1 / 22

SIP Trunking Goldtel

Aria – iP 60. SIP Trunking Goldtel. ARIA IP - 60. What connection ? CO via GW or VoIB Card?. Introduction. This document explains the configuration that is required on ERICSSON-LG PABX systems when SIP trunks are configured using the Goldtel SIP trunk service.

Download Presentation

SIP Trunking Goldtel

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Aria – iP 60 SIP TrunkingGoldtel ARIA IP - 60 What connection ? CO via GW or VoIB Card?

  2. Introduction • This document explains the configuration that is required on ERICSSON-LG PABX systems when • SIP trunks are configured using the Goldtel SIP trunk service. • Basic call setup (Incoming & Outgoing calls) was tested with CLI (Calling Line Identification) • presentation. • Please note that this document is Service Provider specific (Goldtel Telecom) and some of the • Details below are used as examples only. • This document is only applicable to the ERICSSON-LG range of PABX systems. • Test Setup Configuration • Goldtel Service Provider Details • The following information was received from the Service Provider (Goldtel) to complete the tests: • SIP/Proxy/Registrar IP: 196.7.219.35 and 196.7.219.35 • SIP Port Number : 5060 (UDP)

  3. Slot Configuration PGM 101 - 103 Right Click If we require 8 VoIP lines then this setting = 8

  4. Numbering Plan PGM 104 - 109 What if theis is not [1]

  5. IP Settings PGM 108 Gateway IP = Router IP PABX IP Address ADSL Router IP Address The same range as the PBX 165.165.165.1 192.165.55.202

  6. CO Line Configuration PGM 140/141/143/146

  7. CO Line Configuration Co grp 1 = Voip / SIP Trunks on Slot 10 (1st Choice o/g) Telkom or other SP lines will be allocated to CO Grp2

  8. CO Line Configuration Mode 141 Mode 146 Mode 142

  9. CO Line Configuration Mode 146 CO Attr |||

  10. Station Configuration PGM 111 for all extension This parameter determines the caller id for a station when employing SIP for a call. When using SIP, the caller id is based on the CLIP/COLP (PGM 143 Flexible button 1 and 2) or the User ID defined from the SIP User ID Table index (PGM 501) entered here.{500&501 with 340} Invalid entry Message- Mode 111 FK23 = 1 Sip User ID Also Mode 231- 087 630 0 184 The last 3 digits = 184 Open Now set day & night destination ringing = 100

  11. Station Configuration PGM 111 for fax in and out going call

  12. Station Configuration PGM 114

  13. VOIP Configuration PGM 340/341 Firewall IP = WAN IP of the Router IP address of the Gateway Card VoIB ADSL Router IP Address

  14. VOIP Configuration PGM 340 SIP ATT 1 (Actually PGM 500)

  15. SIP Trunk Registration • PGM 340 SIP ATT 11 (Actually PGM 501)

  16. Net working CO line configuration PGM 322

  17. COLP Table configuration PGM 200/201

  18. Flexible DID Table PGM 231 Invalid entry Message- Mode 111 FK23 = 1 Sip User ID Error code “Cause 400” Also Mode 231- 087 630 0 184 The last 3 digits = 184 Open Now set day & night destination ringing = 100

  19. COLP Table configuration PGM 450 Flex 15 N.B. After this step please reset IP60 system

  20. Mode 200 Mode 201 Mode 231 087 6300 551 Mode 143 – DiD=2 DiD REM = 1 DiDEnblock =1 On Mode 146 – DiD RCV =3 DiD Dig = #*** #1** Mode 231 – 550 – Ring Sta 100=150