1 / 21

Review of PETRA III Diagnostics ( five years of operational experience )

Review of PETRA III Diagnostics ( five years of operational experience ). Gero Kube for the PETRA III diagnostics team DESY Hamburg. PETRA III: present status and extension project quick glance at diagnostic systems : BPMs beam losses emittance diagnostics spurious bunches

yered
Download Presentation

Review of PETRA III Diagnostics ( five years of operational experience )

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Review of PETRA III Diagnostics(fiveyearsof operational experience) Gero Kube forthe PETRA III diagnosticsteam DESY Hamburg • PETRA III: presentstatusandextensionproject • quick glanceatdiagnosticsystems: • BPMs beam losses • emittancediagnosticsspuriousbunches • beam current (FCTs)

  2. PETRA III @ DESY • DESY site in Hamburg • PETRA III parameters circumference:2304 m energy: 6 GeV emittance: 1 nm.rad emittance coupling : 1% current: 100 mA # bunches: 40 / 960 straight sections: 9 user beamlines: 14 undulator length: 2, 5, 10 m • PETRA history • 1979 – 1986: e+e-collider(upto 23.3 GeV / beam) • 1988 – 2007: pre-acceleratorfor HERA (p @ 40 GeV, e @12 GeV) • since 2009: dedicated 3rdgeneration light source, cost-effectivesupplementto E-XFEL DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  3. PETRA Extension • P3X motivation • DORIS III shutdown in 01/2013 • → continuationofsuccessfulexperiments @ PETRA • increasenumberofuserbeamlines • → 2 new experimental halls,10 newbeamlines DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  4. PETRA Extension • P3X • longPETRA shutdownstarted 02/2014 • constructionwork in progress • back in useroperation after about 1 year • acceleratormodifications • about 50m ofthestorage ring will bemodified on eitherside • shortdipoles, nosextupoles, spaceforundulators • concretebaseinsteadofgirders • beam diagnostics • copyandpasteofexisting P3 diagnostics • → no time fornewdevelopments DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  5. Diagnostics (P3 Design Report) • PETRA III: • 228 BPMs • → 226 forOrbit • → 227 LiberaBrilliance • 6 currentmonitors • 2 Stripline-BPMs and • 2 Button-BPMs for • Multibunch Feedback • 1 Button-BPM forlongi- • tudinal Feedback • 1 Wall Gap Monitor • 1 Laser Wire Scanner • 2 BeamlinesforEmit- • tanceDiagnostics • 3 Screens • Transfer Lines: • 20 BPMs • 10 Current Monitors • 4 Wall Gap Monitors • 11 Screens • beam losses • bunchpurity not sufficient: DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  6. BPM System Overview • BPM electronics: LiberaBrilliance • BPM pickups: 8 different pickuptypes • newoctant • P3 setup • oldoctants → softwarerelease1.87 numberincreasesfor P3X P3X: upgrade to 2.09 I. Krouptchenkov et al., Proc. DIPAC 2009, Basel, TUPD03, p. 291 DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  7. BPMs: Operational Experience (1) BPM pickups • BPMs betweencantedundulatorcellsneverused • → requirementfrom MAC • → design adapted on therushfrom APS • → strong non-linearities • unphysicalbehaviourfromsingle BPM • → verticalreading not usable • → thresholdbehaviour (singlebunchcurrent) • → BPM switched off fromorbitcontrol quasi ellipticalshape: 57x7 mm buttondistance: 9.652 mm buttondiameter3.9878 mm HOMs ??? DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  8. BPMs: Operational Experience (2) BPM electronics • in principleLiberaBrillianceworksfine, but requiressomework-arounds • digital signalconditioning (DSC) algorithm • → switchingartefacts in TbTdata • → sometimesblocked DSC coefficients • → learningduring strong signallevelchangesmaycorruptcoefficients F. Schmidt-Föhre et al., Proc. DIPAC 2011, Hamburg, TUPD21, p. 350 work-around: from time totime DSC auto-learning DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  9. BPMs: Operational Experience (3) BPM electronics (cont.) • fast lifetimemeasurement via BPM sumsignal • → several BPMs showunstablesumsignal • → ESRF: temperatureandpositioninfluence • → unstable DSC I-Tech: “Angel confirmed that the DSC now works OK at Alba.” • failureof 12 V supply power • → about 10 times in 5 years, reason not yetunderstood (andinvestigated) • pile-upfromtasksystem • → uselesscronjob, compromisingtheperformance (work-around: scanning all Liberas, removingbyhand) • → problemseemstobesolvedbysoftwareupdates P3X: improved DSC algorithmwith 2.09 upgrade DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  10. X-rayoptics X-ray optics CCD Monochromator Si (311) Monochromator Si (311) CCD EmittanceDiagnostics imagingwithCompoundRefractive Lens (CRL) optics: X-raybeamline • design photonenergy • → ħω = 20 keV • verticalresolutionbroadening • → design emittance: εv = 10 pm.rad DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  11. EmittanceDiagnostics (2) setup improvements • exchangeofmonochromatorcrystal • improved CRL mounting • improveddetectorsetup • → measuredverticalemittancenearly • unaffected assumption • photonenergyslightlybelow 20 keV • → indicationfromtestmeasurementbeforeshut-down machine studies: Ultimate Storage Ring • natural beam emittance reductionof beam energy: 3 GeV(insteadof6 GeV) → emittancereductionbyfactor4 → dampingwigglercontribution: εh = 158 pm.rad • SR criticalenergy → SR spectrumbyfactor8→ ħωc = 2.6 keV X-raybeamline: 20 keV opticalmethod DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  12. SR-Interferometer @ PETRA setupin opticalhutch opticalbeamline (bunchlengthdiagnostics) Glan-Thomson polariser Ü magnificationlens visible light beampipe mirror boxes lens double slit bandpassfilter & CCD synchrotron light from bending magnet NL 50 