1 / 35

Agenda

Agenda. Introductions – Mary Lou Fleissner, Dr.PH. NIOSH Update – Terri Pearce, Ph.D. UConn Update – Eileen Storey, M.D. Questions and Answers. August 2004 Survey 25 Sigourney Street. Terri A. Pearce, Ph.D. – Project Officer

julio
Download Presentation

Agenda

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Agenda • Introductions – Mary Lou Fleissner, Dr.PH. • NIOSH Update – Terri Pearce, Ph.D. • UConn Update – Eileen Storey, M.D. • Questions and Answers

  2. August 2004 Survey25 Sigourney Street Terri A. Pearce, Ph.D. – Project Officer National Institute for Occupational Safety and HealthDivision of Respiratory Disease Studies Field Studies Branch Morgantown, West Virginia

  3. Questions about 25 Sigourney Street • Has health improved? • Has the environment improved? • What happens next?

  4. Overall Summary • There is evidence of improvement in symptoms reported in the 12 months prior to the 2004 survey • Some occupants of 25 Sigourney Street continue to have ongoing respiratory illness • Previous water damage is likely to have contributed to the health complaints • Ongoing health surveys are required to assess the effectiveness of dampness remediation

  5. NIOSH Investigation • Union health hazard evaluation request in response to employee reports of physician-diagnosed diseases and symptoms • Became a joint request when management learned of the concerns

  6. NIOSH 2001 and 2002 Surveys • September 2001 - Health questionnaire survey offered to everyone in the building • April 2002 – Environmental sampling • June 2002 – Offered medical testing to some employees

  7. 2001 and 2002 Findings • Two to three times the expected number of employees with asthma or wheezing • Persons reporting symptoms or respiratory diagnoses frequently had abnormal lung test results or asthma medication use • Mold and endotoxin levels in dust were associated with respiratory and skin symptoms

  8. Building Repairs • Exterior repairs to correct balcony drainage, brick failure, window leaks, roof replaced • Interior replacement of water and mold damaged sheetrock • Interior repairs to bathroom core • Replacement of carpeting on some floors • Vacuuming of carpets, chairs, and partitions

  9. Has the health improved?

  10. 2004 Post-Repair Survey • 7-8 months after roof repair • 3-4 months after post-repair cleaning • Health Assessment – Questionnaires and medical testing • Building Assessment – Dust sampling and real-time monitoring

  11. Participation • 888 people in 2001 and 771 in 2004 • About 70% for both surveys 2001 2004

  12. New Diagnoses from January 2003 to August 2004 • In employees hired 2003-2004 • 1 asthma diagnosis • In employees hired before 2003 • 6 asthma diagnoses • 1 hypersensitivity pneumonitis diagnosis* • 1 sarcoidosis diagnosis * also diagnosed with asthma

  13. Respiratory Illness - 2004

  14. One or more symptoms in the last 12 months - 2004

  15. One or more symptoms each week for the last 4 weeks - 2004

  16. Non-Respiratory Symptoms - 2004In Last 12 months and 4 Weeks

  17. Summary of 2004 questionnaire survey • DRS and DSS similar for physician diagnoses and respiratory symptoms • About half of participants reported lower and non-respiratory symptoms and 30% reported skin symptoms • More upper than lower respiratory symptoms

  18. Has the percent of symptomatic employees changed between the 2001 and 2004 surveys? • We compared the results for the 481 employees who participated in both surveys

  19. Asthma-like symptoms in the last 12 months, but not in the last 4 weeks

  20. Asthma-like symptoms weekly in the last 4 weeks

  21. Have you had symptoms that you think may be related to the building? Comparison between 2001 and 2004 surveys

  22. Summary of comparison2001/2002 to 2004 • There were decreases in the percent of employees reporting symptoms in the last 12 months but not occurring in the last 4 weeks • There were no decreases in the percent of employees reporting symptoms occurring weekly in the last 4 weeks • Decrease for DRS when asked: • Have you had symptoms that you think may be related to the building?

  23. Did medical testing results change? • Lung function test results show similar relationships with symptom status in 2002 and 2004 • Positive allergy skin tests have decreased for all symptom groups • Persons with post-occupancy asthma continue to have fewer positive skin allergy tests than persons with pre-occupancy asthma

  24. Abnormal Lung Function Tests – 2002 and 2004

  25. Has the environment improved?

  26. Median Dust Levels

  27. Median Fungi Levels

  28. Median Cat Allergen Levels

  29. Have the dust levels changed? • Amounts of dust in the carpet are somewhat higher than measured in 2002 • Amounts of culturable fungi and endotoxin in floor dust are also slightly higher than in 2002 • Amounts of cat and dog allergen are lower than in 2002

  30. Real-time Monitoring • Temperature and relative humidity were within the recommended ranges • Some carbon dioxide measurements on 15th floor were above the recommended level • Water activity of some carpets could support microbial growth

  31. Have we answered the questions? • There were decreases in the percent of employees reporting symptoms in the last 12 months but not occurring in the last 4 weeks • There were no decreases in the percent of employees reporting symptoms occurring weekly in the last 4 weeks • Dust levels were similar with fungi and endotoxin levels being somewhat higher in carpets with cat and dog allergen being somewhat lower

  32. What happens next?

  33. Next Steps • August health and environmental surveys • Follow-up for new employees • Building systems evaluation

  34. Overall Summary • There is evidence of improvement in symptoms reported in the 12 months prior to the 2004 survey • Some occupants of 25 Sigourney Street continue to have ongoing respiratory illness • Previous water damage is likely to have contributed to the health complaints • Ongoing health surveys are required to assess the effectiveness of dampness remediation

  35. NIOSH - Morgantown 1-800-232-2114 Terri Pearce, Ph.D. – Project Officer