, 0.3, 0.6, 1.0, 2.0, 3.0 (cm rad) 40000 generated muons per initial emittance 128 positions along Z to study the amplitudes of the beam (Single Particle Emittance) MICE analysis meeting - (21/09/2006)

  3. Scheme for transmission study: No selection on muons Ratio between downstream and upstream particles R=40 cm R=40 cm R=90 cm Zu=-5.2 m Zd=-5.2 m T=Nd/Nu Nd Nu Scheme for max radius and cooling study: selection on muons  only throughgoing accepted Search for max value of radial distribution MICE analysis meeting - (21/09/2006)

  4. CAVEAT: • The RF is designed to work with a beam of ~200 MeV/c • When working with 240/170 MeV/c the RF config should be changed properly • I did it “by hand” changing the phase and the peak voltage • Discovered yesterday MICE analysis meeting - (21/09/2006)

  5. N.B.  RF @ 200 MeV/c: 8.74 MV/m – 90 deg 9.1 MV/m – ph.shift=30 deg P (GeV/c) Still not perfect … P (GeV/c) Pz=170 MeV/c emi=1 mm rad 8.74 MV/m – ph.shift=130 deg Z (m) Pz=240 MeV/c emi=1 mm rad 8.74 MV/m ph.shift=90 Z (m) MICE analysis meeting - (21/09/2006)

  6. beam maximum radius + cooling MICE analysis meeting - (21/09/2006)

  7. 0.1 cm rad 0.3 cm rad 0.6 cm rad 1.0 cm rad 2.0 cm rad 3.0 cm rad PZ=200 MeV/c, babs=42 cm MICE profile in ICOOL sim MICE analysis meeting - (21/09/2006)

  8. 40K m e=0.1cm rad PZ=200 MeV/c, babs=42 cm downstream e=0.3cm rad ratio heating cooling ratio MICE analysis meeting - (21/09/2006)

  9. e=0.6cm rad PZ=200 MeV/c, babs=42 cm e=1.0 cm rad MICE analysis meeting - (21/09/2006)

  10. e=2.0 cm rad PZ=200 MeV/c, babs=42 cm e=3.0 cm rad MICE analysis meeting - (21/09/2006)

  11. 0.1 cm rad 0.3 cm rad 0.6 cm rad 1.0 cm rad 2.0 cm rad 3.0 cm rad PZ=240 MeV/c, babs=42 cm MICE analysis meeting - (21/09/2006)

  12. 40K m e=0.1cm rad PZ=240 MeV/c, babs=42 cm downstream e=0.3cm rad MICE analysis meeting - (21/09/2006)

  13. e=0.6cm rad PZ=240 MeV/c, babs=42 cm e=1.0cm rad MICE analysis meeting - (21/09/2006)

  14. e=2.0cm rad PZ=240 MeV/c, babs=42 cm e=3.0cm rad MICE analysis meeting - (21/09/2006)

  15. 0.1 cm rad 0.3 cm rad 0.6 cm rad 1.0 cm rad 2.0 cm rad 3.0 cm rad PZ=170 MeV/c, babs=15 cm MICE analysis meeting - (21/09/2006)

  16. 40K m e=0.1cm rad PZ=170 MeV/c, babs=15 cm downstream e=0.3cm rad MICE analysis meeting - (21/09/2006)

  17. e=0.6cm rad PZ=170 MeV/c, babs=15 cm downstream e=1.0cm rad MICE analysis meeting - (21/09/2006)

  18. e=2.0 cm rad PZ=170 MeV/c, babs=15 cm downstream e=3.0 cm rad MICE analysis meeting - (21/09/2006)

  19. transmittance MICE analysis meeting - (21/09/2006)

  20. PZ=200 MeV/c, babs=42 cm e=0.1cm rad e=0.3cm rad MICE analysis meeting - (21/09/2006)

  21. e=0.6cm rad PZ=200 MeV/c, babs=42 cm e=1.0cm rad MICE analysis meeting - (21/09/2006)

  22. PZ=200 MeV/c, babs=42 cm e=2.0cm rad e=3.0cm rad MICE analysis meeting - (21/09/2006)

  23. !!!! 4K m !!!! PZ=170 MeV/c, babs=15 cm MICE analysis meeting - (21/09/2006)

  24. PZ=170 MeV/c, babs=15 cm MICE analysis meeting - (21/09/2006)

  25. PZ=170 MeV/c, babs=15 cm MICE analysis meeting - (21/09/2006)

  26. PZ=240 MeV/c, babs=42 cm MICE analysis meeting - (21/09/2006)

  27. PZ=240 MeV/c, babs=42 cm MICE analysis meeting - (21/09/2006)

  28. PZ=240 MeV/c, babs=42 cm MICE analysis meeting - (21/09/2006)

  29. MICE analysis meeting - (21/09/2006)

More Related