alignmentmirror • 30 m beam transport via relayopticalsystem vertical design emittanceconfirmed DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  13. SR-Interferometer @ PETRA drawbacks USR studies • confirmationof 3 GeVhor. emittance • beamlinewithrelayoptics • → additional uncertainties (lenses) • setupblocksStreakcamerasystem • → dismountinterferometerforbunch • lengthmeasurement • spaceforonlyoneinterferometer • → modifysetupformeasurement in • othertransverse plane new optical beamline for P3X • constructionwork in progress • → status 6.5.2014 beamline originally not designed for interferometric measurements DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  14. In-Flange Fast Current Transformers 3 In-Flange FCTs installed in PETRA 1st damaged after longer operation with 40 bunches @ 1011 particles (80 mA) 2nd damaged after 40 bunch operation in 90 mA 1.5 years later • installationof (provisional) aircooling investigation from Bergoz: black residue on flanges inner surface (material seems to be cyanoacrylate impregnatingthemagneticcores) outer core wrapping: polyester tape burnt inner core wrapping: fiberglass tape blackened epoxy holding the core in the flanges browned and retracted 50Ω load: one resistor blown one end of the 20‐turn winding desoldered 20‐turn winding inductance 150μH (instead of 4.5mH initially) → relative permeability dropped from about 120000 to 4000 assumption: temperatures of much more than 100°C inside the monitor due to transient losses DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  15. In-Flange FCTs thermal simulations with CST courtesy: D. Lipka (DESY/MDI) • high thermal losses in 40 bunchmode • → transient effects • dominant mode • → leakingthrough FCT gap • → power deposition in thermally • isolatedcore • temperaturesbetween 100°C and 200°C possible • → depending on thermal coupling https://www.cst.com/Applications/Article/Heat-Load-Investigation-Of-A-PETRA-III-Toroid monitor improvements (Bergoz) • replacementofmagnetcore • → material withhigher Curie temperature • betteraircoolingofmagnetcore • installationoftemperaturesensor • → temperatureatmagnetcore • mechanicalmodifications • → betteraircirculation newmonitorsinstalledfor P3X DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  16. Beam Loss Monitoring BLM system originally not planned for PETRA operation in time resolved (40 bunch) mode • Touschek limited lifetime • → τ ≈ 1.4 h top-up operation • observationofradiationdamage • → rustatundulatormagnets • → undulatorperformancedegradation • → damagedcables installation of HERA BLM system close to IDs • monitor → 2PIN-photodiodes mounted face-to-face coincidence counting: insensitive to synchrotron radiation → up to 10 MHz count rate → dynamic range > 1E8 → 13 years successful operation at HERA DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  17. BLM Experience injected beam losses BLM1 BLM2 circulating beam losses DC current BLM rate reduced Touschek contribution life time DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  18. Loss Contribution observation of beam losses from • injected beam • circulating beam BLM system • countingoflosses • noinformationaboutenergydeposition Cherenkov (scintillator) fiber based BLMs • testinstallationat 2 IDs • studieswith beam • → onlyinjection beam losses • installationof 1mm thickscintillatingfiber BLM system with sensitivity on deposited energy observation of losses only from injected beam dominant loss contribution ??? studiescontinue after P3X commissioning DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  19. Spurious Bunches trouble-free operation until mid of 2012 suddenly user complaints • time resolvedmode (40 bunchesoperation) • → nuclearforwardscatteringexperimentswithsynchrotronradiation (i.e. Mössbauer in time domain) • observationof 16 ns time structure in NFS temporal beatpattern courtesy: H.-Ch. Wille (DESY) 2 h sample time, sp. bunch rate < 5 Hz, regularwith 16ns distance prompt at t = 0 nsmeasuredonlyforfractionof a second detector noise < 0.1 Hz spuriousbunchesat 8 nswith 10-7intensity APD noiseupto 20ns ? clean from 20 nsup DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  20. Spurious Bunches decision to build user independent spurious bunch monitor X-rayAvalanchePhoto Diode • freeportbehindmonochromatorof X-raydiagnosticbeamline • → dirtysurrounding in tunnel • → background due to X-rayfluorescence APD detector monochromatorchamber γ diffuse scatterer monitor extensively used for studies • spuriousbunches due totimingissues in injectorchain • → usersare happy withpresentsituation • monitorsuffersfromdirtysurrounding • → so faronly qualitative measurementsofbunchpuritylevel optimization still ongoing DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

  21. Summary and Outlook • statusofPETRA III and PETRA III extensionproject • operationof PETRA III diagnostics in generalstableandreliable • forsometaskswork-aroundsrequired • diagnosticsasplanned in PETRA design report was not sufficient • commissioningof P3X with additional andimproveddiagnosticsiswaiting • somefaultydevices • → FCTs • → BPMs (pickupandLiberas) • Libera DSC coefficients • opticaldiagnosticsbeamline • spuriousbunches • BLMs → hottopic: degradationof IDs many thanks …. • to all colleaguesfromthe P3 diagnosticsteam • especiallytoM.Bieler, R.Neumann, D. Nölle, D.Lipka, F.Schmidt-Föhre, H.-Ch. Wille, K.Wittenburg(DESY) • J.BergozandF.Stulle (Bergoz Instrumentation) • andfinallyspecialthankstoKees Scheidt, Philippa Gagetfororganizingtheworkshop DEELS 2014 Workshop @ ESRF, 12.05.2014 Gero Kube, DESY / MDI

More Related