1 / 12

Artemis ESA-OSA Buy-off

Artemis ESA-OSA Buy-off. Objective. To evaluate Artemis modified machine on DEUCE EOSA assembly and whether it can achieve < 10um placement accuracy. Materials. Modified Artemis machine ( bond force 500g ) OSA and ESA Ag epoxy Techfilm 3213 LCR epoxy Optocast 3410 VM. LCR.

whitley
Download Presentation

Artemis ESA-OSA Buy-off

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Artemis ESA-OSA Buy-off

  2. Objective To evaluate Artemis modified machine on DEUCE EOSA assembly and whether it can achieve < 10um placement accuracy. Materials • Modified Artemis machine ( bond force 500g ) • OSA and ESA • Ag epoxy Techfilm 3213 • LCR epoxy Optocast 3410 VM LCR Dispensing Method Ag Epoxy Ag Epoxy LCR

  3. TX Measurement Measurement Reference Point LENS Measurement Reference Center Aperture Set-up data

  4. TX Data Distribution TX placement accuracy Passed spec of <10um placement accuracy.

  5. TX Measurement Measurement Reference Point LENS Measurement Reference Point Mesa Set-up data

  6. RX Data Distribution RX placement accuracy Passed spec of <10um placement accuracy.

  7. BLT measurement reference Side 2 Reference points Side 1 BLT measurement location 1 2 3 4 5 Five points measurement per side

  8. TX BLT Measurement RX BLT Measurement

  9. Cross-Section View Thin bond line thickness with a measurement ranging from 6-12 um

  10. Piece Part Planarity Un-even planarity of Cu block that resulted to inconsistent BLT

  11. Delamination between Cu Block and L/F Insufficient epoxy application

  12. Observation • Artemis modified machine can achieve < 10um on ESA to OSA placement accuracy. • Using 500g of bond force BLT can range from 5um to 20 um. • Inconsistent BLT was observed due to un-even planarity of piece parts. • Delamination between Cu and LF is observe due to insufficient epoxy application. ( manual dispensing )

More Related